FORD FLTM AQ 101-1-2001 DETERMINATION OF PHOSPHATE COATING WEIGHTS - CHROMIC ACID METHOD (Replaces FLTM EU-AQ 001-01).pdf
《FORD FLTM AQ 101-1-2001 DETERMINATION OF PHOSPHATE COATING WEIGHTS - CHROMIC ACID METHOD (Replaces FLTM EU-AQ 001-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM AQ 101-1-2001 DETERMINATION OF PHOSPHATE COATING WEIGHTS - CHROMIC ACID METHOD (Replaces FLTM EU-AQ 001-01).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD AQ 101-01 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 2000 04 20 Editorial no technical change A. Cockman 1990 01 17 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF PHOSPHAT
2、E COATING WEIGHTS - CHROMIC ACID METHOD Application This procedure is used to determine the coating weight of iron, zinc or manganese phosphate used on iron or steel parts. Two methods are described in this procedure: Method A - employing test panels to check a phosphate coating system, and Method B
3、 - employing actual parts (primarily threaded fasteners) to determine the weight of phosphate on a submitted part. Materials and Solutions Required Chromic Acid Stripping Solution Dissolve 200 g of CrO3 in 500 ml of water and dilute to 1000 ml. Transfer the solution to a two-liter beaker and heat to
4、 93 C for stripping the coatings from the panels. Test Panels for Method A The test panels are 100 mm by 300 mm steel body stock (CRLC, Class A finish). Process two panels through a complete cycle of the phosphate coating system under test, including cleaning, phosphating, acid rinse (if required) a
5、nd drying. Test Parts for Method B Three or more actual production parts taken at random should be obtained from the lot, batch, etc., being evaluated. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50
6、+/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure Method A 1. Buff the 100 mm by 300 mm panels on the back or unexposed surface to remove any phosphate coating. Use a soft rag wheel for this purpose. FORD LABO
7、RATORY TEST METHOD AQ 101-01 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. 2. Cut a 100 mm by 100 mm section from each of the buffed panels for determination of coating weight. Deburr after cutting. 3. Remove any grease or foreign matter from the test specimens by washing with ether, ac
8、etone and ethanol. Pouring a mixture of the three solvents over the test specimens should remove any soil. 4. Blot the test specimens with a soft cloth and then dry in an oven at 100 +/- 2 C for five minutes. 5. Cool in a desiccator and weigh the test specimens to the nearest milligram. 6. Immerse t
9、he test specimen in the chromic acid stripping solution for approximately 90 seconds. 7. Rinse the test specimens in running water. Blot and then dry in an oven at 100 +/- 2 C. 8. Cool in a desiccator, reweigh and repeat Steps 6, 7 and 8 to constant weight. Calculations loss in wt. (mg) = mg of coat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAQ10112001DETERMINATIONOFPHOSPHATECOATINGWEIGHTSCHROMICACIDMETHODREPLACESFLTMEUAQ00101PDF

链接地址:http://www.mydoc123.com/p-746827.html