ITU-T K 57-2003 Protection measures for radio base stations sited on power line towers SERIES K PROTECTION AGAINST INTERFERENCE (Study Group 5)《输电线塔上的无线基站的保护措施 系列K 抗干扰防护(研究组5)》.pdf
《ITU-T K 57-2003 Protection measures for radio base stations sited on power line towers SERIES K PROTECTION AGAINST INTERFERENCE (Study Group 5)《输电线塔上的无线基站的保护措施 系列K 抗干扰防护(研究组5)》.pdf》由会员分享,可在线阅读,更多相关《ITU-T K 57-2003 Protection measures for radio base stations sited on power line towers SERIES K PROTECTION AGAINST INTERFERENCE (Study Group 5)《输电线塔上的无线基站的保护措施 系列K 抗干扰防护(研究组5)》.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、 INTERNATIONAL TELECOMMUNICATION UNION ITU-T K.57TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (09/2003) SERIES K: PROTECTION AGAINST INTERFERENCE Protection measures for radio base stations sited on power line towers ITU-T Recommendation K.57 ITU-T Rec. K.57 (09/2003) i ITU-T Recommendation K.57
2、Protection measures for radio base stations sited on power line towers Summary This Recommendation specifies measures to be taken with respect to safety and risk of damage to equipment through earth potential rise, when power line towers are used for locating radio base stations. It also considers t
3、he special lightning protection scheme, which is needed for this type of installation. This is of special concern when power is fed from the low-voltage network, which is the most common situation. Different options are described. Three appendices are attached: Appendix I, titled “Guide on the coord
4、ination of the isolation level required for the power supply circuit and the potential rise of power line towers“, gives information on how to determine the required isolation voltage level due to the EPR at an earth fault in the tower. In Appendix II, titled “Guide on the LV feeding arrangement“, m
5、ore details on the low-voltage feeding options are given. Finally, Appendix III, titled “Characterization and control of the EPR zone of tower earthing and estimation of the minimum length of the junction section“, presents simple calculations for estimation of the EPR for the determination of the l
6、ength of the so-called junction cable. It also shows graphs of the EPR and touch voltage when grading frame earths around the equipment cabinet are installed. Source ITU-T Recommendation K.57 was approved by ITU-T Study Group 5 (2001-2004) under the ITU-T Recommendation A.8 procedure on 6 September
7、2003. ii ITU-T Rec. K.57 (09/2003) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical,
8、operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in tur
9、n, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE
10、 In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.
11、g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not s
12、uggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the e
13、vidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, whic
14、h may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database. ITU 2004 All rights reserved. No part of this publication may be reproduced, by any means wh
15、atsoever, without the prior written permission of ITU. ITU-T Rec. K.57 (09/2003) iii CONTENTS Page 1 Scope 1 2 References. 1 3 Definitions and abbreviations. 1 3.1 Definitions 1 3.2 Abbreviations . 2 4 General 2 4.1 Earth fault characterization of directly earthed power systems 3 4.2 Earth fault cha
16、racterization of non-directly earthed power systems 3 4.3 Earth potential rise (EPR). 3 5 Power supply 4 5.1 Feeding from the LV network 4 5.2 Feeding from a MV network 8 5.3 Feeding from the HV line. 8 6 Requirements on the antenna system 8 7 Telecommunication cables . 9 8 Earthing arrangements 9 9
17、 Installation and maintenance 9 10 Examples of installations 10 Appendix I Guide on the coordination of the isolation level required for power supply circuit and the potential rise of power line towers 12 I.1 Scope of the investigation 12 I.2 Investigated options, parameters 12 I.3 Analysis of the r
18、esults 15 I.4 Estimation of the required isolation level. 29 Appendix II Guide on the LV feeding arrangement . 33 II.1 LV feeding arrangement. 33 II.2 Protection principles. 34 II.3 Selection of the design values for the protection 36 II.4 Options for the feeding of multiple RBSs 37 Appendix III Cha
19、racterization and control of the EPR zone of tower earthing and estimation of the minimum length of the junction section . 40 III.1 Characterization of the zone of EPR of the tower earthing 40 III.2 Control of touch and step voltages by potential PGE. 44 III.3 Estimation of minimum length values 54
20、ITU-T Rec. K.57 (09/2003) 1ITU-T Recommendation K.57 Protection measures for radio base stations sited on power line towers 1 Scope This Recommendation specifies measures to be taken with respect to safety and risk of damage to equipment through earth potential rise, when power line towers are used
21、for locating radio base stations. Special arrangements for lightning protection at these installations are also covered. It considers both the power feeding and the connection to the telecommunication network. It also mentions the risk of disturbances to the transmitting antenna. Lightning protectio
22、n of radio base stations is treated in ITU-T Rec. K.56. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Rec
23、ommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regular
24、ly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T Recommendation K.8 (1988), Separation in the soil between telecommunication cables and earthing system of power facilities. ITU-T Recommendation K.3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTK572003PROTECTIONMEASURESFORRADIOBASESTATIONSSITEDONPOWERLINETOWERSSERIESKPROTECTIONAGAINSTINTERFERENCESTUDYGROUP5

链接地址:http://www.mydoc123.com/p-799269.html