NAVY MIL-T-81785 C-1977 TEST STATION RADIO FREQUENCY OJ-213( ) AWM-23(V)《OJ-213() AWM-23(V)电频率测试台》.pdf
《NAVY MIL-T-81785 C-1977 TEST STATION RADIO FREQUENCY OJ-213( ) AWM-23(V)《OJ-213() AWM-23(V)电频率测试台》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-81785 C-1977 TEST STATION RADIO FREQUENCY OJ-213( ) AWM-23(V)《OJ-213() AWM-23(V)电频率测试台》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-81785C 43 H 333930b 025b723 T m/ MIL-T-81785C (AS) 11 July 1977 Superseding 6 December 1974 MIL-T- 81785B (AS) MILITARY SPECIFICATION TEST STATION, RADIO FREQUENCY OJ- 2 13 ( ) /A”- 2 3 (V) This specification has been approved by the Naval Air Systems Command, Department of the Navy 1. SCOPE 1
2、.1 Scope. This specification covers the performance, design, and test requirements for the Radio Frequency Test Station (RFTS) 05-213( )/AWM-23(V) (see 6. i) 1.2 Classification. The RFTS consists of a 4-bay station and accessories as follows (see 6.4) : a. Bay No. 1: Console, Test, Radio Frequency (
3、RF), Transmitter OJ-247( )/AWM-23(V) Nomenclature Reference Paragraph Panel, Test, Noise Measurement RF Power Meter RF Voltmeter . Panel, Coolant Disconnect Mounting MT-4498( )/AiVM-23(V) (see 6.9) Drawer, Coolant Drain (see 6.9) Panel, Slave Access Power Supply PP-6770( )/AiVG-9 Power Supply PP-677
4、1( )/AiVG-9 Power Supply PP-6772( )/AWG-9 ID-1860 ( )/AWM-23(V) MX-9305( )/AWM-23(V) 3.6.1.1 3.6.1.2 3.6.1.3 3.6.1.4 3.6.1.5 . 3.6.1.6 3.6.1.7 3.6.1.7.1 3.6.1.7.2 3.6.1.7.3 Benefic ia1 comments (recommendations, addit ions, -del et ions) and any pert i- nent data which may.be of use in improving thi
5、s document should.be addressed to : Engineering Specifications and Standards Department (Code 93) Naval Air Engineering Center, Lakehurst, NJ 08733, by using self-addressed Standardi- zation Document Improvement Proposal (DD Eorm 1426) appearing at the end of this document or by letter. Provided by
6、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - MIL-T-L785C 47 W 777770b 0256730 b MIL-T-81785C (AS) b. Bay No. 2: Console, Test, Radio Frequency, Receiver 05-248( )/ AWM- 2 3 (V) (1) Microwave Swept Oscillator (2) Noise Figure Meter (3) Spectrum Analyzer (4)
7、 Switching Unit, Fault Isolation (5) Test Set, Radio Frequency Power (6) Oscillator, Radio Frequency SA- 189 3 ( ) /Aim- 2 3 (V) TS- 3276 ( ) /Aim- 23 (V) O-1633( )/AWG-9 3.6.2.1 3.6.2.2 3.6.2.3 3.6.2.4 3.6.2.5 3.6.2.5.1 c. Bay No. 3: Console, Test, Radio Frequency, Receiver-Transmitter OJ- 249 ( )
8、/Aim- 2 3 (V) (i) Oscilloscope 3.6.3.1 (2) Panel, Test, Electrical 3.6.3.2 (3) Panel, Access 3.6.3.3 (4) Comparator, Signal 3.6.3.4 (5) Dummy Load, Electrical 3.6.3.5 (6) Transducer TR-283( )/AWM-23(V) 3.6.3.6 C-9 177 ( ) /Alm- 23 (V) CM-434 ( ) /AWM-2 3 (V) DA-6 30 ( ) /AiVM- 2 3 (V) d. Bay No. 4:
9、Console, Test, Radio. Frequency 05-250( )/AWM-23(V) Panel, Power Distribution Signal Generator, RF Counter/Timer Frequency Counter Digital Multimeter Frequency Response-Analyzer Range Simulator Generator, Reference Signal Power Supply PP-6848( )/AWM-23(V) Power Supply, DC SB-3694( )/AWM-23(V) SG- 10
10、 14 ( ) /AWM-23 (V) 3.6.4.1 3.6.4.2 3.6.4.3 3.6.4.4 3.6.4.5 3.6.4.6 3.6.4.7 3.6.4.8 3.6.4.9 3.6.4.10 e. Accessories - RFTS 3.6.5 Plug-in Modules Adapters, Mounting Mounting Adapter-Modulator Mounting Adapter-XMO and Receiver Mounting Adapter-Power Supply Waveguides, Interface Extender Kit -RFTS Comm
11、ercial Items, Auxiliary Fixture, Pressure Leakage-Test 3.6.2.3 3.6.5.1 3.6.5.1.1 3.6.5.1.2 3.6.5.1.3 3.6.5.2 3.6.5.3 3.6.5.4 - -2- . -. . . . . . -. -. The fault . isolation switching unit shall provide capability to perform the fault isolation signai switching during fault isolation tests of the WR
12、As and during test station fault isolation. 3.6.2.5 Test Set, Radio Frequency Power TS-3276( )/AwM-Z3(V). The radio frequency power test set shall provide microwave switching, attenuation, termination and interconnection capabilities to connect the Oscillator, Radio Frequency O-1633( )/AWG-9, Transm
13、itter, Radar T-1224( )/AWG-9, and Receiver, Radar R-1785( )/AWG-9 WRAs to the RFTS for test purposes. shall contain a crystal mixer or use in FMR linearity measurements and another crystal mixer for modulation analysis This drawer 3.6.2.5.1 Oscillator, Radar Frequency O-1633( )/AWG-9. A radar freque
14、ncy oscillator shall be supplied and shal1,provide-a precision RF source for the RFTS and WRAs under test. 3.6.3 Console, Test, Radio Frequency, Receiver-Transmitter 05-249( )/ AWG23(V). ing The equipment of this console shall be as specified in the follow- 3.6.3.1 Oscilloscope. An oscilloscope; Hew
15、lett-Packard 181 AR with plug-in amplifier 1801A-003 andplug4n time base and delay generator 1821A, or equi- valent, shall be suppli.ed and shall provide display of waveforms. . -18- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-BI785C 49 777
16、7906 0256747 I 3.6.3.2 Panel, Test, Electrical C-9177( )/Aiv-23(V). The electrical test panel shall provide the controls, displays and switching capability to conduct functional and fault isolation tests on the WRAs assigned to the RFTS. Controls on the front panel shall be provided to command WRA P
17、ower On or Power Off, command emergency off for station power, select and .enable function- al or fault isolation tests, select and apply input signals to WRAs, select measurement instruments during test, command SSI Word Generator to provide desired word, control setting of attenuators, and control
18、 level of simulated IVRA inputs. Displays on the front panel shall be provided to display test number, test mode and status, and SSI BIT fault. 3.6.3.3 Panel, access. The access panel shall provide .cover for bay structure mounted electrical wiring. 3.6.3.4 Comparator, Signal CM-434( )/AWM-23(V). Th
19、e signal comparator shall provide: a. The capability to determine modulation frequencies and modulation indices associated with the AIM-7E and AIM-7F Missiles. Timing and gating functions necessary for operation and test of the receiver-transmitter group WRAs. The capability to measure the slope and
20、 linearity of the FMR ramp modulated X-band output of the Oscillator, Radio Fre- quency O-1633( )/AWG-9 under test. b. c. 3.6.3.5 Dummy Load, Electrical DA-630( )/AWM-23(V). The dummy load shall provide the capability to test the high power outputs of the transmitter power supplies by means of opera
21、ting into a liquid cooled load assembly. sistive load elements and associated high voltage switching relays shall be enclosed within the liquid filled assembly. Re- 3.6.3.6 Transducer, TR-283( )/AWM-23(V). The transducer shall provide the capability to provide fault and monitoring signals for detect
22、ion of inadequate cooling by means of coolant flow transducers. 3.6.4 Console, -Test, Radio Frequency 05-250( )/AWM-23(V). The equipment of this console shall be as specified below. . 3.6.4.1 Panel, Power Distribution SB-3694( )/AWM-23(V). The power dis- tribution panel shall provide the capability
23、to: . a. Control RFTS power function. b. c. d. Display RFTS malfunction indication. Indicate that input power forms are applied to the test station. Provide overload protection for the RFTS. 3.6.4.2 Signal generator. The signal generator, RF Communications Incor- porated RF-808-863-008, or equivalen
24、t, shall provide IF signals. - 19- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T- 81785C (AS) 3.6.4.3 Counterltimer. A counter/timer, Hewlett-Packard 5326B/001/011, or equivalent, shall be supplied and shall provide capability to perform the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT81785C1977TESTSTATIONRADIOFREQUENCYOJ213AWM23VOJ213AWM23V 频率 测试 PDF

链接地址:http://www.mydoc123.com/p-982862.html