EN 285-2006 6250 Sterilization - Steam sterilizers - Large sterilizers (Incorporates Amendment A2 2009)《消毒 蒸气消毒 大型消毒设备 包含修改件A2-2009》.pdf
《EN 285-2006 6250 Sterilization - Steam sterilizers - Large sterilizers (Incorporates Amendment A2 2009)《消毒 蒸气消毒 大型消毒设备 包含修改件A2-2009》.pdf》由会员分享,可在线阅读,更多相关《EN 285-2006 6250 Sterilization - Steam sterilizers - Large sterilizers (Incorporates Amendment A2 2009)《消毒 蒸气消毒 大型消毒设备 包含修改件A2-2009》.pdf(90页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 285:2006 +A2:2009Sterilization Steam sterilizers Large sterilizersICS 11.080.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g5
2、8Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 285:2006+A2:2009. It supersedes BS EN 285:2006+A1:2008 whic
3、h is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was ent
4、rusted to Technical Committee LBI/35, Sterilizers, autoclaves and disinfectors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its corr
5、ect application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 285:2006+A2:2009This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2006 BSI 2010Amendments/corrigenda issued since publicationDate Com
6、ments 30 June 2008 Implementation of CEN amendment A1:200831 January 2010 Implementation of CEN amendment A2:2009ISBN 978 0 580 65145 8Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS
7、-,-,-EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 285:2006+A2 May 2009 ICS 11.080.10 Supersedes EN 285:2006+A1:2008English Version Sterilization - Steam sterilizers - Large sterilizers Strilisation - Strilisateurs la vapeur deau - Grands strilisateurs Sterilisation - Dampf-Sterilisatoren - G
8、ro-Sterilisatoren This European Standard was approved by CEN on 27 April 2006 and includes Amendment 1 approved by CEN on 4 February 2008 and Amendment 2 approved by CEN on 5 April 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for givi
9、ng this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official ver
10、sions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgiu
11、m, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR S
12、TANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 285:2006+A2:2009: ECopyright European Committee
13、for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 285:2006+A2:2009 (E) 2 Contents Page Foreword 41 Scope 52 Normative references 53 Terms and definitions . 64 Mechanical components . 115 Process components
14、146 Instrumentation, indicating and recording devices . 157 Control systems . 228 Performance requirements . 239 Sound power 2610 Rate of pressure change . 2611 Safety 2712 Marking . 2713 Service and local environment . 2714 Testing 2915 !Hollow load test“ . 3116 Thermometric tests 3217 Bowie and Di
15、ck test . 3618 Air leakage test 3719 Air detector tests . 3820 Load dryness tests 4121 Sound power test . 4422 Steam quality tests 4523 Dynamic sterilizer chamber pressure test 5524 Test apparatus, equipment and material . 5625 Documentation to be supplied by the manufacturer . 6326 Information to b
16、e supplied by the manufacturer 64Annex A (informative) Environmental aspects . 67Annex B (informative) Steam supply; suggested maximum values of contaminants in feed water and condensate . 72Annex C (informative) Recommended materials 73Annex D (informative) Temperature and time tolerances during th
17、e small load thermometric test. 76Annex E (informative) Guidance for installation and operational qualification tests to be included in the instructions for use supplied with a sterilizer 77Annex F (informative) Criteria for identifying sterilizers as the same type . 79Annex ZA (informative) Relatio
18、nship between this European Standard and the Essential Requirements of EU Directive 93/42/EEC on medical devices . 80BS EN 285:2006+A2:2009Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from
19、 IHS-,-,-EN 285:2006+A2:2009 (E) 3 Bibliography 85BS EN 285:2006+A2:2009Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 285:2006+A2:2009 (E) 4 Foreword This document (EN 285:2
20、006+A2:2009) has been prepared by Technical Committee CEN/TC 102 “Sterilizers for medical purposes”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Novemb
21、er 2009 and conflicting national standards shall be withdrawn at the latest by March 2010. This document includes Amendment 1, approved by CEN on 2008-02-04 and Amendment 2, approved by CEN on 2009-04-05. This document supersedes #EN 285:2006+A1:2008$. The start and finish of text introduced or alte
22、red by amendment is indicated in the text by tags ! “ and # $. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informati
23、ve Annex ZA, which is an integral part of this document. This document does not specify requirements for the validation and routine control of sterilization by moist heat. A European Standard specifying requirements for the validation and routine control of sterilization by moist heat was prepared b
24、y CEN/TC 204 “Sterilization of medical devices“, see EN 554 (currently under revision, see prEN ISO 17665). The performance requirements specified in this document are not intended for the process to be effective in inactivating the causative agents of spongiform encephalopathies such as scrapie, bo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN28520066250STERILIZATIONSTEAMSTERILIZERSLARGESTERILIZERSINCORPORATESAMENDMENTA22009 消毒 蒸气 大型 设备 包含

链接地址:http://www.mydoc123.com/p-710386.html