1、e a A-A-54795 = 9999974 OLZLL7b 383 A-A-54795 11 January 1993 COMMERCIAL ITEM DESCRIPTION WATER TESTING KIT, BACTERIOLWICAL The General Services Administration has authorized the use of this Commercial Item Description as a replacement for Military Specification MIL-W-36258D which is cancelled. This
2、 Commercial Item Description covers a bacteriological water analysis kit, suitable for determining the potability of drinking water Salient characteristics: General. analysis kit using the membrane filter technique for determining total coliform in water under field conditions. The water analysis ki
3、t shall include a sanikarians kit, and an incubator that is electrically operated and includes multi-voltage selection. The sanitarians kit shall be designed to vacuum filter water samples through microporous filters. The incubator shall be operable from multi-voltage supply lines that include 12 an
4、d 24 volts DC, and 115 and 230 volts, 50/60 Hz AC. ambient temperatures ranging form -30F to 95OF. The incubator shall have the capacity to simultaneously accommodate 24 test samples that are held in 12 x 50 mm commercial size plastic Petri culture dishes that include media absorbent pads. Shall be
5、a self-contained bacteriological water The incubator shall be operable in Desian and construction. water analysis kit shall conform to Figures 1 and 2. The design and construction of the The complete water analysis kit shall be enclosed in a fiberglass-reinforced plastic carrying case (container) of
6、 such size and weight as to permit hand carrying by one man. The kit shall be provided with an incubator with operating controls, an incubator rack, a filter holder assembly with supporting base, a funnel assembly, a filter support assembly, a vacuum filter flask, repair parts and tools. AMSC N/A FS
7、C 6665 DISTRIBUTION STATEMENT A. distribution is unlimited. Approved for public release; Licensed by Information Handling ServicesA-A-54795 I 9999974 0121177 21T I A-A-54 7 9 5 Q case. The carrying case shall have maximum overall dimensions (without handle) of 15 inches long by 10 inches wide by 10
8、inches high. All corners and edges shall be round. throughout, and shall be capable of withstanding rough handling under field conditions. carrying handle shall be securely mounted on top of the cover . The carrying case shall be provided withaa dufficient number of pull/down corrosion-resisting met
9、al clamps of suitable size and tension to afford a rainproof and slashproof closure. The carrying case shall be so designed that the cover may be opened to a maximum position of 90 without the front end of the case lifting from the surface. A plastic holding device (insert) shall be mounted on the i
10、nside of the cover to hold the following components securely in place: Case shall be moisture and mold-resistant A plastic, collapsible A Sanitarians syringe for cutout wAn. A 4 ounce polyethylene screw cap bottle for cutout *BV1. A graduated sampling cup for cutout *lCn. A package of Endo broth for
11、 cutout IID1*. An 8 ounce polypropylene bottle with phenolformaldehyde screw cap for cutout *%“. As indicated in Figure 1, a pressure-sensitive plate shall be securely mounted on the outside of the carrying case at a position alongside the receptacle. permanently and legibly marked in red with the f
12、ollowing or a similar legend: The plate shall be nCATION: Set voltage selector switch prior to plugging in power cord.w 2 Licensed by Information Handling ServicesI A-A-54795 W 9999974 OL2LL78 L5b W A-A-54 7 9 5 ontrols, The incubator controls shall be Ca able O Incubator c g of maintaining an incub
13、ation within the incubator cavity in ambient temperatures varying from -30F to 95OF. A voltage selector switch shall allow the incubator to operate from 12 and 24 volt DC supply lines, and from 115 and 230 volt 50/60 Hz AC supply lines. As indicated in Figure 1, a control panel shall be mounted in t
14、he carrying case to hold the voltage selector switch, a temperature control dial, a pilot light, and a fuse holder. A male ottwist-lockgo type receptacle shall be mounted on the line cord for the voltage supply. gasket-mounted and recessed, and shall be supplied with a captive cover for protective c
15、overing when not in use. A bellows type thermostat shall be included for the incubator temperature control. The bulb of the thermostat shall include a protective metal shield and shallbe located in the bottom of the incubator cavity. The front and rear of the control panel shall include recesses to
16、house the power line cord and container for holding accessories and repair parts. temperature of 35Oc +. 0.5 c I outside of the carrying case, to accommodate an external The receptacle shall be Incubator rack. conforming to Figure 2 shall be provided for holding Petri culture dishes intended for sim
17、ultaneous incubation. The incubator rack shall have the overall capacity to accommodate 24 12 x 50 mm commercial size Petri culture dishes. The cross wire construction shall form wells to accommodate not less than 48 13 x 100 mm size test tubes in an upright position with the bottom shelf as a suppo
18、rt for the test tube bottoms. The frame, as a minimum dimension, shall be formed from 0.134 inch diameter (No. 10 Birmingham (B.W.) gauge) wire. The cross wires, as a minimum dimension, shall be formed from 0.083 inch diameter (No. 14 B.W. gauge) wire. The wires shall be securely welded or brazed in
19、 position. A square corrosion-resisting wire rack 3 Licensed by Information Handling ServicesA-A-54795 m 9999974 OL2LL79 o92 m A-A- 5 4 7 9 5 Sanitar ianls kit . A sanitarians kit shall be supplied, and shall consist of a metal syringe with a twoLway valve, and a sampling cup. The syringe and sampli
20、ng cup shall conform to Figure 2 and shall be dimensioned to fit into cutouts IrABr and respectively of the carrying case cover insert of Figure 1. The syringe with plunger in the closed position shall be 7-1/2 inches long and shall be fabricated from chrome-plated brass or corrosion-resisting steel
21、. barrel of the syringe shall include legible instructions for using the syringe. A 7-1/2 inch long fluorelastomer tube shall be attached to the inlet of the syringe by means of a luer adapter type termination. The other end of the fluorelastomer shall terminate with a nylon luer-tapered adapter. Th
22、e sampling cup shall be fabricated from corrosion-resisting steel that is .O007 to ,017 inch thick, and shall include graduations indicated in Figure 2. The external surface of the sampling cup shall have a No. 7 commercial mirror finish, The inside surface shall have a satin finish. The sampling cu
23、p shall be used to collect a water test sample, and shall have a capacity of 250 ml. The Filter holder sumort a ssemblv. A filter holder support assembly shall be supplied to vacuum filter the water sample through an inserted microporous disc filter: The attachment of the valved syringe (from the sa
24、nitarians kit) shall provide the vacuum pump action, The filter holder support assembly shall consist of the following: A funnel assembly with a locking ring (see Figure 1. A filter holder assembly with a support base and a removable screen (see Figure i). A beaker type vacuum filter flask (see Figu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA547951993WATERTESTINGKITBACTERIOLOGICAL 细菌学 测试 工具 PDF

链接地址:http://www.mydoc123.com/p-701777.html