1、BRITISH STANDARD BS EN 61315:2006 Calibration of fibre-optic power meters The European Standard EN 61315:2006 has the status of a British Standard ICS 33.140; 33.180.10 BS EN 61315:2006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 6 March
2、2006 BSI 6 March 2006 ISBN 0 580 47924 2 National foreword This British Standard is the official English language version of EN 61315:2006. It is identical with IEC 61315:2005. It supersedes BS EN 61315:1997 which is withdrawn. The UK participation in its preparation was entrusted to Technical Commi
3、ttee GEL/86, Fibre optics, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in th
4、e BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible
5、for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK inter
6、ests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 42, an inside back cover and a back cover. The BSI copyright notice displayed in this doc
7、ument indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments EUROPEAN STANDARD EN 61315 NORME EUROPENNE EUROPISCHE NORM January 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europi
8、sches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61315:2006 E ICS 33.140;33.180.10 Supersedes EN 61315:1997English version C
9、alibration of fibre-optic power meters (IEC 61315:2005) Etalonnage de wattmtres pour dispositifs fibres optiques (CEI 61315:2005) Kalibrierung von Lichtwellenleiter- Leistungsmessern (IEC 61315:2005) This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to comply wi
10、th the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretar
11、iat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the
12、official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Sl
13、ovenia, Spain, Sweden, Switzerland and United Kingdom. 2 Foreword The text of document 86/239/FDIS, future edition 2 of IEC 61315, prepared by IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61315 on 2005-11-01. This European Standard superse
14、des EN 61315:1997. Changes from EN 61315:1997 consist of adapting the uncertainty calculations to the approach taken by the GUM, and adapting the terminology and graphical symbology to international standards VIM, IEC 61931 and IEC 61930. The importance of the nonlinearity calibration is emphasized
15、by giving more detail and is now in a separate clause. Requirements concerning organization and traceability have been taken out of this standard since they are general requirements concerning calibration laboratories and are given in EN ISO/IEC 17025. The goal to standardize the type of power meter
16、 specifications has been removed since it does not belong in a standard on calibration. Specifications should, however, still be based on calibrations made following this standard and EN 60359. The following dates were fixed: latest date by which the EN has to be implemented at national level by pub
17、lication of an identical national standard or by endorsement (dop) 2006-08-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-11-01 _ Endorsement notice The text of the International Standard IEC 61315:2005 was approved by CENELEC as a European Sta
18、ndard without any modification. _ EN 61315:2006 3 EN 61315:2006 CONTENTS INTRODUCTION 4 1 Scope 5 2 Normative references .5 3 Terms and definitions .6 4 Preparation for calibration 13 4.1 Organization13 4.2 Traceability .13 4.3 Advice for measurements and calibrations .14 4.4 Recommendations to cust
19、omers 15 5 Absolute power calibration15 5.1 Establishing the calibration conditions .16 5.2 Calibration procedure 17 5.3 Calibration uncertainty.18 5.4 Reporting the results .25 6 Measurement uncertainty of a calibrated power meter.25 6.1 Uncertainty at reference conditions25 6.2 Uncertainty at oper
20、ating conditions26 7 Nonlinearity calibration.33 7.1 Nonlinearity calibration based on superposition .34 7.2 Nonlinearity calibration based on comparison with a calibrated power meter 36 7.3 Nonlinearity calibration based on comparison with an attenuator37 7.4 Calibration of power meter for high pow
21、er measurement 37 Annex A (normative) Mathematical basis39 A.1 Type A evaluation of uncertainty39 A.2 Type B evaluation of uncertainty39 A.3 Determining the combined standard uncertainty.40 A.4 Reporting 41 Figure 1 Typical spectral responsivity of photoelectric detectors.11 Figure 2 Example of a tr
22、aceability chain.13 Figure 3 Measurement setup for sequential, fibre-based calibration16 Figure 4 Change of conditions and uncertainty.21 Figure 5 Determining and recording an extension uncertainty.27 Figure 6 Possible subdivision of the optical reference plane into 10 x 10 squares, for the measurem
23、ent of the spatial response.28 Figure 7 Wavelength dependence of response due to Fabry-Perot type interference.32 Figure 8 Measurement setup of polarization dependent response.32 Figure 9 Nonlinearity calibration based on superposition 34 Figure 10 Measurement setup for nonlinearity calibration by c
24、omparison36 Table 1 Typical calibration methods and correspondent power .15 Table 2 Nonlinearity.35EN 61315:2006 4 INTRODUCTION Fibre-optic power meters are designed to measure optical power from fibre-optic sources as accurately as possible. This capability depends largely on the quality of the cal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN613152006ENCALIBRATIONOFFIBREOPTICPOWERMETERS 光纤 功率 校准 IEC613152005PDF

链接地址:http://www.mydoc123.com/p-720076.html