DLA SMD-5962-13203 REV A-2013 MICROCIRCUIT HYBRID VOLTAGE REGULATOR ULTRA LOW DROPOUT POSITIVE ADJUSTABLE.pdf
《DLA SMD-5962-13203 REV A-2013 MICROCIRCUIT HYBRID VOLTAGE REGULATOR ULTRA LOW DROPOUT POSITIVE ADJUSTABLE.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-13203 REV A-2013 MICROCIRCUIT HYBRID VOLTAGE REGULATOR ULTRA LOW DROPOUT POSITIVE ADJUSTABLE.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Paragraph 1.4; added Vcontrol range(Voltages are relative to VOUT) +2 V to +36 V. Figure 2; corrected the terminal symbol names. Figure 3; corrected the terminal symbol names and locations. -sld 13-03-06 Charles F. Saffle REV SHEET REV A A SHEET
2、15 16 REV STATUS REV A A A A A A A A A A A A A A OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Greg Cecil THIS DRAWING IS AVAILABLE FOR
3、USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY Charles F. Saffle MICROCIRCUIT, HYBRID, VOLTAGE REGULATOR ULTRA LOW DROPOUT, POSITIVE, ADJUSTABLE DRAWING APPROVAL DATE 13-02-13 AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 67268 5962-13203 SHEET 1 OF 16 DSCC FORM 2233 APR 9
4、7 5962-E285-13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13203 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents f
5、ive product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN.
6、 The PIN shall be as shown in the following example: 5962 R 13203 01 K X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA
7、) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit fun
8、ction 01 8667, 8668 Voltage regulator, positive , low dropout, adjustable 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as
9、 qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This lev
10、el is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming
11、flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the
12、device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may
13、have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13203 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). Th
14、e case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style U See figure 1 8 Thru-hole Z See figure 1 8 Surface Mount 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Inpu
15、t voltage range, Vcontrol (Voltages are relative to VOUT) +40 V dc, -0.3 V dc Output short circuit duration . Indefinite Input-Output differential voltage . 26 V dc Output voltage . 36 V dc Operating junction temperature range . -55C to +150C Thermal Resistance, Junction temperature (JC) 7C/W Lead t
16、emperature (soldering, 10 seconds) +300C Storage temperature range -65C to +150C 1.4 Recommended operating conditions. Input voltage range (Voltages are relative to VOUT) . +1.0 V to +36 V dc Vcontrol range(Voltages are relative to VOUT) +2 V to +36 V Output voltage range 0 V to +36 V dc Input-Outpu
17、t differential voltage range .5 V to 26 V dc Case operating temperature range (TC) -55C to +125C 1.5 Radiation features. 2/ Maximum total dose available (Dose rate = 50 - 300 rad(Si)/s) . 100 krad(Si) 3/ Enhanced Low Dose Rate Sensitvity (ELDRS): (dose rate 10 mrad(Si)/s) 50 krad(Si) 4/ 2. APPLICABL
18、E DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT
19、OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. _ 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Bipolar device types may d
20、egrade from displacement damage from radiation which could affect RHA levels. These device types have not been characterized for displacement damage. 3/ The active elements that make up these devices on this drawing have been tested for Total Ionizing Dose (TID) in accordance with MIL-STD-883 test m
21、ethod 1019 condition A. RHA testing of the active elements covered on this SMD are tested in alternate package (TO3), not the packages as specified in paragraph 1.2.4. 4/ The active elments that make up this device has been tested to RHA designator level “R“ (100 krad(Si) of Method 1019, condition A
22、 of MIL-STD-883 and low dose rate tested to the requirements of Method 1019, condition D and paragraph 3.13.1 of MIL-STD-883 to 50 krad(Si) at +25C. No ELDRS effect was observed. The elements will be re-tested after design or process changes that can affect RHA response of these elements. RHA testin
23、g of the active elements covered on this SMD were done in alternate package (TO3), not the packages as specified in paragraph 1.2.4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13203 DLA LAND AND MARITIME
24、 COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596213203REVA2013MICROCIRCUITHYBRIDVOLTAGEREGULATORULTRALOWDROPOUTPOSITIVEADJUSTABLEPDF

链接地址:http://www.mydoc123.com/p-698524.html