1、INCH-POUNDI - E (-$W 22 December 1994 SUPERSEDING MIL-H-965D(SHIPS) 29 November 1967 (See 6.14) MILITARY SPECIFICATION HEATERS, WATER, ELECTRIC, NAVAL SHIPBOARD This specification is approved for use by the Naval Sea Systems Command (NAVSEA), Department of the Navy, and is available for use by all D
2、epartments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification describes electric, self contained, water heaters as a complete system and ensures that all system components are compatible and properly integrated with regard to size, function, and performance. The heater
3、 systems must comply with system integration requirements (see 6.9), performance, endurance, safety test procedures, shock and vibration, and standardization for installation on U.S. Naval surface ships and submarines. 1.2 Classification. The class and size of the heaters specified (see 6.2) are ide
4、ntified by the alpha/numeric designation in table I which indicates its application characteristics. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 03R
5、42, 2531 Jefferson Davis Hwy., Arlington, VA 22242-5160 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 4520 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot
6、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I. Class and size identification. Class, size designation Class A5 A 10 A 25 A 50 B5 B 10 B 25 B 50 c5 c 10 C 25 C 50 Tank capacity (gallons) A 5 10 25 50 B 5 10 25 50 C 5 10 25 50 Class A - Personnel use; 125F (ex
7、ample: showers and lavatories). Class B - Non personnel use; 160F (example: grease interception hoods and pot sanirizing sinks. Class C - Non personnel use; booster heater; 180F (example: laundry and scullery). 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications. standards, and ha
8、ndbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplem
9、ent thereto, cited in the solicitation (see 6.2). 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-965E(SH) m 999990b 1995718 814 SPECIFICATIONS MI LI TARY MIL-S - 901 - Shock Tests, H.I. (High-Impact): Shipboard Machinery, Equipment, and Syst
10、ems, Requirements for. (Naval Shipboard Use). Type, Naval Shipboard Use. MIL-E-917 - Electric Power Equipment, Basic Requirements MIL-R-2033 - Relays - Power, Electrical Specialty, Induction MIL-E-2036 - Enclosures for Electric and Electronic Equipment. MIL-C-2212 - Contactors and Controllers, Elect
11、ric Motor AC or MIL-S-4040 - Solenoid, Electrical General Specification for. MIL-P-15024 - Plates, Tags and Bands for Identification of DC, and Associated Switching Devices. Equipment. MIL-P-15024/5 - Plates, Identification. DOD-P-15328 - Primer (Wash), Pretreatment (Formula No. 117 for MIL-E-15090
12、- Enamel, Equipment, Light-Gray (Formula No. 111). MIL-W-16878 - Wire, Electrical, Insulated, General Specification Metals). (Metric) for. Insulated, 105“C, 600 Volts. Insulated, 105“C, 1000 Volts. Insulated, 105“C, 3000 Volts. Insulated, 105“C, 600 Volts, Polyamide Jacket. Insulated, 105“C, 1000 Vo
13、lts, Polyamide Jacket. Insulated, 105“C, 3000 Volts, Polyamide Jacket. Bimetallic (3-Inch and 5-Inch Dial). and Provisioned Items (Repair Parts), Packaging of. MIL-W-16878/1 - Wire, Electrical, Polyvinyl Chloride (PVC) MIL-W-16878/2 - Wire, Electrical, Polyvinyl Chloride (PVC) MIL-W-16878/3 - Wire,
14、Electrical, Polyvinyl Chloride (PVC) MIL-W-16878/17 - Wire, Electrical, Polyvinyl Chloride (PVC) MIL-W-16878/18 - Wire, Electrical, Polyvinyl Chloride (PVC) MIL-W-16878/19 - Wire, Electrical, Polyvinyl Chloride (PVC) MIL-1-17244 - Indicators, Temperature, Direct-Reading, MIL-E-17555 - Electronic and
15、 Electrical Equipment, Accessories, MIL-G-18997 - Gauge, Pressure, Dial Indicating. MIL-L-19140 - Lumber and Plywood, Fire-Retardant Treated. MIL-F-20042 - Flanges, Pipe and Bulkhead, Bronze (Silver MIL-H-22577 - Heating Elements, Electrical: Cartridge, Strip MIL-T-24270 - Thermowells for Thermomete
16、rs and Electrical Brazing) . and Tubular Type. Temperature Sensors, General Specification for. Temperature Sensors; Insertion Length - 2 Inches, Connection-Socket Weld or Socket Brazed, 3/4-Inch NPS. MIL-T-24270/1 - Thermowells for Thermometers and Electrical MIL-G-24696 - Gasket, Sheet, Non-Asbesto
17、s. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-SbSE m 7999906 L9957LS 750 m MIL-H-965E(SH) STANDARDS MILITARY MIL-STD-167-1 - Mechanical Vibrations of Shipboard Equipment (Type I - Environmental and Type II - Internally MIL-STD-248 MIL-ST
18、D-278 MIL-STD-454 MIL-STD-461 MIL-STD-462 MIL-STD-769 MIL-STD-777 MIL-STD-781 MIL-STD-889 MIL-STD-1399 Section 300 MIL-STD-1686 DOD-STD-2169 MIL-STD-45662 HANDBOOK MILITARY DOD-HDBK-263 J W h I I I I 1 I I I l I I I I 1 I I I I I I I I l l I I I I I I I 1 I I I I I I I I I 1 I I l l I I I l I I I I
19、l I I I I l 1 I I I I I I I I u a, U (d c a, W d S H Cr 9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-965E m 9799906 1995725 3.7.1.2 Heads or cover plates. Heads or cover plates shall be either cast or forged and shall be removable by bolti
20、ng at the trunk shell flange. The head or cover plate material shall be as specified in table II. 3.7.1.3 Relief valve bosses. Heaters shall be equipped with a boss for a relief valve. Connections for the relief valves boss shall be a straight threaded union in accordance with MIL-STD-777 (see 3.7.1
21、0.3). The boss shall be ground flat to accommodate an O-ring to form a tight seal. 3.7.2 Jacket. Jackets shall be used to enclose the tank and insulating material. The jacket material shall be as specified in table II. 3.7.3 Flannes. Flanges shall be welded to the tank and shall be class 150 in acco
22、rdance with ANSI B 16.9 or MIL-F-20042. 3.7.4 HeatinE elements. Heating elements shall be of the type III, tubular type, conforming to MIL-H-22577. The heating elements shall be secured to the element flanges by brazing. The element flanges shall be of the same material as the shell and shall have C
23、RES-sheathed heating elements (see 3.7.1.1). 3.7.5 End connections. End connections for the water inlet and outlet shall terminate in take down connections. The water inlet and outlet shall be supplied with flanges in accordance with ANSI B 16.5, class 150 or MIL-F-20042. Threaded pipe connections s
24、hall not be used. Heaters shall be equipped with necessary drain valves to permit complete drainage of the heater system. 3.7.6 Welding and silver brazing. Welding shall be in accordance with MIL-STD-278. In addition, qualification of welders and brazers shall be in accordance with MIL-STD-278 and 0
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILH965E1994HEATERSWATERELECTRICNAVALSHIPBOARD 海军 军舰 带电 加热器 PDF

链接地址:http://www.mydoc123.com/p-979540.html