NEMA LE 5A-1999 Procedure for Determining Luminaire Efficacy Ratings for Commercial Non-Residential Downlight Luminaires (Scope for Additional Partially Replaced Information)《额外部分替.pdf
《NEMA LE 5A-1999 Procedure for Determining Luminaire Efficacy Ratings for Commercial Non-Residential Downlight Luminaires (Scope for Additional Partially Replaced Information)《额外部分替.pdf》由会员分享,可在线阅读,更多相关《NEMA LE 5A-1999 Procedure for Determining Luminaire Efficacy Ratings for Commercial Non-Residential Downlight Luminaires (Scope for Additional Partially Replaced Information)《额外部分替.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA LE 5A-1999Procedure for Determining Luminaire Efficacy Ratings for Commercial, Non-residential Downlight LuminairesPublished by: STD.NEMA LE 5A-ENGL 1999 6470247 0516235 353 NEMA STANDARDS PUBLICATION LE SA-1999 Procedure fo
2、r Determining Luminaire Efficacy Ratings for Commercial, Non-residential Downlight Luminaires National Electrical Manufacturers Association 1300 North 17th Street, Suite 1847 Rosslyn, Virginia 22209 Copyright 1999 by the National Electrical Manufacturers Association. All rights including translation
3、 into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. I Clause Section 1 1.1 1.2 1.3 Section 2 2.1 2.2 2.3 Section 3 3.1 3.2 Section 4 4.1 4.2 4.3
4、 Section 5 5.1 5.2 Section 6 6.1 6.2 Section 7 7.1 7.2 STD.NEMA LE 5A-ENGL 1999 b470247 051b23b 29T CONTENTS LE 5A-1999 Pagei Page Foreword . iii Purpose . iv GENERAL . 1 Scope 1 Referenced Documents 1 Definitions . 2 SELECTION OF COMPONENTS 5 Test Specimen-Luminaire 5 Test Specimen(s)-Compact Fluor
5、escent and HID Ballasts 5 Test Specimen(s )-Compact Fluorescent Lamps, Incandescent Lamps, HID Lamps . 5 TESTING FACILITIES AND EQUiPMENT . 7 Facilities 7 General Criteria 7 CALCULATIONS 9 Luminaire Efficacy Rating-Downlight Luminaires . 9 Calculation of Ballast Factor for Compact Fluorescent Lamps
6、9 Ballast Factor for HID Ballasts 10 PROCEDURES 11 Luminaire Efficacy Rating-Oownlight Luminaires . 11 Luminaire Category and Classification . 11 LIGHTING ENERGY COST -DOWN LIGHT LUMINAIRES 13 Comparative Yearly Energy Cost of Light . 13 Calculation: Comparative Yearly Lighting Energy Cost . 13 RECO
7、MMENDED REPORTING CATEGORIES AND FORMAT 15 Category Description 15 Recommended Reporting Format (Example Only) 15 I I STD.NEMA LE 5A-ENGL 1999 b470247 051b237 12b LE 5A-1999 Pageii AnnexA A.1 A.2 A.3 A.4 RATIONALE FOR DOWNUGHT LUMINAIRE LER. 17 Luminaire Characteristics . 17 Ballast Factors 17 Lumin
8、aire Efficiency 17 Luminaire Wattage . 17 STD.NEMA LE 5A-ENGL 1999 6470247 0516238 062 FOREWORD LE 5A-1999 Page iii This Standards Publication was developed to assist the federal government, state governments, electric utilities, and manufacturers of luminaires in performing a standardized test meth
9、od for determining the luminaire efficacy rating of incandescent, compact fluorescent, and low wattage 15Ow) high intensity discharge down light type luminaires incorporating various shielding media and various types of applicable lamps and ballasts where applicable. This Standards Publication was p
10、rompted by the need of the luminaire manufacturing industry to have a uniform method of determining energy effiCiency of their products using various components. It is not the intent of this Standards Publication to inhibit luminaire design or to impose arbitrary tolerances on any luminaire manufact
11、urer. The International Association of Lighting Designers and the Illuminating Engineering Society of North America desire to include, in the future, an additional numerical value for lighting quality to accompany the luminaire efficacy rating value. This numerical expression for lighting quality ha
12、s not yet been fully developed and is intended to be added at an appropriate time. The preparation of this Standards Publication was done by the Lighting Fixture Section, in close cooperation with the Lamp and Ballast Sections of the NEMA Lighting Systems Division. Input of users and other intereste
13、d parties has been sought and evaluated. Inquiries, comments, and proposed or recommended revisions should be submitted to the Indoor Lighting Section of NEMA by contacting: Vice President, Engineering National Electrical Manufacturers Association 1300 North 17th Street, Suite 1847 Rosslyn, Virginia
14、 22209 This standard was developed by the Lighting Fixtures Section. Section approval of the standard does not necessarily imply that all section members voted for its approval or partiCipated in its development. At the time it was approved, the Lighting Fixtures Section was composed of the followin
15、g members: American Electric Lighting-Memphis, TN Cooper Lighting Group-Elk Grove Village, IL Durolite-Fairfield, NJ GE Lighting Systems-Hendersonville, NC Holophane Corporation-Newark, OH Hubbell Lighting Inc.-Christiansburg, VA Indy Lighting, Inc.-Fishers, IN Juno Lighting, Inc.-Des Plaines, IL Li
16、ghting Corporation of America-San Leandro, CA Lithonia Lighting-Conyers, GA O-Z Gedney-Tulsa, OK Paramount Industries, I nc.-Croswell , MI Red Dot Division, L.E. Mason Co.-Boston, MA Simkar Lighting Fixture Co.-Philadelphia, PA SPI Lighting, Inc.-Mequon, WI The Genlyte Group-Union, NJ The Jones Meta
17、l Products Company-West Lafayette, OH Thomas Lighting, Inc.-Tupelo, MS I I I I I STD.NEMA LE 5A-ENGL 1999 II 6470247 0516239 TT9 II LE 5A-1999 Pageiv The purpose of this standards publication is to: PURPOSE a. Provide governmental agencies with a practical and uniform method for calculating a metric
18、 for evaluating and comparing the “energy efficiency“ of downlight luminaires. b. Create a workable and realistic number of downlight luminaire types, which can be used to evaluate energy usage. c. Organize the types of luminaires into categories which will reasonably represent the design function,
19、physical and dimensional attributes, and the photometric characteristics of the various types of high volume luminaires. d. Preserve for the luminaire manufacturers and the lighting industry the flexibility to use laboratory facilities, testing methods, and completed test data that currently exist a
20、nd are in accordance with approved industry standards. e. Establish a luminaire efficacy rating (LER) based on rated lumens per watt, in place of a standard based solely on either coefficients of utilization or luminaire efficiency. The word “rated“ is used so as not to require the use of absolute p
21、hotometry and to be able to use published rated lumen values. LER is calculated using both ballast factor, when applicable, and total input watts to establish the rated efficacy of the luminaire. (LER is given in rated lumens per watt.) NOTE-Photometric tests of luminaires that were completed prior
22、to issue date of this document may be used for calculation of LER values by substituting appropriate ballast fadors and input power values as necessary from component manufadurers reference data or from Tables A-2 and A-3. STD.NEMA LE 5A-ENGL 1999 II 6470247 0516240 710 II 1.1 SCOPE Section 1 GENERA
23、L LE 5A-1999 Page 1 This Standards Publication provides a procedure for the determination of the luminaire efficacy rating of down light luminaires under laboratory test conditions. It includes general lighting down lights for space illumination only and does not apply to specialized usage fixtures,
24、 such as accent luminaires, track luminaires, wallwashers, color filtered luminaires, aesthetically customized trims, low voltage luminaires, etc. These exceptions have intended uses that are complex and are critical to the applications that require their usage. Their effect on energy consumption ca
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMALE5A1999PROCEDUREFORDETERMININGLUMINAIREEFFICACYRATINGSFORCOMMERCIALNONRESIDENTIALDOWNLIGHTLUMINAIRESSCOPEFORADDITIONALPARTIALLYREPLACEDINFORMATION

链接地址:http://www.mydoc123.com/p-994282.html