1、,MIL-B-37275A 65 W 777770b 0265773 O m MILITARY SPECIF BATH, WATER, DENTAL IMPRESSION MA MI L- B-37295A 17 August 1978 SUPERSEDING MIL-B-37295 15 August 1975 CATION ERIAL, LOW TEMPERATURE This specification is approved for use by al and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This
2、 specification covers a low temperature, e thermostatically control led water bath sui table for tempering 2. APPLICABLE DOCUMENTS Departments ectrically hea dental materia 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bid or request for proposal f
3、orm a part of this specifi- cation to the extent specified herein. SPEC IF I CAT IONS FEDERAL PPP-B-636 - Boxes , Shi pping , Fi berboard, MILITARY MIL-M-7298 - Manual , Technical , Commercial Equipment. Beneficial comments (recommendations, additions, deletions) and any perti- nent data which may b
4、e of use in improving this document should be addressed to: Defense Personnel Support Center, Directorate of Medical Materiel , DPSC-ATT, 2800 South 20th Street, Philadelphia, PA 19101, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of t
5、his document or by letter. FSC 6520 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M I L - B- 37 295A . STANDARDS FEDERAL FED-STD-66 FED-STD-151 - Metals, Test Methods. - Steel , Chemical Composition and Hardenabi 1 i ty. MILITARY MIL-STD-105 MIL-ST
6、D-129 - Sampling Procedures and Tables for Inspection by - Marking for Shipment and Storage. Attributes. DRAWING , DEFENSE PERSONNEL SUPPORT CENTER (DPSC) 24376 Bath, Water, Dental (Copies of specifications, standards , and drawings required by contractors in connection with specific procurement fun
7、ctions should be obtained. from the .procuring .activity or as directed by the contracting officer. ) cation to the extent specified herein. effect on date of invitation for bid or request for proposal shall apply. 2.2 Other publications. The following documents form a part of this specifi- Unless o
8、therwise indicated, the issue in UNDERWRITERS LAQORATORIES, INC. (UL) Underwriters Laboratories , Inc Standards (Application for copies should be addressed to the Underwriters Laboratories, Inc., 207 East Ohio Street, Chicago, IL 60611, 333 Pfingsten Road, Northbrook, IL 60062, 1285 Walt Whitman Roa
9、d, Melville, LI, NY 11746, 1655 Scott Blvd., Santa Clara, CA 95050.) AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI 1 C73.11 . - Plugs andiReceptacles - General Purpose, 125 Volts, 15 Amperes, 2 Pole, 3 Wire, Grounding Type. (Application for copies should be addressed to the American National Standards
10、 Institute, 1430 Broadway, New York, NY 10018.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - . MIL-B-37295A 3. REQUIREMENTS 3.1 Fire and casualty hazards, 3.1.1 Prior to delivery, the contractor shall submit proof to the contracting agency th
11、at the equipment he will supply under this specification conforms to the applicable requirements of Underwriters Laboratories , Inc. (UL) Standards. The label or listing of the UL may be accepted as evidence that the equipment conforms to this requirement. 3.1.2 In lieu of the label or listing, the
12、contractor may submit in- dependent proof satisfactory to the contracting agency, prior to delivery, that his equipment conforms to UL Standards. does not absolve the contractor from complete compliance wih the require- ments of this specification in order to secure the acceptance of this commodity.
13、 specified herein. Materials not specifically designated shall be of high commercial quality throughout and shall be entirely suitable for the intended purpose. water bath and shall be capable of heating water to a thermostatically controlled temperature ranging from 90 to 160 degrees Fahrenheit (OF
14、). configuration and fit of all components shall eliminate any cracks and crevices in which materials might collect, and the bath shall be readily cleanable by conventional means. The water bath shall be suitable for operation on 115 volt, 60 hertz alternating current. The water bath shall be in com
15、pliance with Defense Personnel Support Center (DPSC) Drawing No. 24376. 3.1.3 . Compliance with UL requirements regarding fire and casualty hazards 3.2 Materials. Materials shall conform to the applicable requirements . 3.3 Design and construction. The water bath shall be a low temperature The 3.3.1
16、 Cabinet. The cabinet shall be a spot welded assembly of a frame stamping, a top stamping, and a ground clip, together with the necessary angles and weld nuts. The frame and top stampings shall be fabricated of no. 22 (.O31 inch) U.S. Standard Gauge 18-8 stainless steel sheets. The exterior of the c
17、abinet shall be finished in a no. 4 or brush finish. 3.3.2 Heating element. The-strip heater shall be attached in the well of the cabinet with screws and shall be spatially suspended by spacers. strip heater shall be rated at 211 watts plus or minus 10 percent at 115 volt, 60 hertz alternating curre
18、nt. The heater shall consist of nickel chromium alloy wire, imbedded in compressed refractory material and enclosed in a chrome steel housing. The 3. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IMIL-B-37275A 65 M 7779706 02b577b b m. M I L - B- 3
19、7 2 9 5A 3.3.3 Main switch. The on-off switch shall be a four position, double pole, single throw, rotary switch with a 15 ampere, 125 volt alternating current rating and shall serve as a total disconnecting switch. An on-off switch knob shall be keyed to the switch and imprinted “ON-OFF-ON-OFF“ at
20、the four reciprocating positions of. the switch. 3.3.4 Thermostat. The thermostat shall be of the strut-type construction and shall be enclosed in a stainless steel case. The thermoswitch shall be mounted on the wall of the cabinet well and the adjusting stem shall protrude through an elongated hole
21、 in the front panel of the cabinet. The thermoswitch shall have a 10 ampere, 155 volt AC rating. 3.3.5 Dial. The dial may serve a multiple function as a temperature reference and as anidentification nameplate (see 3.7). thermoswitch stem and shall be mounted on the front panel of the cabinet. temper
22、ature numbers shall be printed at intervals of 2OoF or less starting at 1OOOF or less and ending at 16OoF or more. A thermoswitch knob shall be attached to the thermoswitch stem and shall be rotatably adjustable to the temperature selections. The dial shall be placed over the The 3.3.6 Pilot lights.
23、 The two pilot lamps shall be of the neon type with a nylon body and a red plstic lens. thermoswitch contacts are closed and activating the strip heater. lamp shall indicate continuously when the on-off switch is turned to “ON“. B&S Gauge aluminum sheet. The bottom panel shall be securely attached t
24、o the . cabinet. Each corner of the bottom panel shall have a securely attached leg with a polyethylene cap to properly contact the surface on which it is resting without wobble or other imbalance. One pilot lamp shall indicate only when the The other pilot The bottom panel shall be fabricated of no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILB37295A1978BATHWATERDENTALIMPRESSIONMATERIALLOWTEMPERATURE 低温 牙科 印模材料 浴缸 PDF

链接地址:http://www.mydoc123.com/p-689543.html