NAVISTAR MPAPS F-2-2017 Fluid System Cleanliness Requirements.pdf
《NAVISTAR MPAPS F-2-2017 Fluid System Cleanliness Requirements.pdf》由会员分享,可在线阅读,更多相关《NAVISTAR MPAPS F-2-2017 Fluid System Cleanliness Requirements.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. SEPTEMBER 2017 Page 1 of 7 NAVISTAR, INC. Material, Parts, and Process Specificat
2、ions (MPAPS) NUMBER: MPAPS F-2 Former Designation: CEMS F-2 TITLE: Fluid System Cleanliness Requirements CURRENT Rev. No.: 1709 DATE: Sep. 2017 WRITTEN/REVISED BY: J. Goldschmidt APPROVED BY: R. Goluch SUPERSEDES: 1606 - June 2016 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION
3、 This specification may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory
4、 limits prior to use. 1.0 APPLICATION This specification defines test procedures and cleanliness requirements of finished components ready for assembly. Components ready for assembly have been thoroughly cleaned to remove foreign debris remaining on or inside the parts after manufacture and/or parts
5、 as-received at the assembly plant. 1.1 Restricted Chemical Substances Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the MPAPS B-50 specification. 2.0 SCOPE This specification covers general requirements, property and p
6、erformance requirements, identification, quality, packing and shipping, and source approval and quality control requirements. 3.0 CONTENTS PAGE REFERENCE DOCUMENTS 1 REQUIREMENTS 2 QUALITY 5 SOURCE APPROVAL AND QUALITY CONTROL 5 SHIPPING AND HANDELING 6 DESIGNATION ON DRAWINGS 6 TECHNICAL INFORMATIO
7、N 6 4.0 REFERENCE DOCUMENTS Unless otherwise specified, the latest issue of all referenced standards shall apply. The following standards, specifications and regulations are referenced in this specification. Quality System Standard ISO 9001 or TS-16949 EMD 991 ISO 16232-7 NAVISTAR Supplier Packing a
8、nd Shipping Std. D-13 ISO 4406 ISO 16232-10 NAVISTAR Engineering Design Std. A-16 ISO 4407 SAE J1726 NAVISTAR MPAPS B-50 ISO 16232-3 SAE J2064 CFR Title 29, Part 1910 ISO 16232-6 NUMBER: MPAPS F-2 TITLE: Fluid System Cleanliness Requirements REVISION: 1709 This document is restricted and may not be
9、sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. SEPTEMBER 2017 Page 2 of 7 5.0 REQUIREMENTS 5.1 Components The five levels of component cleanliness defined below are general
10、ly specified for the following types of applications and components: Level I: Component surfaces in contact with high pressure fuel or oil system (EMD 991 Level AA) Level II: Component surfaces in contact with filtered lubricating oil or filtered fuel (EMD 991 Level A) Level III: Internal surfaces o
11、f Intercoolers, Intake piping and component surfaces in contact with lubricating oil, inlet air, and exhaust gas (EMD 991 Level B) Level IV: HVAC A/C Hose Assemblies Level V: Component surfaces in contact with cooling water (EMD 991 Level C) Specified applications will appear as a noted requirement
12、on individual part drawings. Finished components shall meet the following cleanliness requirements as shown in the table below when tested according to the procedure defined in this specification. Components containing ferrous material shall exhibit maximum residual magnetism of 0.0005 Tesla (5 Gaus
13、s). This is low enough to preclude the adherence of fine metallic particles. Cleanliness Level Level I Level II Level III Level IV Level V Max containment weight per unit surface area 2.0 mg per 15.5 in2 (0.01 m2) up to 15 mg max per passage 2.5 mg per 15.5 in2 (0.01 m2) up to 15 mg max per passage
14、3.0 mg per 15.5 in2 (0.01 m2) up to 25 mg max per passage 3.0 mg per 15.5 in2 (0.01 m2) up to 25 mg max per passage for 5.0 mg per 15.5 in2 (0.01 m2) up to 50 mg max per passage X 0.012 in (300 Micron) 0.048 in (1200 Micron) 0.048 in (1200 Micron) 0.048 in (1200 Micron) 0.08 in (2000 Micron) Y 0.006
15、 in (150 Micron) 0.02 in (500 Micron) 0.048 in (1200 Micron) 0.048 in (1200 Micron) 0.08 in (2000 Micron) Z 0.006 in (150 Micron) 0.006 in (150 Micron) 0.008 in (200 Micron) 0.008 in (200 Micron) 0.008 in (200 Micron) Levels I, II III and V: Up to 4 particles* max per passage may exceed “X” dimensio
16、n Level IV No particle* may exceed any dimension shown All Levels: No particle* may exceed the Y or Z dimensions shown. TABLE 1: COMPONENT PARTICLE SIZE REQUIREMENTS * Particles for dimensional analysis include abrasive particles such as sand, scale, cleaning shot, weld slag and spatter, machining c
17、hips, or particles not easily broken with a probe. Maximum particle size applies to length, width, or thickness. NUMBER: MPAPS F-2 TITLE: Fluid System Cleanliness Requirements REVISION: 1709 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from
18、Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. SEPTEMBER 2017 Page 3 of 7 5.2 Method of Test The procedure and apparatus used are described in SAE J1726. A basic procedure based upon the SAE method is listed below and may be used for conv
19、enience. 5.2.1 Apparatus 5.2.1.1 Millipore Filter Assembly 5.2.1.2 Vacuum Filtering Flask 5.2.1.3 5-micron and 0.5-micron Millipore Filter paper. 5.2.1.4 Suitable Solvent, such as n-pentane, hexane, petroleum ether, or a clean wash solution at same concentration as washer using deionized water. 5.2.
20、1.5 Pressure tank with filter (similar to Millipore Model # XX6700L05) 5.2.2 Procedure: Method 1 5.2.2.1 Wash all apparatus carefully to avoid introducing extraneous contaminants. 5.2.2.2 Clean the exterior of test components as necessary to avoid introducing extraneous contaminants. 5.2.2.3 Pre-fil
21、ter the solvent to be used through a 0.5 micron Millipore filter paper. Store the filtered solvent in a clean container until it is used. 5.2.2.4 Dry a 5 micron Millipore filter (with grid) in an oven at 100C (212F) for 15 minutes. Cool to room temperature and weigh to the nearest 0.1 mg. 5.2.2.5 Th
22、oroughly flush the designated test surfaces with the filtered solvent, carefully collecting the solvent and debris into a clean beaker or container. 5.2.2.6 Pass this collected mixture through the 5-micron filter from Step 4, using the Millipore filter assembly, the vacuum filtering flask, and a vac
23、uum source. The used solvent may be discarded or refiltered through a 0.5 micron Millipore filter for reuse. 5.2.2.7 Remove the filter paper from the filter assembly. Dry in an oven at 100C (212F) for 15 minutes, cool in a desiccator, and reweigh to the nearest 0.1 mg to determine if the contaminant
24、 weight requirement is met. 5.2.2.8 Using optical magnification equipment, examine the recovered debris to determine if the particle size limitation has been met. 5.2.3 Procedure: Method 2 (ISO 16232-3) 5.2.3.1 Equip the test liquid dispenser with one or more spray nozzle(s), suitable for the surfac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSF22017FLUIDSYSTEMCLEANLINESSREQUIREMENTSPDF

链接地址:http://www.mydoc123.com/p-962950.html