FORD ESF-M3L48-A-2003 CABLE CONDUIT NONMETALLIC-FLAME RETARDANT TO BE USED WITH FORD WSS-M99P1111-A 《阻燃非金属电缆管道 与标准FORD WSS-M99P1111-A一起使用 》.pdf
《FORD ESF-M3L48-A-2003 CABLE CONDUIT NONMETALLIC-FLAME RETARDANT TO BE USED WITH FORD WSS-M99P1111-A 《阻燃非金属电缆管道 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD ESF-M3L48-A-2003 CABLE CONDUIT NONMETALLIC-FLAME RETARDANT TO BE USED WITH FORD WSS-M99P1111-A 《阻燃非金属电缆管道 与标准FORD WSS-M99P1111-A一起使用 》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 06 30 Revised Para 3.0 inserted; Para 3.5 & 4 deleted 1978 11 07 Metricated, Renumbered and Retyped CF4H-RD567168-41 1963 07 17 Released F6-1082 Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 1 of 3 CA
2、BLE CONDUIT, NONMETALLIC - FLAME RETARDANT ESF-M3L48-A 1. SCOPE The material defined by this specification is a flexible nonmetallic conduit, composed of cotton warp yarns and kraft paper fillers woven in a tubular form and impregnated with a satisfactory asphaltic solution, coated with a black wax
3、and paraffin solution. 2. APPLICATION This specification was released originally for material used as a protective covering on battery cables. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements F
4、or Production Materials (WSS-M99P1111-A). 3.1 TYPICAL WEB CONSTRUCTION See Table I OF VARIOUS SIZES 3.2 TREATMENT The conduit shall be saturated inside and out with an asphaltic compound and must be free from beads or seams or any obstruction, which will interfere with the free passage of the wire.
5、Treatment must be completely dry. All shipments over 100 pieces should be shipped so that the pieces are placed and held in a vertical position during transit and storage, and must be sound when received. Light colored dusting powders are objectionable. 3.3 PERFORMANCE TESTS The finished conduit mus
6、t withstand a temperature of 102 +/- 3 C for 15 min without dripping. Shall not absorb more than 35% of its weight after soaking in water at 23 +/- 2 C for 24 h, then blown out with a mild air current. Conduits must be capable of being bent around designated mandrels, at temperatures specified, with
7、out collapsing. (See Table I, mandrel size) ENGINEERING MATERIAL SPECIFICATIONESF-M3L48-APrinted copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 3 3.4 FLAME TEST Shall not support combustion for longer than a 1 min period. Test Method: Apply five 15 s applications of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESFM3L48A2003CABLECONDUITNONMETALLICFLAMERETARDANTTOBEUSEDWITHFORDWSSM99P1111A 阻燃 非金属 电缆 管道 标准 FORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-746205.html