EN 15254-5-2009 en Extended application of results from fire resistance tests - Nonloadbearing walls - Part 5 Metal sandwich panel construction《防火测试结果的扩展应用 非承重墙 第5部分 金属夹层板结构》.pdf
《EN 15254-5-2009 en Extended application of results from fire resistance tests - Nonloadbearing walls - Part 5 Metal sandwich panel construction《防火测试结果的扩展应用 非承重墙 第5部分 金属夹层板结构》.pdf》由会员分享,可在线阅读,更多相关《EN 15254-5-2009 en Extended application of results from fire resistance tests - Nonloadbearing walls - Part 5 Metal sandwich panel construction《防火测试结果的扩展应用 非承重墙 第5部分 金属夹层板结构》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 15254-5:2009Extended application of resultsfrom fire resistance tests Non-loadbearing wallsPart 5: Metal sandwich panel constructionBS EN 15254-5:2009 BRITISH STANDARDNatio
2、nal forewordThis British Standard is the UK implementation of EN 15254-5:2009.BSI, as a member of CEN, is obliged to publish EN 15254-5 as a British Standard. However, attention is drawn to the fact that during the development of this European Standard, the UK committee voted against its approval as
3、 a European Standard. The main reasons for this negative vote are as follows.1. Table 2 is unclear as a rule for the orientation parameter for panel joints, where joints could be used that might differ from those which are tested. The UK interpretation is that, as a gen-eral rule, the test result is
4、 only valid for the tested orientation. This rule also refers users to Annex B; however this Annex applies to span length and not orientation.2. Subclause 5.2.4.2 allows for an increase in binder content of mineral wool of 2 % for products with binder content of less than 10 %. The UK committee are
5、concerned that this could change the fire resistance properties and negatively affect test performance. 3. Subclause 5.3.1 and Annex B present a model for calculating an increase in span lengths. An ultimate limit of 12 m is intro-duced in Annex B. The UK committee are of the opinion that this is to
6、o high and point out that it has not been validated by testing.The UK committee advise users to be aware of these concerns when applying this standard, particularly in the context of a fire risk assessment of the application. The UK participation in its preparation was entrusted to Technical Committ
7、ee FSH/22/-/7, Fire resistance tests for partitions and walls.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.
8、BSI 2011ISBN 978 0 580 55406 3ICS 13.220.50; 91.060.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2011.Amendments issued since publicationDate Text
9、 affectedBS EN 15254-5:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15254-5 November 2009 ICS 13.220.50; 91.060.10 English Version Extended application of results from fire resistance tests - Non-loadbearing walls - Part 5: Metal sandwich panel construction Application tendue des rsultat
10、s dessais de rsistance au feu - Murs non porteurs - Partie 5 : Panneaux sandwiches mtalliques pour la construction Erweiterter Anwendungsbereich der Ergebnisse von Feuerwiderstandsprfungen - Nichttragende Wnde - Teil 5: Sandwichelemente in Metallbauweise This European Standard was approved by CEN on
11、 5 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may
12、 be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CE
13、N Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlan
14、ds, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in a
15、ny form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15254-5:2009: EBS EN 15254-5:2009EN 15254-5:2009 (E) 2 Contents Page Foreword . 31 Scope 42 Normative references . 43 Terms and definitions, symbols and abbreviations 43.1 Terms and definitions . 43.2 Symbols and abbre
16、viations . 54 Establishing the field of extended application 64.1 General . 64.2 Assumptions in the extended application 64.3 Assumed structural behaviour of a sandwich panel in fire 75 Rules for extended applications of the tested product . 75.1 General . 75.2 Variations in the materials of the pro
17、duct 95.2.1 General . 95.2.2 Variations in the metal sheets . 105.2.3 Variations in the adhesive 115.2.4 Variations in the core material . 115.3 Variations in the construction . 125.3.1 Variations in span length . 125.3.2 Variations in the panel thickness 135.3.3 Variations in the joint construction
18、 . 135.3.4 Variations in the boundary conditions and fixing system 135.3.5 Length and height of wall construction 135.4 Interaction between the factor influences 135.5 Support structure 145.6 Heating conditions 146 Small scale tests and calculation methods 146.1 Small scale tests . 146.2 Calculation
19、 methods . 146.2.1 General . 146.2.2 Calculation of strength properties 146.3 Additional measurements to be carried out in the reference test . 157 Report of the extended application analysis . 15Annex A (informative) Typical behaviour of a metal faced sandwich panel wall when exposed to fire . 16An
20、nex B (normative) Evaluation of extension of span length . 17Bibliography . 20BS EN 15254-5:2009EN 15254-5:2009 (E) 3 Foreword This document (EN 15254-5:2009) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standa
21、rd shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this docum
22、ent may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirement
23、s of EU Directive(s). This standard is currently composed of the following parts: EN 15254-2, Extended application of results from fire resistance tests Non-loadbearing walls Part 2: Masonry and Gypsum Blocks EN 15254-4, Extended application of results from fire resistance tests Non-loadbearing wall
24、s Part 4: Glazed constructions EN 15254-5, Extended application of results from fire resistance tests Non-loadbearing walls Part 5: Metal sandwich panel construction prEN 15254-7, Extended application of results from fire resistance tests Non-loadbearing walls Part 7: Non-load bearing sandwich panel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1525452009ENEXTENDEDAPPLICATIONOFRESULTSFROMFIRERESISTANCETESTSNONLOADBEARINGWALLSPART5METALSANDWICHPANELCONSTRUCTION

链接地址:http://www.mydoc123.com/p-714898.html