NAVY MIL-D-22612 C-1980 DETECTOR CONTAMINATED FUEL《压缩燃料探测器》.pdf
《NAVY MIL-D-22612 C-1980 DETECTOR CONTAMINATED FUEL《压缩燃料探测器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-D-22612 C-1980 DETECTOR CONTAMINATED FUEL《压缩燃料探测器》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、P t Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, New Jersey 08733, by using the self ad
2、dressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or letter. FSC 6630 Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-22612C(AS) SPECIFICATIONS MI
3、LITARY MIL-T-5624 -Turbine Fuel, Aviation, Grades JP-4 and JP-5 MIL-D-81248 -Detector Pad, Free Water MIL-S-81282 -Standard, Free Water Detector STANDARDS MIL-STD-130 -Identification Marking of U.S. Military Property MIL-STD-794 -Parts and Equipment, Procedures For Packaging and Packing of DOD-STD-1
4、399/300 -Interface Standard For Shipboard Systems Section 300 Eletrical Power, Alternating Current (Metric) (Copies of specification, standards, drawings, and publications, re- quired by suppliers in connection with specific acquisition functions should be obtained from the acquiring activity or as
5、directed by the contracting officer . ) 2.2 Other publications. The following document forms a part of this specification to the extent specified herein. Unless otherwise indi- cated, the issue in effect on date of invitation for bids or request for proposal shall apply. THE NATIONAL FIRF, PROTECTIO
6、N ASSOCIATION (NFPA) NEPA Publication 70-1978 -National Electrical Code (Application for copies should be addressed to the National Fire Protec- tion Association, 470 Atlantic Avenue, Boston, MA 02110.) (Technical society and technical association specifications and stan- dards are generally availab
7、le for reference from libraries. They are also distributed among technical groups and using Federal agencies.) 3. REQUIFWNTS 3.1 First Article. The detectors f,urnished,under this specifica- tion shall be products which have been inspected and have passed the first article inspection specified herei
8、n (see 4.3). 2 Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I MIL-D
9、-22632C bb W 9977906 0330983 W I 3.3.6 Light sensitive cell. The light sensitive cell shall be hermetically sealed against moisture and contact with jet fuel. The cell shall be mounted stationary within the filter receptacle housing. Wires entering the light sensitive cell housing shall enter the ce
10、ll housing through a horizontal side surface of the housing. 3.3.7 Test Dad (tvDe III onlv). The twe 11 detector shall be I comparison with the free water standards under ultraviolet light (3660a. 3.3.8 Vacuum receivers. The vacuum receivers shall be large enough to contain 800 milliliters of filter
11、e the receiver shall permit complete drainage of the receiver. I 3.3.9.1 Power reaurements. The detector shall be designed to oDerate I I DOD-STD-1399/300. I 3.3.9.3 Electrical components safety. Voltage and or amperage regu- I lating devices, transformers and capacitors shall be sealed with a fuel
12、resistant material to prevent contact of fuel or vapors with internal compo- nents of the devices. All other electrical components and connections shall be insulated to protect against shock to personnel. I 3.3.9.4 Motor (types II and III). The motor shall be an explosion proof type with a current l
13、imiting device to prevent overheating in the event of pump malfunction. The motor shall comply with the National Fire Protec- tion Association (NFPA) Publication: 70-1978 National Electric Code Article 500 for group D, class I, division 1 locations. 3.3.9.5 Ammeter. The ammeter shall be capable of b
14、eing read, without interpolation, in increments of 0.001 milliamperes between zero and one milliampere. The cord shall be capable of being removed from the cabinet for internal storage. 3.3.9.7 Circuit Drotection. Circuit Drotection shall consist of panel mechanical type circuit breakers, which can
15、be reset from the exterior of the cabinet. 3.3.10 Finish. -* Unless otherwise specified, painting and finishing of the detectors shall be in accordance with the suppliers standard practice, .I I I Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking per
16、mitted without license from IHS-,-,-MIL-D-22bL2C 66 W 9999906 013092 b MIL-D-22612C (AS) provided the following minimum criteria are met or exceeded: All surfaces to be painted shall have been cleaned so as to be free of all foreign matter detrimental to painting. At least one coat of primer and one
17、 top coat or equivalent shall be applied. 3.3.10.1 Color. Unless otherwise specified by the acquiring actiivty, the detectors shall be furnished in the manufacturers standard color. 3.3.11 Accessory items. 3.3.11.1 General. All components necessary for filtration and measur- ng of transmitted light
18、shall be incorporated into each detector. Compart- ments, holders, and a drawer shall be provided for storage of accessories, such as membrane filters, sampling bottle, squeeze bottle receiver assembly, forceps, tygon plastic drain tubing, two calibration (Wratten) filters, spare fuses, and spare la
19、mp. 3.3.11.2 Bottle receiver assembly. The bottle receiver assembly, pro- vided with each unit, shall consist of a bottle receiver, membrane filter holder, and a ground cable. 3.3.11.3 Sample bottle. A sample bottle with a one-liter capacity shall be provided. The bottle shall be constructed of a sh
20、atterproof materi- al which shall be resistant to kerosene. The mouth of the bottle shall be capable of being inserted into the mouth of the vacuum receiver without leakage and shall also be provided with a screw-type cap. 3.3.11.4 Wash bottle. A wash bottle with a 0.5 1it;er capacity shall be provi
21、ded. The bottle shall be constructed of a flexible shatterproof materi- al which shall be resistant to kerosene. A fixed dispensing tube type shall be included with the wash bottle. 3.3.11.5 Miscellaneous. Each detector shall also be equipped with forceps (flat tipped), 100 filters (Millipore Corpor
22、ation catalog number DAW 04700 or equal), 4 feet of tubing for drainage of receiver, 1 spare lamp, 1 spare frosted glass and 2 spare fuses (except if mechanical circuit breakers are employed). Type III detectors shall be equipped with 100 free water detector pads (47 mm) conforming to MIL-D-81248. T
23、he pads shall be supplied to the contractor as Government furnished material (see 6.4). 3.4 Performance. 3.4.1 Current output. The light sensitive cell shall have a current output of 4.8 k 0.3 microamperes per 10.8 LUX with a linearity factor of 0.80 minimum. 3.4.2 Light source. 3.4.2.1 - Light bulb
24、. The light bulb shall be easily accessible for field replacement without the use of tools. Y 5 Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I MIL-D-22b12C 66 7779906 01309A3 A I MIL-D-22612C(AS) l 3.4.2.2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILD22612C1980DETECTORCONTAMINATEDFUEL 压缩 燃料 探测器 PDF

链接地址:http://www.mydoc123.com/p-978296.html