SAE ARP 4005C-2017 Selection and Application of Electro-Mechanical Relays for Proper Performance.pdf
《SAE ARP 4005C-2017 Selection and Application of Electro-Mechanical Relays for Proper Performance.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 4005C-2017 Selection and Application of Electro-Mechanical Relays for Proper Performance.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/ARP4005C AEROSPACE RECOMMENDED PRACTICE ARP4005 REV. C Issued 1989-04 Revised 2017-11 Supersedi
5、ng ARP4005B Selection and Application of Electro-Mechanical Relays for Proper Performance RATIONALE To update industry reference documents as needed and make minor editorial and clarifications to the ARP text. TABLE OF CONTENTS 1. SCOPE 3 2. REFERENCES 3 2.1 Applicable Documents 3 2.1.1 ECA Publicat
6、ions 3 2.1.2 IEEE Publications 3 2.2 Definitions . 3 2.2.1 Terms 3 3. APPLICATION INFORMATION 4 3.1 General 4 3.2 Relay Selection and Application . 4 3.2.1 On-Off Load Control 5 3.2.2 Transfer Operation 7 3.2.3 Multiple Relay Operation . 9 3.2.4 Coil Transient Suppression . 10 3.3 Relay Contact Conf
7、igurations . 10 3.4 Relay Misapplication . 10 3.5 Relay Application Checklist . 14 4. CONTACT LOAD CAPABILITIES . 15 4.1 Transformer Loads 16 4.2 Power Switching 16 4.3 Low Level Loads Switching . 16 4.4 Dry Circuit Switching . 16 4.5 Intermediate Current Switching . 17 4.6 Alternating Current 17 4.
8、7 Arcing and Transient Loads 17 4.8 Overload Capability Considerations 18 SAE INTERNATIONAL ARP4005C Page 2 of 23 5. COIL OPERATION DATA . 18 5.1 Operate Voltage (Coil) 18 5.1.1 Rated Voltage (Coil) 19 5.1.2 Abnormal Voltages (Coil) 19 5.2 Operational Control of Relay (Coil) . 19 5.2.1 On/Off of Squ
9、are Wave Control of Relay (Coil) 19 5.2.2 Ramp Control of Relay (Coil) 19 5.2.3 Contact Load Effect on Control Voltage (Coil) 20 5.3 Diode and Zener Diode Effects on Operation of Relay (Coil) . 20 5.4 Pickup Operation of Relay (Coil) . 20 5.5 Hold Operation of Relay (Coil) 20 5.6 Dropout Operation o
10、f Relay (Coil) . 21 5.7 Coil Voltage Cautions 21 6. HANDLING CONSIDERATIONS 21 6.1 General 21 6.2 Sources . 22 6.3 Forming or Cutting Contact Leads 22 6.4 Automatic Insertion Equipment . 22 6.5 Vapor Soldering or Surface Mounting . 22 6.6 PCB Cleaning 22 6.7 Relay Storage . 23 6.8 Mounting Pads 23 6
11、.9 Pretinning 23 7. NOTES 23 7.1 Revision Indicator 23 Figure 1A Improper circuit design 6 Figure 1B Properly designed circuit . 6 Figure 1C Improper circuit design 6 Figure 1D Properly designed circuit . 6 Figure 1E Not recommended relay open ground 7 Figure 1F Preferred design, two controlled with
12、 no adverse interaction on dropout . 7 Figure 1G Improper motor braking . 7 Figure 2 Polarity reversal, form C contacts . 8 Figure 3 Center off polarity reversal, form K contacts . 8 Figure 4 Concurrent relay operation, cascade method . 9 Figure 5 Concurrent relay operation, parallel method . 9 Figu
13、re 6 Symbols and markings for contact and coils 11 Figure 7 Contact shunting circuits . 18 SAE INTERNATIONAL ARP4005C Page 3 of 23 1. SCOPE 1.1 This SAE Aerospace Recommended Practice (ARP) provides information to guide in the selection of electromechanical relays to be used in electrical/electronic
14、 circuits for application in aerospace, ground, and shipboard systems to achieve proper performance. 1.2 Relays intended for use in aerospace industry and military applications are substantially different from those produced for industrial applications. Most industrial relays are designed so that th
15、e user can convert contact sets from NO to NC (and vice versa); add and replace auxiliary contact sets; change or replace coils; use coils on systems up to 600 V 50 to 60 Hz and expect relays to last for many operations. Typically, aerospace relays are designed to be nonrepairable with fixed contact
16、 configurations and generally for systems not exceeding 200 V and 400 Hz. These relays are generally for 28 V DC, and 115 V AC 400 Hz applications. The applicable system requirements are typically in accordance with MIL-STD-704 and RTCA-DO-160 (Radio Technical Commission for Aeronautics). These rela
17、ys are high-performance, low volume and low mass types, when compared to industrial types, and have little margin to tolerate an application or selection error. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this document to the extent specified herein. The latest i
18、ssue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this documen
19、t, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1.1 ECA Publications Available from ECA, 2500 Wilson Boulevard, Arlington, VA 22201, Tel: 703-907-8024, Engineers Relay Handbook 2.1.2 IEEE Publications Available from IEEE Operations Center, 445
20、 Hoes Lane, Piscataway, NJ 08854-4141, Tel: 732-981-0060, www.ieee.org. IEEE 315-1975 2.2 Definitions 2.2.1 Terms For a list of common terms used in the rating and design application of relays, refer to the ECA Engineers Relay Handbook. For relay definitions and terminology, refer to ANSI C83.16. SA
21、E INTERNATIONAL ARP4005C Page 4 of 23 3. APPLICATION INFORMATION 3.1 General This section contains general guideline information to assist the application engineer or circuit designer in choosing the appropriate relay. 3.2 Relay Selection and Application CAUTION: The use of any coil voltage other th
22、an the rated coil voltage may compromise the operation of the relay. Choosing the proper relay depends primarily on matching the relay to the load, power supply, and environment. Selection should be limited to items that meet the following requirements. CAUTION: When latching relays are employed in
23、a circuit, the latch and reset coils should not be pulsed simultaneously. Coils should not be pulsed with less than the nominal voltage and the pulse width should be at least three times the specified operating time of the relay. a. Contacts must be rated for the load. Current rating, type of load (
24、resistive, lamp, motor, inductive, and so forth), impedance range, voltage rating, DC or AC, frequency, single phase or polyphase, load balance, and type of switching or transfer should all be considered. Each of the following switching and transfer functions places a different requirement on the re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP4005C2017SELECTIONANDAPPLICATIONOFELECTROMECHANICALRELAYSFORPROPERPERFORMANCEPDF

链接地址:http://www.mydoc123.com/p-1022866.html