SAE AIR 5670-2009 Issues in Stairway Design Aboard Transport Category Airplanes《运输类飞机登机楼梯设计中的问题》.pdf
《SAE AIR 5670-2009 Issues in Stairway Design Aboard Transport Category Airplanes《运输类飞机登机楼梯设计中的问题》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 5670-2009 Issues in Stairway Design Aboard Transport Category Airplanes《运输类飞机登机楼梯设计中的问题》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、_ 6$(7HFKQLFDO6WDQGDUGV%RDUG5XOHVSURYLGHWKDW7KLVUHSRUWLVSX EOLVKHGE6$(WRDGYDQFHWKHVWDWHRIWHFKQLFDO and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, LVWKHVROHUHVSR
2、QVLELOLWRIWKHXVHU SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2016 SAE International All rights reserved. No part of this publication may be reproduced,
3、 stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-
4、0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AIR5670 AEROSPACE INFORMATION REPORT AIR5670 Issued 2009-09 Reaffirmed 2016-10 Issues in Stairway Design Aboar
5、d Transport Category Airplanes RATIONALE AIR5670 has been reaffirmed to comply with the SAE five-year review policy. 1. SCOPE 1.1 This document contains information that can be used by the air transportation industry to evaluate the design of airplane interior stairways with respect to the safety of
6、 passengers and crew in normal operating conditions and emergency evacuations. 1.2 This document addresses only design issues related to interior stairways meant for use by passengers and not stairways meant to be used exclusively by crewmembers or maintenance workers. 2. REFERENCES The following pu
7、blications for a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of the other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and refer
8、ences cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel:
9、877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. ARP503 Emergency Evacuation Illumination AIR512 Airplane Cabin Illumination ARP836 Design and Safety Criteria for Passenger Boarding Stairways. 2.2 Other Publications 2.2.1 VLTA Conference, The Netherlands, 12 August 20
10、04. A Summary. Available at http:/www.faa.gov/ats/asc/nlaweb/links.htm 2.2.2 Crashed on a partially closed runway during takeoff. Singapore Airlines Flight 006, Boeing 747-400, 9V-SPK, CKS Airport, Taoyuan, Taiwan, October 31, 2000. ASC-AAR-02-04-001. 2.2.3 Templer, J. Archea, J. specifically, there
11、 may be a need for those behind to be able to safely bypass slower evacuees. Thus, if a person is moving too slowly, or falls and blocks the exit route, those behind should be able to easily cross through openings in intermediate handrails to a path that is flowing at a higher rate. SAE INTERNATIONA
12、L AIR5670 Page 4 of 6 3.10 Emergency Illumination Compared to the minimum lighting considered adequate in public buildings, the amount recommended or allowed onboard commercial airplanes is many times lower. (See Appendix.) The minimum lighting considered adequate in public buildings for level floor
13、s is 1 ft-c (10.8 lux), and for stairways, 10 ft-c (108 lux). Measurements are to be taken at floor level (Ref. 2.2.7). The ANSI building standard (Ref. 2.2.10) states that, on stairs, luminaires shall be capable of providing 10 ft-c (108 lux) of illuminance, as measured at the center of tread surfa
14、ces and on landing surfaces within 24 inches (610 mm) of step nosings. The FAAs Human Factors Design Standard requires those same levels for emergency situations, and twice those lighting levels for normal working environments (Ref. 2.2.11, Sec. 12.2.1.8 Illumination). 3.10.1 ARP503 allows an averag
15、e level of 0.05 ft-c (0.54 lux), for both floors and stairways inside of an airplane when measured at armrest height. If measured at floor level there may be even less available light. Further, the minimum illumination at any spot along the path can be less than half of these already-low levels. Thu
16、s, ARP503 allows 20 times less light than that recommended for level floors in public buildings, and 200 times less light than that recommended for stairways. The recommended lighting level on external boarding stairs, as provided in ARP836, is 5 ft-c (53 lux) and even this may not be adequate for i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR56702009ISSUESINSTAIRWAYDESIGNABOARDTRANSPORTCATEGORYAIRPLANES 运输 飞机 登机 楼梯 设计 中的 问题 PDF

链接地址:http://www.mydoc123.com/p-1020291.html