EN 61580-2-1996 en Methods of Measurement for Waveguides Part 2 Level of Intermodulation Products《波导测量方法 第2部分 互调电平 IEC 1580-2 1996》.pdf
《EN 61580-2-1996 en Methods of Measurement for Waveguides Part 2 Level of Intermodulation Products《波导测量方法 第2部分 互调电平 IEC 1580-2 1996》.pdf》由会员分享,可在线阅读,更多相关《EN 61580-2-1996 en Methods of Measurement for Waveguides Part 2 Level of Intermodulation Products《波导测量方法 第2部分 互调电平 IEC 1580-2 1996》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN b3580-2-ENGL 1777 m lbZLIbb9 0587382 BRITISH STANDARD _I Methods of measurement for waveguides Part 2. Level of intermodulation products The European Standard EN 61580-2 : 1996 has the status of a British Standard II17 m BS EN 61580-2 : 1997 IEC 1580-2 11996 SI PERMISSION EXCEPT AS PER
2、MITTED BY COPYRIGHT LAW therefore, the measurement of these signals characterise the WUT in a sufficient way. However, the test Set-ups given in this procedure are also suitable for measuring intermodulation products of higher order. 3 Set-up Two different test Set-ups are described. Both of them al
3、low the measurement of inter- modulation signals of more than 100 dB below carrier level. The set-up on figure 1 may be assembled from standard microwave radio link hardware selected for this particular application. There are two critical components in this configuration which must be carefully chec
4、ked for lowest self-intermodulation generation: the summing device and the circulator used for the decoupling of the intermodulation signals. The set-up on figure 2 allows the combination of current laboratory signal generating devices with one power amplifier only. The self-intermodulation free mea
5、surement dynamic range depends only on the quality of the filter diplexer used for the decoupling of the intermodulation signals. NOTE - The results of measured intermodulation levels of WUT, with mora than one flange generating intermodulation products. can be falsified by super-position. To verify
6、 a reproducible measurement Set-up, knocking the flanges with a screwdriver could be helpful. Experience shows that devices containing magnetic materials (circulators, isolators, etc.) can be prominent sources for intermodulation signal generation. 3.1 Set-up 1 Two or more high power signal sources
7、or signal generators with power amplifiers are required to reach the specified sum power. The summing device may be a circulator, hybrid junction, coupler or filter network provided that the self-intermodulation generated is at least 10 dB below the level to be measured on the WUT. The WUT shall be
8、terminated by a load for the specified power if necessary. The receiving band-pass filter, tuned for the desired intermodulation signal is followed by a low-noise amplifier (if required) and a receiver. 3.2 Test equipment In order to reach level differences of 100 . 150 dB between the carrier leve)
9、and the intermodulation signals, high-performance test equipment is required. All components must be carefully chosen for lowest levels of self-intermodulation generation (see note 4 in 3.3). The Set-up illustrated in figure 1 consists of: signal generators, power output to produce the specified sum
10、 power: frequency stability to match the requirements of the measuring receiver; low-pass filters; isolators; power combiner (see note 1 in 3.3); circulator (see note 2 in 3.3); load; band-pass filter: low-noise amplifier; measuring receiver (see note 3 in 3.3); signal generator for level calibratio
11、n. 3.3 Set-up2 The set-up in figure 2 consists of two or more frequency stabilised signal generators combined with a power-combiner or hybrid. NOTES 1 Alternatively, circulator(s), directional coupler(s). hybrid junctions or fllter networks may be used. 2 The circulator may be replaced by a filter d
12、iplexer. 3 The measuring receiver may be replaced by a spectrum analyser. 4 The interface flanges to the WUT are best constructed as A-type (choke) flanges for minimum intermodulation. For the combined signal, only one power amplifier allowing for the sum power specified for the intermodulation test
13、 is necessary. The high-pass filter at the amplifier output suppresses all intermodulation signals (2Fp - Fs, etc.) below Fp and also the broadband noise, generated by the power amplifier. Furthermore, it acts as a diplexer system together with the receiving band filter. For this Set-up, the low-pad
14、band-pass combination must be designed and selected for a self-intermodulation level of at least 10 dB below the level to be measured on the WUT. STD-BSI SbL58O-2-ENGL 1777 1b24bb70587171 1F1-m Page 6 EN 61580-2 : 1996 The receiving band-pass filter, tuned for the lowest intermodulation signal as de
15、scribed, is followed by a low-noise amplifier (if required) and a receiver. As an alternative, high power generators or generators with individual power amplifiers can be combined to provide the necessary power level. Care must be taken that the high power levels do not produce excessive intermodula
16、tion products in the summing devices. 3.4 Test equipment In order to reach level differences of 100 . 150 dB between the carrier level(s) and the intermodulation signals, high-performance test equipment is required. All components must be carefully chosen for lowest levels of self-intermodulation (s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6158021996ENMETHODSOFMEASUREMENTFORWAVEGUIDESPART2LEVELOFINTERMODULATIONPRODUCTS 波导 测量方法 部分 电平 IEC158021996PDF

链接地址:http://www.mydoc123.com/p-720314.html