1、 Tentative Interim Amendment NFPA1982 Standard on Personal Alert Safety Systems (PASS) 2013 Edition Reference: Various TIA 13-2 (SC 16-11-8 / TIA Log #1247) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the National Fire Protection Association has issued
2、the following Tentative Interim Amendment to NFPA 1982, Standard on Personal Alert Safety Systems (PASS), 2013 edition. The TIA was processed by the Technical Committee on Electronic Safety Equipment and the Correlating Committee on the Fire and Emergency Services Protective Clothing and Equipment,
3、and was issued by the Standards Council on December 1, 2016, with an effective date of December 21, 2016 A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the sta
4、ndard. A TIA automatically becomes a public input of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. Revise 1.1.3 to read as follows: 1.1.3* This standard shall specify the minimum requirements for the desig
5、n, performance, testing, and certification of PASS or RF PASS devices certified to an earlier edition of this standard that incorporate parts, components, and/or software to meet this edition of the standard. 2. Revise 1.3.1 to read as follows: 1.3.1 This standard shall apply to the design, performa
6、nce, testing, and certification of PASS or RF PASS devices certified to an earlier edition of this standard that incorporate replacement parts, components, and/or software to be certified to this edition of the standard. 3. Revise 4.2.8.1 to read as follows: 4.2.8.1 The certification organization an
7、d the manufacturer shall evaluate replacement parts, components, and software to determine any changes affecting the form, fit, or function of PASS or RF PASS devices certified to the 2013 or earlier editions of this standard, to permit incorporation of replacement parts, components, or software, le
8、ading to certification of devices to this edition of the standard. 4. Add a new section 4.9 to read as follows: 4.9 Manufacturers Upgrade Notification. 4.9.1 Manufacturers shall be required to provide notice of all available upgrades to the AHJ. 5. Add a new paragraph, 5.1.6.1, to read as follows: 5
9、.1.6.1 PASS or RF PASS devices certified to previous editions of this standard that have been upgraded to meet this edition shall have the following statement legibly printed. All letters shall be at least 2 mm (1/16 in.) in height. The label is not restricted to one line. The original NFPA required
10、 labeling shall not be removed or covered by the upgrade label. “PASS ALARM SOUND UPGRADED” 6. Revise 6.4.3.9 to read as follows: 6.4.3.9 The PASS annunciator shall be driven by an alarm sequence consisting of the following eight steps: (1) A Type 1 sweep (2) A silent period of 300 ms 100 ms (3) A T
11、ype 2 sweep, repeated a total of four times with a silent period of 10 ms 5 ms between each sweep (4) A silent period of 300 ms 100 ms (5) A Type 1 warble (6) A Type 2 warble (7) A Type 1 warble (8) A silent period of 600 ms 100 ms 6.4.3.9.1 Following step 8, the alarm sound shall repeat, beginning
12、immediately with step 1. 6.4.3.9.2 Type 1 Sweep. The Type 1 sweep shall be a 1 second 50 ms frequency sweep with a minimum of 100 frequency steps. The start frequency and end frequency shall be in the range of 2000 to 4000 Hz, and the end frequency shall be a minimum of 500 Hz greater than the start
13、 frequency. 6.4.3.9.3 Type 2 Sweep. The Type 2 sweep shall be a 250 ms 12.5 ms frequency sweep with a minimum of 25 frequency steps. The start frequency and end frequency shall be in the range of 2000 to 4000 Hz, and the end frequency shall be a minimum of 500 Hz greater than the start frequency. 6.
14、4.3.9.4 Type 1 Warble. The Type 1 warble shall be a 400 ms 20 ms sound that alternates between Tone A and Tone B every 10 ms 5 ms. 6.4.3.9.5 Type 2 Warble. The Type 2 warble shall be a 200 ms 10 ms sound that alternates between Tone B and Tone C every 10 ms 5 ms. 6.4.3.9.6 Tones A, B, and C shall be
15、 between 2000 Hz and 4000 Hz. 6.4.3.9.6.1 Tone A. Tone A shall be a frequency between 2300 Hz and 4000 Hz. 6.4.3.9.6.2 Tone B. Tone B shall be a frequency 100 Hz to 200 Hz below Tone A. 6.4.3.9.6.3 Tone C. Tone C shall be a frequency 200 Hz to 300 Hz below Tone B. 7. Revise 7.1.2 to read as follows:
16、 7.1.2 PASS Alarm Signal. 7.1.2.1 PASS shall be tested for the sound pressure level of the alarm signal as specified in Section 8.2, Sound Pressure Level Tests, and shall not have the alarm signal, once activated, be deactivated by the motion detector; shall have the alarm signal sound pressure leve
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA1982AMD22016STANDARDONPERSONALALERTSAFETYSYSTEMSPASSEFFECTIVEDATE12212016PDF

链接地址:http://www.mydoc123.com/p-1008426.html