NAVY MIL-F-7872 C (1)-1980 FIRE AND OVERHEAT WARNING SYSTEMS CONTINUOUS AIRCRAFT TEST AND INSTALLATION OF《安装及测试飞机连续消防及过热预警系统》.pdf
《NAVY MIL-F-7872 C (1)-1980 FIRE AND OVERHEAT WARNING SYSTEMS CONTINUOUS AIRCRAFT TEST AND INSTALLATION OF《安装及测试飞机连续消防及过热预警系统》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-F-7872 C (1)-1980 FIRE AND OVERHEAT WARNING SYSTEMS CONTINUOUS AIRCRAFT TEST AND INSTALLATION OF《安装及测试飞机连续消防及过热预警系统》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、- 4- 0 q 4 MIL-F-7872C (ASG) AMENDaNT 1 18 August 1980 MILITARY SPECIFICATION FIRE AND OVERHEAT WARNING SYSTEMS, CONTINUOUS, AIRCRAFT: TEST AND INSTALLATION OF This amendment forms a part of Military Speicfication MIL- F-7872C dated 18 November 1966, and is approved for use by all Departments and Ag
2、encies of the Department of Defense. 1 PAGE 1 B. 1 Paragraph 2.1 SPECIFICATIONS: Add .the following : TT-S-735 Standard Test Fluids, Hydrocarbon“ MILITARY - Delete the following: “MIL-W-5088 Wiring, Aircraft, Installation of MIL-E-5400 Electronic Equipment, Aircraft General MIL-R-6106 Relay, Electri
3、c, Aerospace, General Specification for ( i Specification for Installation and Selection of, General Specification for Preparation for Delivery“ MIL-E-7080 Electric .Equipment , Piloted Aircraft MIL-P-7936 Parts and Equipment, Aeronautcial MILITARY - Add the following: “MIL-W-5088 Wiring, Aerospace
4、Vehicle MIL-E-5400 Electronic Equipment, Airborne, General MIL-R-6 106 Relay, Electromagnetic (Including Established Specification for Reliability (ER) Types) , General Speci- f cation for and Installation of MIL-E-7080 Electric Equipment, Aircraft, Selection Bottom of page 1, add the following: .“.
5、“.1“.-“.- Beneficial comments (recommendations, additions, deletions) and any .- “._._ _“-.“I. I data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, NJ 08733, by using the
6、self-addressed Standardi- zation Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter “ “- “-“-_“_“-.-“CL Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. -. . MIL-F-7872C (L) h3 W 7777706 0236859 O - - MIL
7、-F-7872C (ASG) AMENDMENT 1 8 PAGE 2 STANDARDS MILITARY - Delete the following: “MIL-STD-411 Aircrew Station Visual Signals MIL-STD-704 Electric Power, Aircraft, Characteristics and Utilization of MS33586 Metals, Definition of Dissimilar“ MILITARY - Add the following: “MIL-STD-411 Aircrew Station Sig
8、nals MIL-STD-704 Aircraft Electric Power Characteristics. MIL-STD-794 Parts and Equipment, Procedures for MIL-STD-889 Dissimilar Metals“ Packaging and Packing of Delete paranthesized source paragraph and substitute: “(Copies of specifications, standards, drawings, and publications required by contra
9、ctors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer. 1“ - Paragraph 3.1: Delete and substitute: t “3.1 First article. When specified (see 6.2), the contractor shall furnish sample units for first article ins
10、pection and approval (see 4.3.1 and 6.4), PAGE 3 Paragraph 3.4.1, line 4 : delete “MS33586“ and subs titute “MIL-STD-889“. Paragraph 3.5.1, line 2: after “6-inch“ add “( 152.4nn)“ and after line 7: after “6-inch“ add “( 152.4mm)“ and after 2000F“ add “( 1093.3C)“ “1500F“ add 1(815.50C)“ PAGE 5 Parag
11、raph 3.5.5, line 2: after “150F to 250“ add “(65.5OC to 121.loC)“ Paragraph 3.5.5.1, line 2: after “500F“ add 11(2600C)“ add “(537.70C)“ line 4: after “4-inch“ add “(101.6mm)“; after “lOOOF“ line 5 : after “5000F“ add (26OoC)“ Paragraph 3.5.7, line 2: .delete “wore“ .and substitute “word“. line 2: a
12、fter “one half inch“ add “(12.7mm)“. 2 of6 U I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-7872C (MG) AMENDMENT 1 PAGE 6 Paragraph 3.5.13, line 3: delete “400 cycles per second“ and substitute: “400 Hertz“. - . PAGE 7 Paragraph 3.6.2.1, lin
13、e 2: after “36, 60, 120 and 180“ add “(914.4m, 1524mm, 3048m, and 4572m)“ Paragraph 3.6.3, line 2, after “20009F“ add “(1093.3C)“ PAGE 11 Paragraph 4.1, delete and substitute: “4.1 Responsibility for inspection. Unless otherwise specified in the contract, the contractor is responsible for the perfor
14、mance of all inspection requirements as specified herein. Except as otherwise specified in the contract, the contractor may use his own or any other facilities suitable for the performance of the inspection requirments specified herein, unless disapproved by the Government. The Government reserves t
15、he right to perform any of the inspection requirements set forth in this specification where such inspection is deemed necessary to assure supplies and services conform to prescribed requirements.“ Paragraph 4.2(a) : Delete and substitute (a) First article inspection“ Paragraph 4.3, delete “Preprodu
16、ction tests“ wherever it appears and substitute “First article inspection“. Paragraph 4.3.1, delete “Preproduction test“ wherever it. appears and substitute “First article inspection“. Paragraph 4.3.1.1, line 1: delete “preproduction test“ and substitute: “first article inspection“. Paragraph 4.3.2,
17、 line 1: delete “preproduction tests“ and substitute “first article inspection“. PAGE 12 Paragraph 4.3.3, delete all reference to “preproduction“ and substitute “First article“. 3 of 6 O “ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Paragraph 4.5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILF7872C11980FIREANDOVERHEATWARNINGSYSTEMSCONTINUOUSAIRCRAFTTESTANDINSTALLATIONOF 安装 测试 飞机 连续 消防

链接地址:http://www.mydoc123.com/p-979189.html