NEMA MS 10-2010 DETERMINATION OF LOCAL SPECIFIC ABSORPTION RATE (SAR) IN DIAGNOSTIC MAGNETIC RESONANCE IMAGING.pdf
《NEMA MS 10-2010 DETERMINATION OF LOCAL SPECIFIC ABSORPTION RATE (SAR) IN DIAGNOSTIC MAGNETIC RESONANCE IMAGING.pdf》由会员分享,可在线阅读,更多相关《NEMA MS 10-2010 DETERMINATION OF LOCAL SPECIFIC ABSORPTION RATE (SAR) IN DIAGNOSTIC MAGNETIC RESONANCE IMAGING.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA MS 10-2010Determination of Local Specific Absorption Rate (SAR) in Diagnostic Magnetic Resonance ImagingNEMA Standards Publication MS 10-2010 Determination of Local Specific Absorption Rate (SAR) in Diagnostic Magnetic Reson
2、ance Imaging Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, VA 22209 www.nema.org 2010 by the National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convent
3、ion, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of
4、 the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document
5、 contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules t
6、o promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability
7、 for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expres
8、s or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer o
9、r sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to
10、 someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publica
11、tion may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect produ
12、cts, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. MS 10-2010 Pag
13、e i Copyright 2010 by the National Electrical Manufacturers Association. CONTENTS Page Foreword . ii Section 1 GENERAL 1 1.1 Rationale 1 1.2 Scope . 1 1.3 References 1 1.4 Definitions 2 Section 2 DETERMINING LOCAL SAR 3 2.1 Properties of the Tissue Equivalent Phantom . 3 2.2 RF Coil Loading Characte
14、ristics of the Tissue Equivalent Phantom . 6 2.3 Scan Conditions 6 2.4 Experimental Measurement . 7 Section 3 REPORTING RESULTS 9 3.1 Parameters 9 3.2 Phantom Parameters . 9 3.3 Local SAR Results . 9 3.4 Additional Data 9 3.5 Repeatability Data . 10 3.6 Sources of Error 10 Appendix THEORETICAL ESTIM
15、ATE OF LOCAL SAR . 11 MS 10-2010 Page ii Copyright 2010 by the National Electrical Manufacturers Association. Foreword This Standards Publication is classified as a NEMA Standard unless otherwise noted. It describes a measurement method for local specific absorption rate (SAR). The measurement metho
16、d requires construction of a radio frequency phantom for a given frequency and the use of radio frequency-transparent thermometry. The procedure is intended for local SAR only. The method specifically does not address whole-body SAR. This Standards Publication has been developed by the Magnetic Reso
17、nance Section of the National Electrical Manufacturers Association. Section approval of the standard does not necessarily imply that all section members voted for its approval or participated in its development. At the time it was approved, the section was composed of the following members: Computer
18、 Imaging Reference SystemsNorfolk, VA GE Healthcare, Inc.Milwaukee, WI Hitachi Medical Systems America, Inc.Twinsburg, OH Medipattern Toronto, Ontario Philips Medical Systems North AmericaBothell, WA Siemens Medical Solutions, Inc.Malvern, PA Time Medical Toronto, Ontario Toshiba America Medical Sys
19、tems Tustin, CA User needs have been considered throughout the development of this publication. Proposed or recommended revisions should be submitted to: Vice-President, Technical Services National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, VA 22209 MS 10-2010 P
20、age 1 Copyright 2010 by the National Electrical Manufacturers Association. Section 1 GENERAL 1.1 RATIONALE Local SAR is a parameter that relates to the safety of magnetic resonance (MR) scanners. The primary safety concern with both transmit surface coils and receive-only surface coils involves loca
21、l SAR Local SAR may be highest near conductors. Methods for determining local SAR are needed for ensuring safe operation of coils during MR exams. This standard does not attempt to establish relationships between SAR and body temperature. 1.2 SCOPE This document defines methods for determining the l
22、ocal specific absorption rate of diagnostic magnetic resonance imaging radio frequency coils under a specific set of conditions. This document does not address whole-body SAR. Local SAR may be determined near coil conductors, transmission lines, or any other desired region. It may be useful in some
23、cases to first do the pulse energy method described in NEMA MS-8 so that both whole-body and local SAR are measured. Heating other than radio frequency heating (such as thermal heating from surface coil blocking networks) is not addressed in this standard. 1.3 REFERENCES 1. Durney, C.H., Johnson, C.
24、C., Barber, P.W., et al, 1978, Radiofrequency radiation dosimetry handbook. USAF School of Aerospace Medicine, Report SAM-TR- 78-22, Brooks Air Force Base, Texas, 2nd ed. 2. Schenck, J.F., E.B. Boskamp, D.J. Schaefer, W.D. Barber and R.H. Vander Heiden, “Estimating Local SAR Produced by RF Transmitt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAMS102010DETERMINATIONOFLOCALSPECIFICABSORPTIONRATESARINDIAGNOSTICMAGNETICRESONANCEIMAGINGPDF

链接地址:http://www.mydoc123.com/p-994314.html