DLA MIL-PRF-6106 26 G-2012 RELAYS ELECTROMAGNETIC 50 AMPERES SPST NO WITH 5 AMPERE SPDT AUXILIARY HERMETICALLY SEALED.pdf
《DLA MIL-PRF-6106 26 G-2012 RELAYS ELECTROMAGNETIC 50 AMPERES SPST NO WITH 5 AMPERE SPDT AUXILIARY HERMETICALLY SEALED.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-6106 26 G-2012 RELAYS ELECTROMAGNETIC 50 AMPERES SPST NO WITH 5 AMPERE SPDT AUXILIARY HERMETICALLY SEALED.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5945 MIL-PRF-6106/26G 18 September 2012 SUPERSEDING MIL-PRF-6106/26F 02 December 2011 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 50 AMPERES SPST, NO, WITH 5 AMPERE SPDT AUXILIARY HERMETICALLY SEALED This specification is approved for use by all Departments and Agencies of
2、the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification sheet and MIL-PRF-6106. FIGURE 1. Relay, outline drawing.INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/
3、26G 2 Inches mm Inches mm .005 0.13 .375 9.52 .010 0.25 .38 9.7.06 1.5 .437 11.10 .100 2.54 .44 11.2.11 2.8 1.91 48.5 .171 4.34 2.000 50.80.203 5.16 2.44 62.0 .31 7.9 2.50 63.5NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specif
4、ied, tolerances are .010 (0.25mm) for three place decimals and .03 (0.8 mm) for two place decimals. 4. Terminal numbers need not appear on the relay header providing there is affixed to the relay a suitable legible circuit diagram that identifies each terminal location specified. 5. Suppression leve
5、l - the maximum induced transient voltage (back EMF) shall be 50 volts, referenced to zero volts. 6. Terminal studs shall be rated at 171C. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/26G
6、 3 TABLE I. Rated contact load (amperes per pole) (case grounded). Type of load Life oper-ating cycles X 10328 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase Main Aux Main Aux Main Aux NO NC NO NC 400 50/60 400 50/60 400 50/60 400 50/60 Resistive 50 50 50 5 5 65 - 5 - - - - - Inductive 50 - - 3 3 65 -
7、 3 - - - - -Inductive 20 50 50 - - - - - - - - - - Motor - - - - - - - - - - - - - Lamp - - - - - - - - - - - - - Transfer, load - - - - - - - - - - - - - Mechanical life Reduced current - - - - - - - - - - - - - Intermediate current APPLICABLE PER SPECIFICATION REQUIREMENTS: COIL DATA: Nominal oper
8、ating voltage: 28 V dc. Maximum operating voltage: 29 V dc. Pickup voltage: 15 V dc, maximum, at 25C. Dropout voltage: 1.5 at 25C. Hold voltage: 7 V dc at 25C. Duty: continuous. Coil current: 0.280 ampere, maximum, at 28 V dc, 25C. OPERATIONAL DATA: Operate time: 35 milliseconds maximum with nominal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF610626G2012RELAYSELECTROMAGNETIC50AMPERESSPSTNOWITH5AMPERESPDTAUXILIARYHERMETICALLYSEALEDPDF

链接地址:http://www.mydoc123.com/p-692979.html