ECA TEP 181-1980 Measurement of X-Radiation from Power Tubes Recommended Practice for《功率管中X射线泄露测量的推荐实践》.pdf
《ECA TEP 181-1980 Measurement of X-Radiation from Power Tubes Recommended Practice for《功率管中X射线泄露测量的推荐实践》.pdf》由会员分享,可在线阅读,更多相关《ECA TEP 181-1980 Measurement of X-Radiation from Power Tubes Recommended Practice for《功率管中X射线泄露测量的推荐实践》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、EIA TEP181 BO m 3234600 0008511 T m - FROM POWER TUBES NOVEMBER 1980 RECOMMENDED PRACTICE FOR MEASUREMENT OF X-RADIATION FORMULATED BY EIA TUBE ENGINEERING PANEL ADVISORY COUNCIL (TEPAC) TEPAC PUBLICATION No. 181 (Revision of TEPAC Publication No. 81) EIA TEP181 80 = 3234b00 0008532 I m Published by
2、 ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W., Washington, D.C. 20006 PRICE: $4.00 - a- * - EIA TEP181 80 m 3234b00 0008513 3 m RECOMMENDED PRACTICE FOR MEASUREMENT OF X-RADIATION FROM POWER TUBES TEPAC PUBLICATION NO. 181 This publication was prepared by the JT-32
3、Committee on Electron Tube Safety and approved by the Tube Engineering Panel Advisory Council (TEPAC) 1, Purpose and Scope 1.1 Purpose - To obtain the X-radiation characteristics of power tubes in order to determine the levels emitted by the tubes when they are operated with integral tube shielding
4、in place, but without external shielding. JEDEC Publication No. 81 .) (This pub1 ication replaces and supersedes 1.2 Scope - This test method applies to the measurement of incidental X-radiation emitted from power tubes. CAUTION: SAFETY CONSIDERATIONS Measuring instruments should be properly grounde
5、d. Caution should be taken to auoid shock hazard, par- ticuZmly in the vicinity of the anode connection and the voZtage metering system. Safety gksses should be worn at all times during the measurement procedure. X-ray film badges should be worn in accordance with established plant safety practices
6、for monitoring radiation dosage. 2. . Apparatus 2.1 Search Instruments - For Initial Survey a, Rapid response instruments used for locating the position of maximum i ntensi ty . Example: Texas Nuclear Model 2652 GM Portable Survey Meter b. X-ray Film. For use in initial surveys to determine the X-ra
7、diation pattern and for locating positions of maximum EIA TEP181 80 m 3234600 00085L4 5 = intensity. Examples of X-ray films are as. QOEIS; 1. No Screen Medical X-Ray Film, double coated duplitized 2. Industrial X-Ray Film, double coated Estar Base 2.2 Measuring Instruments - for making defini tive
8、measurements. Measuring instruments shall be calibrated in the range of energies and exposure rates comparable to that of the X-radiation emitted by the tube to be tested. The instruments shall read in units of exposure rate, i.e., R/h, mR/h, and they shall be shielded against RF interference. a. b.
9、 c. Examples are as follows: Victoreen Model 440 RF/C RF Shielded Low-Energy Survey Meter Victoreen Model 440 RF Radiation Exposure Rate Measuring System Victoreen Model 666 F1 uoroscopic Survey Meter complete with background probe Model 666-25 modified with Mylar window and diagnostic probe d, Vict
10、oreen Model 471 RF Survey Meter (RF Shielded) e. Texas Nuclear Model 2652 GM Portable Survey Meter f. Condenser Ionization Chambers: Victoreen Model 208A Victoreen Model 239A Victoreen Model 687C Minometer Charger-Reader g. Harshaw Chemical TLD1 O0 Thermal Luminescent Dosimeter and Reader 2.3 Test E
11、quipment - To provide stable electronic conditions for operation of the power tube under test and to measure voltage and current. 2.3.1 High-Voltage Meter - A meter for measurement of the high-voltage with an accuracy of at least 0.5% for direct current, 1% for alternating current and 2% for pulse v
12、ol tage measurements (*Note). Calibrate using a high-voltage divider with suitable accuracy and *Note: If the recommended accuracy of the measurement system cannot be achieved then the inaccuracy shall be accounted for by reducing the recorded vol tage reading by the maximum possible measurement dev
13、iation. 2.3.2 Current Meter A meter for measurement of current with less than 2% error. -2- P 4 O - EIA TEP381 80 E 3234600 O008535 7 E i- - 2.3.3 2.3.4 Waveform Oscilloscope - A device to measure pulse duration. RF Counter - A device to measure pulse repetition rate. 3. Cal i bration X-radiation me
14、asuring instruments shall be calibrated regularly by exposure to a spatially uniform X-ray field having an exposure rate and energy representative of the fields to be measured. The calibration shall be traceable to the National Bureau of Standards. The stability of calibration of X-radiation measuri
15、ng instruments should be checked prior to use. An internal radioactive check source or one supplied by the instrument manufacturer is a con- venient means of checking the stability of the calibration. 4. Measurement Conditions 4.1 General - Measurement of X-radiation arising from the operation of po
16、wer tubes is general ly separable into two categories. a. Initial or general surveys b. Measurements on power tubes having known X-radiation patterns. In making surveys, especially initial surveys, it is important that no assumptions be made regarding the nature of the field pattern to be expected.
17、When the X-radiation pattern is known, the power tube being meas- ured shall be positioned relative to the measurement equipment so that measurements are made at the point where maximum X-radiation is observed. beginning measurements so that measurement equipment and the tube being measured are oper
18、ating at stable specified conditions. Shunt Regulators - The tube being measured shallbe operated at the maximum rated dc anode (not supply) voltage and current, which shall not vary (including ripple) or drift more than, rr0.5% in voltage and +2% in current the entire measurement period. If the com
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECATEP1811980MEASUREMENTOFXRADIATIONFROMPOWERTUBESRECOMMENDEDPRACTICEFOR 功率管 射线 泄露 测量 推荐 实践 PDF

链接地址:http://www.mydoc123.com/p-704570.html