1、EIA STANDARD RECOMMENDED PRACTICE FOR PREPARATION OF BASING OR TERMINAL DIAGRAMS RSw206.C (Revision of RS-206-B) JUNE 1980 Engineerng Department ELECTRONIC INDUSTRIES ASSOCIATION NOTICE EIA Engineering Standards are designed to serve the public interest through eliminating misunderstandings between
2、manufacturers and purchasers, f aci- litating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such standards shall not in any respect preclude any member or non-member o
3、f EIA from manufacturing or selling products not conforming to such standards, nor shall the existence of such standards preclude their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended standards are adopted by IA ,w
4、ithout regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the recommended standards. This EIA Recommended Standard is c
5、onsidered to have international stan- dardization implications, but the IEC (or ISO) activity has not progressed to the point where a valid comparison between the EIA Recommended Standard and the IEC (or ISO) Recommendation can be made. . ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001
6、 Eye Street, N.W., Washington, D.C. 20006 PRICE: $4.00 . . *. RECOMMENDED PRACTICE FOR PREPARATION OF BASING OR TERMINAL DIAGRAMS TABLE OF CONTENTS Paragraph 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13 Purpose General Graphic and Scope Symbols Terminal or Base-Pin Symbols Base-Pin Numbering Diagram De
7、signation Rules for Preparation of Diagrams-General Rules Applying to Multielectrode Types Rules Applying to Subminiature Types Rules Applying to Phototubes and Camera Tubes Rules Applying to Gas-Filled Tubes Rules Applying to Electrical Components Illustration of Application of Rules Page 1 1 1 2 2
8、 3 3 4 5 5 5 5 5 o EIA 206-C 80 3234600 0062944 3 RS-206-C Page 1 RECOMMENDED PRACTICE FOR PREPARATION OF BASING OR TERMINAL DIAGRAMS (From EIA Standards Proposal No. 1278, formulated under the cognizance of TEPAC Committee JT-6 on TV Picture Tubes.) 1. PURPOSE AND SCOPE It is the purpose of this St
9、andard to establish the basic rules, which shall be used as a guide in the preparation of basing and terminal diagrams for electron tubes and associated sealed devices. It is not intended to be applied to schematic or wiring diagrams although the depiction of the internal connections of the devices
10、may be applicable to such usage if desired. The rules herein promulgated have been specifically planned to cover low-power high- vacuum, gas and cathode ray tubes, klystrons, and photo-tubes. These rules do not cover other microwave, high-power vacuum, gas, storage, or x-ray tubes, as terminal infor
11、mation for those devices ordinarily is contained in the outline drawing. 2. GENERAL Basing or terminal diagrams shall indicate the essential electrical connections for electron tubes and associated sealed devices. The basing or terminal diagram shall consist of a tube graphic symbol, terminal or bas
12、e-pin symbols and base-pin numbers, and a diagram designation. These symbols shall be used to indicate the functional structure of a tube rather than its physical structure. No lettering shall be a portion of the diagram other than the diagram designation, the terminal or base-pin symbols, and requi
13、site notes as herein defined. 3. GRAPHIC SYMBOLS Graphic symbols as standardized by the American National Standards Institute (ANSI) in the latest issue of their standard ANSI/IEEE Std. 315-1975 (Y32.2) “Graphic Symbols for Electrical arid Eletronic Diagrams,“ shall be used in the preparation of TEP
14、AC (formerly JEDEC) basing and terminal diagrams. In the absence of suitable symbols as standardized by ANSI, symbols standardized by the Institute of Electrical and Electronic Engineers (IEEE), or symbols established by TEPAC (formerly JEDEC) may be used. . - EIA 20b-C 80 3234600 0062945 5 H RS-206
15、-C Page 2 4. TERMINAL OR BASE-PIN SYMBOLS 4.1 The following symbols shall be used with the, indicated significance on basing or terminal diagrams: A11 base pins present shall be labeled: IC- No external connection shall be made to any base pin marked fflCft. NOTE: Such a pin may have an internal con
16、nection to a tube element, or may be reserved for such connection as an option of the tube manufacturer, or, for other reasons, may cause trouble if .connected to any portion af an external circuit, IS- Any internal shield or other .element if not graphicaIy depicted which may require the establishm
17、ent of a definite potential to secure satisfactory operation. If internal shiefdng is graphieally depicted the designation “ICf1 shall not be used. An external connection may be made to any terminal designated lfLCtl only under the li ted conditions appearing on the data sheet. LC- NC- NOTE: Omitted
18、 base pins and pins marked “NCf are considered equivalent in the assignment of basing designationc- Pin present, but not internally connected. S- Any connection of an external shield integral with a tube. “External Shields“ are here considered to include the shell of a metal sleeve of a GT-tube base
19、, a lock-in base shell and an external conductive coating or casing. NOTE: The letter symbol iiS1i identifies. an external electronic shield connected to a. distinctive terminal which may or may nat require grounding according to circuit requirements. Where an external con- ductive coating serves as
20、 one side of a capacitor (as in cathode ray tubes) and is not designed to function as an electrostatic shield, the letter IrSt should not appear. S/NC-Metal envelope shell or no internal connection (not recommended for new types), NOTE: This letter combination, has been used on terminal dlagFarns wh
21、ich cover the case where a single diagram is used to give terminal connection information for similar glass and metal tubes. 5, BASE-PIN NUMBERING Base pins on basing or terminal diagrams shall be numbered in accordance with the latest issue of EL4 RS-202, shall be the highest pin number present in
22、the hase. The basing designation number EIA 20b-C 80 3234600 00b294b 7 a RS-206-C Page 3 6. DIAGRAM DESIGNATION A diagram designation may be assigned by the EIA Engineering Department when a type designation is assigned to the device. Previsouly assigned EIA basing designations not in conflict with
23、this system shall be retained as TEPAC designation numbers. Any obsolete or voided previously assigned EIA basing designation shall not be reassigned for TEPAC. Diagrams that differ only in supplemental internal connections (for example, internal shields) to pins already used shall be assigned the s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA206C1980RECOMMENDEDPRACTICEFORPREPARATIONOFBASINGORTERMINALDIAGRAMS 基础 终端 图表 准备 推荐 实践 PDF

链接地址:http://www.mydoc123.com/p-703951.html