JEDEC JESD22-A104E-2014 Temperature Cycling.pdf
《JEDEC JESD22-A104E-2014 Temperature Cycling.pdf》由会员分享,可在线阅读,更多相关《JEDEC JESD22-A104E-2014 Temperature Cycling.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、JEDEC STANDARD Temperature Cycling JESD22-A104E (Revision of JESD22-A104D, March 2009) OCTOBER 2014 JEDEC SOLID STATE TECHNOLOGY ASSOCIATION NOTICE JEDEC standards and publications contain material that has been prepared, reviewed, and approved through the JEDEC Board of Directors level and subseque
2、ntly reviewed and approved by the JEDEC legal counsel. JEDEC standards and publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in se
3、lecting and obtaining with minimum delay the proper product for use by those other than JEDEC members, whether the standard is to be used either domestically or internationally. JEDEC standards and publications are adopted without regard to whether or not their adoption may involve patents or articl
4、es, materials, or processes. By such action JEDEC does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the JEDEC standards or publications. The information included in JEDEC standards and publications represents a sound approach to product
5、 specification and application, principally from the solid state device manufacturer viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or publication may be further processed and ultimately become an ANSI standard. No claims to be in conformance with this standar
6、d may be made unless all requirements stated in the standard are met. Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication should be addressed to JEDEC at the address below, or refer to www.jedec.org under Standards and Documents for alternative contact
7、information. Published by JEDEC Solid State Technology Association 2013 3103 North 10th Street Suite 240 South Arlington, VA 22201-2107 This document may be downloaded free of charge; however JEDEC retains the copyright on this material. By downloading this file the individual agrees not to charge f
8、or or resell the resulting material. PRICE: Contact JEDEC Printed in the U.S.A. All rights reserved PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by JEDEC and may not be reproduced without permission. For information, contact: JEDEC Solid State Technology Association 3103 North 10th Str
9、eet Suite 240 South Arlington, VA 22201-2107 or refer to www.jedec.org under Standards-Documents/Copyright Information. JEDEC Standard No. 22-A104E Page 1 Test Method A104E (Revision of Test Method A104D) TEST METHOD A104E TEMPERATURE CYCLING (From Board Ballot JCB-00-16, JCB-05-82, JCB-09-20, and J
10、CB-14-45, formulated under the cognizance of the JC-14.1 Committee on Reliability Test Methods for Packaged Devices.) 1 Scope This standard applies to single-, dual- and triple-chamber temperature cycling and covers component and solder interconnection testing. It should be noted that this standard
11、does not cover or apply to thermal shock chambers. In single chamber cycling, the load is placed in a stationary chamber and is heated or cooled by introducing hot or cold air into the chamber. In dual-chamber cycling, the load is placed on a moving platform that shuttles between stationary chambers
12、 maintained at fixed temperatures. In triple-chamber temperature cycling there are three chambers and the load is moved between them. This test is conducted to determine the ability of components and solder interconnects to withstand mechanical stresses induced by alternating high- and low-temperatu
13、re extremes. Permanent changes in electrical and/or physical characteristics can result from these mechanical stresses. 2 Terms and definitions 2.1 load: The sample(s) and associated fixtures (trays, racks, etc.) in the chamber during the test. 2.2 working zone: The volume in the chamber(s) in which
14、 the temperature of the load is controlled within the specified conditions. 2.3 sample temperature (Ts): The temperature of the samples during temperature cycling, as measured by thermocouples or equivalent temperature measurement apparatus affixed to, or imbedded in, their bodies. NOTE The thermoco
15、uple, or equivalent temperature measurement apparatus, attachment method used should ensure that the entire mass of the sample(s) is reaching the temperature extremes and the soak requirements. 2.4 maximum sample temperature: (Ts(max): The maximum temperature experienced by the sample(s) as measured
16、 by thermocouples, per 3.3. 2.5 minimum sample temperature: (Ts(min): The minimum temperature experienced by the sample(s) as measured by thermocouples, per 3.3. JEDEC Standard No. 22-A104E Page 2 Test Method A104E (Revision of Test Method A104D) 2 Terms and definitions (contd) 2.6 load transfer tim
17、e: The time it takes to physically transfer the load from one temperature chamber and introduce it into the other. Load transfer applies to dual and triple chamber cycling. 2.7 maximum load: The largest load that can be placed in the chamber and still meet the specified temperature cycling requireme
18、nts as verified by thermocouples, per 3.3. 2.8 nominal T: The difference between nominal Ts(max)and nominal Ts(min)for the Temperature Cycling Test Condition; see Table 1. 2.9 soak time: The total time the sample temperature is within a specified range of each nominal Ts(max)and nominal Ts(min). Thi
19、s range is defined as the time Tsis at 5 C to +10 C /+15 C (dependent on the Test Condition tolerance) of Ts(max)nominal for the upper end of the cycle and the time Ts is +5 C to 10 C of Ts(min)nominal for the lower end of the cycle. 2.10 soak temperature: The temperature range that is 5 C to +10/+1
20、5 C (dependent on the Test Condition tolerance) of Ts(max)nominal and +5 C to 10 C of Ts(min)nominal. 2.11 (temperature) cycle time: The time interval between one high-temperature extreme to the next, or from one low-temperature extreme to the next, for a given sample; see Figure 1. 2.12 ramp rate:
21、The rate of temperature increase or decrease per unit of time for the sample(s). NOTE 1 Ramp rate should be measured for the linear portion of the profile curve, which is generally the range between 10% and 90% of the test condition temperature range; see points a and b in Figure 1. NOTE 2 Ramp rate
22、 can be load dependent and should be verified for the load being tested. 2.13 test conditions: The various temperature cycle range options listed in Table 1. 2.14 soak mode: The categorization nomenclature that defines minimum soak time at soak temperature(max) see Table 1. 2.16 nominal Ts(min): The
23、 temperature of the sample required to meet the minimum nominal temperature for a specific test condition; see Table 1. JEDEC Standard No. 22-A104E Page 3 Test Method A104E (Revision of Test Method A104D) 3 Reference documents JEP 140, Beaded Thermocouple Measurement of Semiconductor Packages. JEP 1
24、53, Characterization and Monitoring of thermal Stress Test Oven Temperatures. JESD94, Application Specific Qualification using Knowledge Based Test Methodology. IPC-SM-785, Guidelines for Accelerated Reliability Testing of Surface Mount Solder Attachments. 4 Apparatus The chamber(s) used shall be ca
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJESD22A104E2014TEMPERATURECYCLINGPDF