1、_ ARP378REV.CAEROSPACERECOMMENDEDPRACTICEIssued 1965-09 Revised 2006-08 Superseding ARP378B Passenger Reading Lights RATIONALEThis document has been revised to provide better guidance for the testing of passenger reading lights. INTRODUCTIONThe purpose of this SAE Aerospace Recommended Practice (ARP
2、) is to recommend minimum design criteria which will lead to adequate performance standards for passenger reading lights in aircraft. 1. SCOPE This document presents criteria for design and location of passenger reading lights in commercial aircraft. 2. APPLICABLE DOCUMENTS The following publication
3、s form a part of this document to the extent specified herein. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of thisdocument and references cited herein, the text of this document takes precedence.
4、 Nothing in this document, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1 RTCA Publications Available from Radio technical Commission for Aeronautics Inc., 1828 L Street, NW, Suite 805, Washington, DC 20036, Tel: 202-833-9339, www.rtca.org.RTCA Document
5、 No. DO-160 Environmental Conditions and Test Procedures for Airborne Electronics/Electrical Equipment and Instruments”, dated July 1984 3. DETAIL RECOMMENDATIONS 3.1 Performance 3.1.1 The reading light should provide a uniform circular or square pattern of illumination on a flat inclined reading su
6、rface located 203 mm (8 inches) above seat level. The center of the light pattern on the reading surface should be located on the fore and aft centerline of the seat and 533 mm (21 inches) from the base of the seat back (see Figure 1). The width of the light pattern should be 457 mm (18 inches). Wit
7、hin the light pattern, the minimum intensity should be 53.8 lux (5 ft-c), and the maximum intensity should be 592 lux (55 ft-c). All intensity measurements should be made with a cosine-corrected illumination meter that is parallel to a horizontal surface oriented normal to the reading light. Reaffir
8、med 2011-08SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement aris
9、ing therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2011 SAE International All rights reserved. No part of this publ
10、ication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (out
11、side USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/ARP378CCopyright SAE International Provided by IHS under license with SAENot for ResaleNo
12、 reproduction or networking permitted without license from IHS-,-,-SAE ARP378 Revision C - 2 -FIGURE 1 - RECOMMENDED READING LIGHT INSTALLATION Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP
13、378 Revision C - 3 -3.1.2 Recommended illumination levels and patterns are provided in Figure 2. An accurate rated lamp should be used for testing while operating the light at the design or system voltage which may be different from the rated lamp voltage. Accurate rated lamps are selected for their
14、 nominal filament position per specification and are calibrated to determine the voltage which produces the rated luminous flux (lumens or mean spherical candela (MSCd). 3.1.3 The reading light should be designed in such a manner so that when the reading plane is oriented normal to the light source
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP378C2006PASSENGERREADINGLIGHTS 乘客 阅读 PDF

链接地址:http://www.mydoc123.com/p-1022861.html