1、. c-1 Manufacturing Standards E ELECTRICAL MANuFAC!lTJRING STANDARD SAFETP OF MACHINERY- ELEC!l!RICALEQUIEMENTOFMACHINES FORD USER REQUIREMENTS TO EURONORM EN 60204-l: 1992 This Ford Manufacturing Standard shall be read in conjunction with the National versions of the European Standard EN 60204-1:19
2、92, which together with this Ford Manufacturing Standard describes all the requirements for the ?. Guarding is impractical or, Short movements are required, for example clamping fixtures, piercing or clinching tools etc., or, cl - Manual movements of inching/jogging movements are required. Use of tw
3、o-hand control shall only be allowed with prior approval of the appropriate Plant safety representative. Where approved for use, two-hand control shall be so arranged placed and protected, that they cannot be operated unintentionally or be easily defeated. It shall be impossible for the operator to
4、actuate both controls with one hand or one hand and another part of the body. Bridging both buttons with a tool shall not be easily possible. U-EXOOI Safety of Machinery - Page 6 of 14 Electrical Equipment of Machines September 1994 l m Manufacturing Standards E The distance of the controls from the
5、 nearest dangerous movements (point of danger) must be such that movements stop before the operator can reach them. The minimum safe distance from the point of danger shall be provided based on the calculation :- S = v.t where : v = 1.6 m/s (metres/second) : t= braking time (seconds) This safety dis
6、tance shall also apply to movable two-hand controls. . :. The timing relay shall be of a fixed delay of 0.5 seconds, or, if adjustable, shall have a maximum setting of 0.5 seconds. Where more than one operator works on the same machine which is safeguarded by two-hand controls, each operator shall b
7、e provided with two-hand controls. the concurrent operation of all separate two-hand-start stations shall be necessary to obtain a start command. Arrangements to enable lock-out of control stations if the number of operators is reduced shall be carried out in a fail-safe manner. Power presses that r
8、equire more than one two-hand control station, have to comply with other special safety requirements. (eg. lock-out proceedure for two-hand control) Only two-hand-start-relays shall be used to control this operation. Where National legislation calls for specially approved two-hand-start safety relay
9、s to be used, the machine shall be supplied with the appropriate safety certificates which cover the relays provided. 9.3.5 Reverse current braking, DC. injection braking and braking via drive controllers alone shall only be used if no danger to personnel or machines arises. 9.3.6 The safety related
10、 parts of a control system shall be designed in a way that the machine is safe during all intended use, forseeable misuse and forseeable human mistakes if faults occur. The selecting of safety measures shall be determined by a provable risk assessment according to EN 954. 9.4.1.4 Circuits switched o
11、ff for personnal protection shall not be connected on the isolated side to any other circuits, to avoid possible faults bypassing safety functions over parallel paths. 9.4.3.1 All control circuits shall have one side of the circuit connected to the protective bonding conductor. (see 8.4 ) This requi
12、rement also applies to the power supplies for programmable controller input and output groups. September 1994 Safety of Machinery - Electrical Equipment of Machines U-EXOOl Page 7 of 14 Manufacturing Standards 10.1 Command/control devices, such as motion sensors or manually operated control equipmen
13、t, shall not be used for direct control of magnets, clutches and brakes. Exceptions are the switching functions of safety circuits . The use of safety override switches shall only be used with the approval of the Ford specifying engineer. 10.1.1 Operator control devices shall be so placed that all m
14、ovements of the machine remain visible, if necessary, several control stations shall be provided 10.1.3 In the case of position and proximity switches, valves etc. the actuated condition shall be indicated by an LED on the unit or on the connector (excluding safety limit switches) Wherever possible
15、the electrical connections should be plugable. (this shall exclude safety switches) With the exception of safety circuits, sensing with proximity switches is preferred. 10.3.1 Operator indicator lights and displays shall be provided with a grouped means to test their functions using a single button
16、on each operator station or other interface point. Alternative means of indication for machine status and fault diagnostic information can be as follows :- * Indicator lamps * Alphanumeric text display * Visual display units * EDDI to the Ford specification The method shall be agreed with the Ford S
17、pecifying Engineer 11.2 Inputs and Outputs of programmable devices should be potential free, voltages being derived from the control circuit supply and not from the programmable controller. 11.2.1 Digital inputs shall only be loaded by a single input device eg. push button, position switch etc. 12.2
18、.1 All Input and Output devices shall be short circuit protected Electronic devices with short circuit protected outputs shall be functional after removal of the short circuit. Removal of the short circuit shall not cause hazards to personnel, machines or products. The input/output modules shall be
19、removable without disconnection of the field wiring. Input/output modules shall be located as close as possible to the functional devices controlled and interconnecting wiring shall be arranged to facilitate this. U-EXOOl Safety of Machinery - Page 8 of 14 September Electrical Equipment of Machines
20、1994 o c-3 Manufacturing Standards E 12.3.1 12.3.2 12.3.3 12.3.4 Terminal reference and control device numbering shall be in accordance with the Input/Output addresses. Consideration shall be given to the provision of spare Input and Output capacity with the agreement of the Ford Specifying Engineer
21、. Configuration and installation of the programmable equipment shall be in accordance with the original manufacturers instructions. The Programmable controller internal watchdog device shall be arranged to switch off all hazardous machine functions in a controlled safe manner in the event of a malfu
22、nction within the Programmma ble controller. It is preferred that programme software shall be stored on non-volatile memory. In any event, data in programmable memory shall not be lost as a result of power failure. The Programmable controller executive software shall not be modified by the machine b
23、uilder or overwritten by the user programme. Suitable power sockets and data connection points for the programming equipment shall be provided within the enclosures of all the programmable devices and at other appropriate points. Memory capacities of the program memories (for user programmes) shall
24、be selected so that standard machines have at least lo%, special machines at least 20% spare capacity. The connection and disconnection of programming equipment shall be possible during machine operation and without disconnection of diagnostic displays. The user software shall be clear and serviceab
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDUEX0011994SAFETYOFMACHINERYELECTRICALEQUIPMENTOFMACHINES 机械 安全性 机器 电气设备 PDF

链接地址:http://www.mydoc123.com/p-748264.html