SAE AS 5419 7-2003 WIRE THERMOCOUPLE FP POLYIMIDE FP INSULATED NICKEL CHROMIUM (KP) NICKEL ALUMINUM MANGANESE (KN) THERMOCOUPLE EXTENSION NORMAL WEIGHT 260 《镍 铬 (KP) FP 聚酰亚胺 FP绝缘热电.pdf
《SAE AS 5419 7-2003 WIRE THERMOCOUPLE FP POLYIMIDE FP INSULATED NICKEL CHROMIUM (KP) NICKEL ALUMINUM MANGANESE (KN) THERMOCOUPLE EXTENSION NORMAL WEIGHT 260 《镍 铬 (KP) FP 聚酰亚胺 FP绝缘热电.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5419 7-2003 WIRE THERMOCOUPLE FP POLYIMIDE FP INSULATED NICKEL CHROMIUM (KP) NICKEL ALUMINUM MANGANESE (KN) THERMOCOUPLE EXTENSION NORMAL WEIGHT 260 《镍 铬 (KP) FP 聚酰亚胺 FP绝缘热电.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD WIRE, THERMOCOUPLE, FP/POLYIMIDE/FP INSULATED, NICKEL/ CHROMIUM (KP); NICKEL/ALUMINUM/MANGANESE (KN) THERMOCOUPLE EXTENSION, NORMAL WEIGHT, 260 C AS5419/7Copyright 2014 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval sys
2、tem or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServic
3、esae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2003-02REAFFIRMED 2014-01THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8D FEDERAL SUPPLY CLASS AS5419/7 SHEET 1 OF 8 SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technicalandengineering sciences.
4、 Theuse ofthis report is entirely voluntary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time itmay berevised, reaffirmed, stabil
5、ized, orcancelled. SAE invites yourwrittencomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS5419/7 RATIONALE AS5419/7 HAS BEEN REAFFIRMED TO COMPLY WITH THE SAE FIVE-YEAR REVIEW POLICY. Type “K” thermocou
6、ple conductors are typically used as extension leads for aerospace application. These wires are only to be used in a matched pair and procured under AS5419. Thermocouple extension wires are calibrated for use together in fabricating thermocouples. If each leg of the thermocouple extension wire is fr
7、om a different lot, recalibration of the thermocouple pair will be required.FIGURE 1 - Wire, Thermocouple, FP/Polyimide/FPComponent wire insulation system must conorm to the similar wire type designatedin Table 1 of AS5419. Manufacturers must be qualified to AS22759/86 to produce this product.TABLE
8、1 - KP Construction DetailsTABLE 1A - KP Construction Details, inch-pound UnitsAEROSPACE STANDARD AS5419/7 SHEET 2 OF 8 WIRE, THERMOCOUPLE, FP/POLYIMIDE/FP INSULATED, NICKEL/ CHROMIUM (KP); NICKEL/ALUMINUM/MANGANESE (KN) THERMOCOUPLE EXTENSION, NORMAL WEIGHT, 260 C TABLE 1B - KP Construction Details
9、, SI UnitsNotesElectromotive Force (EMF) designator = Type KPS conductor from ANSI/MC96.1 with standard limits= Type KPH conductor from ANSI/MC96.1 with special limitsExample: Size 20 standard EMF limits - WJ-20KPS-9; Size 20 special EMF limits - WJ-20KPH-9These wires comply with the sealing range r
10、equirement for firewall connectors as specified in MIL-DTL-5015, MIL-DTL-38999, and MIL-C-83723 (superseded by MIL-C-26482 and MS3470 which are inactive for new design) except that 20 awg wire is not compatible with minimum sealing range of MIL-DTL-38999 16 awg contacts and 14 awg wire is not compat
11、ible with minimum sealing range of MIL-C-83723 (superseded by MIL-C-26482 and MS3470 which are inactive for new design) and MIL-DTL-38999 12 awg contacts.TABLE 2 - KN CONSTRUCTION DETAILSTABLE 2A - KN CONSTRUCTION DETAILS, INCH-POUND UNITSAEROSPACE STANDARD AS5419/7 SHEET 3 OF 8 WIRE, THERMOCOUPLE,
12、FP/POLYIMIDE/FP INSULATED, NICKEL/ CHROMIUM (KP); NICKEL/ALUMINUM/MANGANESE (KN) THERMOCOUPLE EXTENSION, NORMAL WEIGHT, 260 C TABLE 2B - KN Construction Details, SI UnitsNotesElectromotive Force (EMF) designator = Type KNS conductor from ANSI/MC96.1 with standard limits= Type KNH conductor from ANSI
13、/MC96.1 with special limitsExample: Size 20 standard EMF limits - WJ-20KNS-5; Size 20 special EMF limits - WJ-20KNH-5These wires comply with the sealing range requirement for firewall connectors as specified in MIL-DTL-5015, MIL-DTL-38999, and MIL-C-83723 (superseded by MIL-C-26482 and MS3470 which
14、are inactive for new design) except that 20 awg wire is not compatible with minimum sealing range of MIL-DTL-38999 16 awg contacts and 14 awg wire is not compatible with minimum sealing range of MIL-C-83723 (superseded by MIL-C-26482 and MS3470 which are inactive for new design) and MIL-DTL-38999 12
15、 awg contacts.TABLE 3 - WIRE INSULATION MATERIALS1TABLE 4 - Physical Properties of FP/Polyimide/FP TapeAEROSPACE STANDARD AS5419/7 SHEET 4 OF 8 WIRE, THERMOCOUPLE, FP/POLYIMIDE/FP INSULATED, NICKEL/ CHROMIUM (KP); NICKEL/ALUMINUM/MANGANESE (KN) THERMOCOUPLE EXTENSION, NORMAL WEIGHT, 260 C TABLE 5 -
16、Tape Overlap Requirements1WIRE RATINGS AND ADDITIONAL REQUIREMENTSTEMPERATURE RATING: 260 C (500 F) max continuous conductor temperatureVOLTAGE RATING: Not applicableWET ARC PROPAGATION RESISTANCE (Test required for initial qualification only): Test in accordance with AS4373, Method 509. Measure the
17、 damage of the bundle along the axis. The wire is acceptable if the following criteria are met:1. A minimum of 67 wires pass the dielectric test2. Three wires or less fail the dielectric test in any one bundle3. Actual damage to the wire is not more than 3 in (76.2 mm) in any test bundleDRY ARC PROP
18、AGATION RESISTANCE (Test required for initial qualification only): Test in accordance with AS4373, Method 301. Measure the damage of the bundle along the axis. The wire is acceptable if the following criteria are met:1. A minimum of 67 wires pass the dielectric test2. Three wires or less fail the di
19、electric test in any one bundle3. Actual damage to the wire is not more than 3 in (76.2 mm) in any test bundleBLOCKING: 260 C 2 C (500 F 3.6 F)COLOR: In accordance with MIL-STD-104, Class 1: white and green only. Conformity of color to the limits of MIL-STD-104 shall not be required after oven expos
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS541972003WIRETHERMOCOUPLEFPPOLYIMIDEFPINSULATEDNICKELCHROMIUMKPNICKELALUMINUMMANGANESEKNTHERMOCOUPLEEXTENSIONNORMALWEIGHT260

链接地址:http://www.mydoc123.com/p-1024853.html