NAVY A-A-59185-1998 HEATER HOT WATER BOOSTER ELECTRIC SINK SANITIZING (NAVAL SHIPBOARD)《海军船消毒水槽电子热水调压加热器》.pdf
《NAVY A-A-59185-1998 HEATER HOT WATER BOOSTER ELECTRIC SINK SANITIZING (NAVAL SHIPBOARD)《海军船消毒水槽电子热水调压加热器》.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-59185-1998 HEATER HOT WATER BOOSTER ELECTRIC SINK SANITIZING (NAVAL SHIPBOARD)《海军船消毒水槽电子热水调压加热器》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-59185 W 9018054 0000709 I171 W 1 1 INCH-POUND I A-A- 59 18 5 27 May 1998 COMMERCIAL ITEM DESCRIPTION HEATER, HOT WATER BOOSTER, ELECTRIC; SINK, SANITIZING (NAVAL SHIPBOARD) The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1.
2、 SCOPE This commercial item description (CID) covers hot water booster heaters that increase a sinkIs hot water temperature to not less of 180F. The heaters are intended for use in Naval shipboard food service areas for the sanitizing sink of a three-compartment or four-compartment sink washing oper
3、ation. 2. SALIENT CHARACTERISTICS 2.1 Design and construction. The heater shall have a dual-reservoir system- one to heat water, and the other to trap and collect waste. The waste reservoir shall be able to be drained without draining the heater reservoir. The heater shall be configured for secure m
4、ounting to the underside of a sink having a capacity between 51 and 80 gallons. Heaters shall be complete with all electrical wiring and plumbing connections necessary for attaching the heater to the underside of a sink. In the installed condition, the overall height of plumbing connections shall be
5、 not greater than 3 inches. Heater dimensions, exclusive of plumbing fittings, shall be not greater than 18 inches long by 9 inches wide by 13 inches high. The heater body and plumbing fittings shall be stainless steel. A quick opening discharge valve shall be provided for draining the water in the
6、sink. operation up to 200“F, and shall be readily accessible to the operator when facing the front of the heater. The heater shall have an ON-OFF switch, an integral temperature indicator to indicate when water reaches the sanitizing temperature, a signal light to indicate when the heater is in oper
7、ation, and a second signal light to indicate when the high-temperature cutout limit has been exceeded. The heater shall thermostatically control the sink water temperature to settings between 180F and 195F. shall be adjustable from the front of the heater. A high temperature cutout shall also be pro
8、vided to cut power to the heater and prevent damage in the event that there is no water in the heating reservoir, water temperature has reached 205*F, or the regular thermostat fails to operate. The high temperature cutout shall be the manual reset type. The valve shall be rated for The temperature
9、setting Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any other data .which may improve this document should be sent to: Commander, Naval Sea Systems Command, 2531 Jefferson-Davis Highway, Arlington, VA 22242-5160. FSC 7320 AMSC N/A DISTRIBUTION STATEMENT A. A
10、pproved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-9018054 0000710 993 = f A-A-59185 A-A- 59 10 5 P 2.2 Operation. Heaters shall raise the water temperature in sinks with volumes of 50 to 78 gallons
11、 from 140F to not less than 180F, and maintain it at the raised temperature for not less than 4 hours. The heater shall heat 140F water to not less than 180F in not greater than 45 minutes. 2.3 Inclined operation. The unit shall operate satisfactorily (in accordance with the requirements of this CID
12、) -with no spillage of water or waste when test-operated for 30 seconds inclined at an angle of 15 (30 when specified for submarines) each side of the vertical, in each of two vertical planes at right angles to each other. (Shipboard,requirement, see 6.2) 2.4 Environmental suitability. The unit shal
13、l be capable of withstanding ships vibration and motion. Controls, switches, moving parts, and electrical circuits shall operate under shipboard conditions without malfunction, binding, excessive looseness, or damage, when tested in accordance with MIL-STD-167/1, type I equipment. The unit shall be
14、secured to the test machine in the same manner that it will be secured on shipboard. requiFement, see 6.2) (Shipboard 2.5 Accessibility. The unit shall be physically and visually accessible from the front for operation and for normal maintenance with tools, test equipment, and replacement parts. No
15、special tools shall be required for access or parts replacement. 2.6 Electrical requirements. The unit shall operate on 440 VAC, 60 Hz, single-phase power, as defined in MIL-STD-1399, Section 300, and shall have provisions for making direct (hardwired) connections for electric power (2 conductors) a
16、nd for equipment grounding (1 conductor). All outermost metallic surfaces shall be grounded via the equipment grounding connection. The grounding resistance between any exposed metallic surfaces and the common ground point shall be not more thanO.l ohm. Electrical components, other than the hermetic
17、ally sealed motor, shall be provided in accordance with NEMA 250, Type 13 or equivalent enclosure protection. Metal parts of electrical components and enclosures shall be inherently corrosion resistant or shall be treated and processed for corrosion resistance in accordance with IEEE Standard 45. (S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA591851998HEATERHOTWATERBOOSTERELECTRICSINKSANITIZINGNAVALSHIPBOARD 海军 消毒 水槽 电子 热水 调压 加热器 PDF

链接地址:http://www.mydoc123.com/p-976360.html