《NACE 35201-2001 Technical Report on the Application and Interpretation of Data from External Coupons Used in the Evaluation of Cathodically Protected Metallic Structures (Item No 2.pdf》由会员分享,可在线阅读,更多相关《NACE 35201-2001 Technical Report on the Application and Interpretation of Data from External Coupons Used in the Evaluation of Cathodically Protected Metallic Structures (Item No 2.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Item No. 24213NACE International Publication 35201This Technical Committee Report has been preparedby NACE International Task Group 210* onCoupon TechnologyTechnical Report on the Application andInterpretation of Data from External Coupons Usedin the Evaluation of Cathodically Protected MetallicStru
2、ctures February 2001, NACE InternationalThis NACE International technical committee report represents a consensus of those individual memberswho have reviewed this document, its scope, and provisions. Its acceptance does not in any respect precludeanyone from manufacturing, marketing, purchasing, or
3、 using products, processes, or procedures not included inthis report. Nothing contained in this NACE International report is to be construed as granting any right, byimplication or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or productcovered by Letters Patent,
4、or as indemnifying or protecting anyone against liability for infringement of LettersPatent. This report should in no way be interpreted as a restriction on the use of better procedures or materialsnot discussed herein. Neither is this report intended to apply in all cases relating to the subject. U
5、npredictablecircumstances may negate the usefulness of this report in specific instances. NACE International assumes noresponsibility for the interpretation or use of this report by other parties.Users of this NACE International report are responsible for reviewing appropriate health, safety,environ
6、mental, and regulatory documents and for determining their applicability in relation to this report prior toits use. This NACE International report may not necessarily address all potential health and safety problems orenvironmental hazards associated with the use of materials, equipment, and/or ope
7、rations detailed or referredto within this report. Users of this NACE International report are also responsible for establishing appropriatehealth, safety, and environmental protection practices, in consultation with appropriate regulatory authorities ifnecessary, to achieve compliance with any exis
8、ting applicable regulatory requirements prior to the use of thisreport.CAUTIONARY NOTICE: The user is cautioned to obtain the latest edition of this report. NACEInternational reports are subject to periodic review, and may be revised or withdrawn at any time without priornotice. NACE reports are aut
9、omatically withdrawn if more than 10 years old. Purchasers of NACE Internationalreports may receive current information on all NACE International publications by contacting the NACEInternational Membership Services Department, 1440 South Creek Dr., Houston, Texas 77084-4906 (telephone+1281228-6200).
10、ForewordCoupons can be used to determine the level of corrosionprotection provided by a cathodic protection (CP) system toa buried structure, such as an operating pipeline. Structure-to-electrolyte potential measurements have long been usedas the basis for assessing cathodic protection levels andcom
11、pliance with CP criteria. It is well known that a voltage(IR) drop exists in the soil or across the coating, and thatthis IR drop can produce an error in the interpretation of thestructure-to-electrolyte potential measurement. This voltagedrop can be a function of reference electrode placement,soil
12、resistivity, burial depth of the structure, coatingcondition, and the amount of CP current applied.CP coupons have been used since the 1930s by several ofthe pioneers of the corrosion-control industry, both in NorthAmerica and in Europe. Over the last two decades, the useof CP coupons has been redis
13、covered as a practicalmethod to determine the level of polarization of a buriedstructure and to confirm the voltage drop in a potentialmeasurement. Acceptance of CP coupon technology isslowly occurring. Research sponsored by the pipelineindustry has explored the use of CP coupons and hashelped valid
14、ate the use of this technology. The purpose ofthis technical committee report is to provide an alternative tothe conventional evaluation of the effectiveness of a CPsystem.This NACE technical committee report was prepared byTask Group 210 (formerly T-10A-3a) on CouponTechnology. Task Group 210 is ad
15、ministered by SpecificTechnology Group (STG) 35 on Pipelines, Tanks, and WellCasings and is sponsored by STG 05 on Cathodic/AnodicProtection. This report is issued under the auspices of STG35 on Pipelines, Tanks, and Well Casings._*Chairman Kevin T. Parker, CC Technologies, Inc., Dublin, Ohio.NACE I
16、nternational2GeneralA CP coupon is used to simulate coating defects (holidays)on the structure being evaluated. The CP coupon isinstalled near the structure and then connected to it throughan aboveground test station. This allows the CP coupon tobe connected to the CP system on the structure, thussi
17、mulating a holiday in the coating. The CP coupon canthen be disconnected from the circuit during periodic testing,and an instant-off potential measured. The CP coupon canthen continue to be monitored and the depolarizationmeasured. These measurements approximate thepolarized and the depolarized pote
18、ntial of the structure inthe vicinity of the CP coupon and allow the operator tocalculate the IR drop. A second “free-corroding” nativecoupon has sometimes been installed at the same locationas the CP coupon to measure the native potential of thecoupon.NACE Standard RP01691states, “Voltage (IR) drop
19、s otherthan those across the structure-to-electrolyte boundarymust be considered. . .” in order to assess the effectivenessof a CP system using fixed potential measurements.Several methods are used to evaluate the IR drop valueand thus the effectiveness of CP systems: Minimizing the distance between
20、 the referenceelectrode and the surface of the structure; Measuring the potential when the current flow isinterrupted (the “instant-off” potential); or Installing CP coupons in the vicinity of thestructure to replicate a coating holiday.All of these methods have their advantages anddisadvantages. NA
21、CE Standard TM04972includes some ofthe methods used to satisfy NACE Standard RP0169.CP coupons have several advantages. IR-drop error-reduced potentials can be obtained without interruptingmultiple CP sources. CP coupons can also be used onburied structures with direct-connected galvanic anodes,whic
22、h cannot be interrupted. Using CP coupons,depolarization testing can be performed without de-energizing the CP system. An additional advantage is theability to record interference-reduced structure potentials onstructures affected by stray currents.A disadvantage of using CP coupons is the possibili
23、ty ofdiscrepancy between the polarized potential of the structureand that of the CP coupon. Because the CP couponrepresents a holiday of similar size on the structure, thepolarized potential of the CP coupon does not alwaysduplicate the polarized potential of the structure at the samelocation. The h
24、oliday location (as observed by the polarizedpotential of the structure measured at grade) is notnecessarily at the CP coupon location, and can be at alocation some distance away.An additional complication in measuring a structurepotential is the effect of IR drops from uninterruptablecurrent source
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACE352012001TECHNICALREPORTONTHEAPPLICATIONANDINTERPRETATIONOFDATAFROMEXTERNALCOUPONSUSEDINTHEEVALUATIONOFCATHODICALLYPROTECTEDMETALLICSTRUCTURESITEMNO2PDF

链接地址:http://www.mydoc123.com/p-835732.html