FORD FLTM BJ 124-1-2001 ENGINE OIL FILTERABILITY TEST (Replaces FLTM BJ 024-01).pdf
《FORD FLTM BJ 124-1-2001 ENGINE OIL FILTERABILITY TEST (Replaces FLTM BJ 024-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BJ 124-1-2001 ENGINE OIL FILTERABILITY TEST (Replaces FLTM BJ 024-01).pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BJ 124-01 Date Action Revisions 2001 07 25 Revised Editorial no technical change A. Cockman 1992 02 03 Printed copies are uncontrolled Page 1 of 8 Copyright 2001, Ford Global Technologies, Inc. ENGINE OIL FILTERABILITY TEST Application This test is designed to determine
2、the tendency of an oil to form a precipitate which can plug an oil filter. It simulates a problem which can be encountered in a new engine run for a short period of time followed by a long period of storage with some water and blowby condensate in the oil. The procedure involves testing an oil as-re
3、ceived (termed “new oil“) and then after the oil has been subjected to hot and cold environments in the presence of moisture (termed “environmentalized“). Apparatus Required Blender Base Blender with low speed of 1800 rpm +/- 10 % unloaded. Waring Model 7011 two-speed blender base or equivalent. Con
4、tainer Waring MC-3, 50 - 250 m “mini-container“ or equivalent. Syringe 1000 microlitre. Glass Jar 60 mL glass jars. Oven Oven with fan and capable of maintaining 70 +/- 2 C. Thelco Model 18 or equivalent. Buret 25 mL (refer to Note 1). Filter Holder Millipore XX30-012-00; effective filters are 0.7 c
5、m2 (refer to Note 2). Stopwatch Capable of timing sequential events. Note 1: To ensure that there are no restrictions to the oil flow in the buret, a PTFE (Teflon) stopcock with a minimum opening of 1.8 mm must be used. Likewise, the tip of the buret must have an opening of 1.8 mm or greater. FORD L
6、ABORATORY TEST METHOD BJ 124-01 Page 2 of 8 Copyright 2001, Ford Global Technologies, Inc. Note 2: The effective filter area for each new filter holder is calculated by measuring the flow times and calculating the average flow time for a reference fluid (FR No. 1) of known average flowrate. Equation
7、 No. 1 is then solved for the area of the filter. This calculated filter area is used in subsequent calculations of flow rates measured with the filter holder. Refer to the sample calculation and Table 1. This procedure is sued to calibrate the system for each new filter holder or whenever changes a
8、re made in the air pressure regulator, pressure gauge, or batch of filter paper (AC MS-4275). To compensate for possible variations in pressure gauges, a slight adjustment in air pressure (+/- 7 kPa) may be made to keep the average flow time of Ford Reference Oil No. 1 in the range of 5.5 to 6.5 sec
9、onds. The pressure must be held constant after this adjustment. Materials Required Dry Ice Compressed Air Regulated to 69 kPa. Automotive Oil Filter Paper 40 micrometre AC MS-4275 - (refer to Note 3). Deionized or Distilled Water 20 micromhos/cm at 25 C max conductivity (ASTM D 1125). Reference Oils
10、 Refer to Note 3. Note 3: Information on availability of reference oils (FR No. 1 and FR No. 2) and AC MS-4275 filter paper can be obtained from: Fuels and Lubricants Section Engine Product and Manufacturing Engineering Engine Division, EEE Bldg. 21500 Oakwood Blvd. Dearborn, Michigan 48121 Conditio
11、ning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD B
12、J 124-01 Page 3 of 8 Copyright 2001, Ford Global Technologies, Inc. Procedure 1. Tests on the engine oil(s) must be run in duplicate at 23 +/- 2 C along with at least one test with each of the Ford Reference Oils. . New oil flowrate is to be checked at 5, 10, 15, 20, and 25 mL. . “Environmentalized“
13、 oil flowrate is to be checked at 5, 10, 15, 20, and 25 mL. . A plot of the flowrates vs oil volume shall be prepared for each run. . Percent change in flowrate shall be determined each test. The results of the Ford Reference Oils (after environmentalization) must be similar (+/- 10 %) to those show
14、n below: mL FR No. 1 FR No. 2 Flowrate (s) (cm2) 0.95 0.1 or less Change in Flowrate (%) 20 95 2. “Cold“ Environment - mix 49.7 g of test oil, 0.3 g (0.3 mL with the microliter syringe) of deionized water and about 10 g of dry ice for 30 s at low speed in a Waring “mini-container.“ The top of the co
15、ntainer should be loosely covered to prevent oil spattering while allowing rapid vaporization of the dry ice. 3. “Hot“ Environment - transfer the sample to a 60 mL wide mouth glass bottle and place the uncapped bottle in an oven at 70 C for 30 minutes. Remove from the oven and allow to cool to 23 +/
16、- 2 C. 4. Store at 23 +/- 2 C for 48 +/- 2 h before determining the filterability. Filterability Note: Some form of safety shield should be utilized during this test. 5. The apparatus, a 25 mL buret, filter holder with automotive oil filter paper (AC MS-4275), and a source of 69 kPa air pressure, is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBJ12412001ENGINEOILFILTERABILITYTESTREPLACESFLTMBJ02401PDF

链接地址:http://www.mydoc123.com/p-747124.html