EN ISO 11731-2-2008 en Water quality - Detection and enumeration of Legionella - Part 2 Direct membrane filtration method for waters with low bacterial counts《水质 军团藻属的探测和计数 第2部分 含含.pdf
《EN ISO 11731-2-2008 en Water quality - Detection and enumeration of Legionella - Part 2 Direct membrane filtration method for waters with low bacterial counts《水质 军团藻属的探测和计数 第2部分 含含.pdf》由会员分享,可在线阅读,更多相关《EN ISO 11731-2-2008 en Water quality - Detection and enumeration of Legionella - Part 2 Direct membrane filtration method for waters with low bacterial counts《水质 军团藻属的探测和计数 第2部分 含含.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN ISO 11731-2:2008 BS 6068-4.18:2004 Water quality Detection and enumeration of Legionella Part 2: Direct membrane filtration method for waters with low bacterial counts ICS 07.100.20; 13.060.70 BS EN ISO 11731-2:2008 This British Standard was published under the authority of th
2、e Standards Policy and Strategy Committee on 20 July 2004 BSI 2008 ISBN 978 0 580 60246 7 National foreword This British Standard is the UK implementation of EN ISO 11731-2:2008. It is identical with ISO 11731-2:2004. It supersedes BS ISO 11731-2:2004 which is withdrawn. The UK participation in its
3、preparation was entrusted by Technical Committee EH/3, Water quality, to Subcommittee EH/3/4, Microbiological methods. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Additional information This British Standard is not suitable for cooling tower
4、waters. In addition, laboratories using this method should satisfy themselves that the method works as well in their laboratory for their samples as BS 6068-4.12:1998 (ISO 11731:1998). This publication does not purport to include all the necessary provisions of a contract. Users are responsible for
5、its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication Date Comments 31 July 2008 This corrigendum renumbers BS ISO 11731-2:2004 as BS EN ISO 11731-2:2008. Also, additional information added to nationa
6、l forewordEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM ENISO117312 March2008 ICS07.100.20 EnglishVersion WaterqualityDetectionandenumerationofLegionellaPart2: Directmembranefiltrationmethodforwaterswithlowbacterial counts(ISO117312:2004) QualitdeleauRechercheetdnombrementdes LegionellaPartie2:Mtho
7、deparfiltrationdirectesur membranepourleseauxfaibleteneurenbactries(ISO 117312:2004) WasserbeschaffenheitNachweisundZhlungvon LegionellenTeil2:DirektesMembranfiltrationsverfahren mitniedrigerBakterienzahl(ISO117312:2004) ThisEuropeanStandardwasapprovedbyCENon24February2008. CENmembersareboundtocompl
8、ywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCENManagementCentreortoanyCENmember. ThisEuropeanS
9、tandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCENManagementCentrehasthesamestatusas the officialversions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Bulgaria,C
10、yprus,CzechRepublic,Denmark,Estonia,Finland, France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,P ortugal, Romania,Slovakia,Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION
11、EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2008CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.ENISO117312:2008:EForeword The text of ISO 11731-2:2004 has been prepared by Technical Committee ISO/TC 147 “Water quality”
12、of the International Organization for Standardization (ISO) and has been taken over as EN ISO 11731-2:2008 by Technical Committee CEN/TC 230 “Water analysis” the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an
13、identical text or by endorsement, at the latest by September 2008, and conflicting national standards shall be withdrawn at the latest by September 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not
14、 be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia,
15、Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 11731-2:2004 has been approved by CEN as
16、 a EN ISO 11731-2:2008 without any modification. BS EN ISO 11731-2:2008 iii Contents Page 1 Scope 1 2 Normative references . 1 3 Terms and definitions. 1 4 Safety 2 5 Principle . 2 6 Culture media and reagents. 2 7 Apparatus 6 8 Sampling 7 9 Procedure 7 10 Expression of results 9 11 Test report . 9
17、Annex ZA (informative) A-deviations.10 BS EN ISO 11731-2:2008 blankI SO 4002 All irthgs ersedevr 1Water quality Detection and enumeration of Legionella Part 2: Direct membrane filtration method for waters with low bacterial counts WARNING Persons using this part of ISO 11731 should be familiar with
18、normal laboratory practice. This part of ISO 11731 does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions. 1 Sc
19、ope This part of ISO 11731 describes a monitoring method for the isolation and enumeration of Legionella organisms in water intended for human use (e.g. hot and cold water, water used for washing), for human consumption and for treated bathing waters (e.g. swimming pools). It is especially suitable
20、for waters expected to contain low numbers of Legionella. As the growth of Legionella may be inhibited by overgrowth of other bacterial colonies on the membrane, the method is only suitable for waters containing low bacterial counts. 2 Normative references The following referenced documents are indi
21、spensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696:1987, Water for analytical laboratory use Specification and test methods ISO 8199:
22、1) , Water quality General guidance on the enumeration of micro-organisms by culture ISO 11731:1998, Water quality Detection and enumeration of Legionella 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 Legionella genus of Gram-negative bacte
23、ria normally capable of growth in no less than 2 days on buffered charcoal yeast extract agar containing L-cysteine and iron(III), and forming colonies, often white, purple to blue or lime green in colour NOTE Some species fluoresce under long wavelength UV light. The colonies have a ground-glass ap
24、pearance when viewed with a low power stereomicroscope. Growth does not occur in the absence of L-cysteine with the exception of L. oakridgensis and L. spiritensis. L. oakridgensis and L. spiritensis require L-cysteine and iron for primary isolation but can grow weakly in the absence of added L-cyst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO1173122008ENWATERQUALITYDETECTIONANDENUMERATIONOFLEGIONELLAPART2DIRECTMEMBRANEFILTRATIONMETHODFORWATERSWITHLOWBACTERIALCOUNTS

链接地址:http://www.mydoc123.com/p-724612.html