DLA DSCC-DWG-04034 REV B-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED LIGHT WEIGHT COPPER CONDUCTOR TIN COATED 150 DEGREE C 600 VOLT.pdf
《DLA DSCC-DWG-04034 REV B-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED LIGHT WEIGHT COPPER CONDUCTOR TIN COATED 150 DEGREE C 600 VOLT.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-04034 REV B-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED LIGHT WEIGHT COPPER CONDUCTOR TIN COATED 150 DEGREE C 600 VOLT.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、REVISIONS LTR DESCRIPTION DATE APPROVED A Technical modifications to agree with SAE-AS22759/80. Editorial changes throughout. Update format. Added approved supplier. 3/1/2009 Abdo Abdouni B Added approved supplier. 8 September 2010 Abdo Abdouni Prepared in accordance with ASME Y14.100 Selected item
2、drawing REV PAGE REV STATUS OF PAGES REV B A A A A A A A B B PAGE 1 2 3 4 5 6 7 8 9 10 PMIC PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 William Carpenter Original date of drawing 12 July 2004 CHECKED BY TITLE Lee Surowiec WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE
3、/POLYIMIDE INSULATED, LIGHT WEIGHT, COPPER CONDUCTOR, TIN COATED, 150C, 600 VOLT APPROVED BY Richard L. Taylor SIZE CAGE CODE DWG. NO. 04034 A 037Z3 REV B PAGE 1 OF 10 AMSC N/A 6145-E096-001.CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990
4、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04034 REV A PAGE 2 1 SCOPE 1.1 Scope. This drawing covers the performance characteristics for a composite wire usi
5、ng a seamless polytetrafluoroethylene/ hydrolysis resistant polyimide tape wrap insulation system, with a light weight stranded conductor. 1.2 Part or Identifying Number (PIN). The complete PIN should be as follows: 04034 - 20 - 9 FP Fluorocarbon Polymer, modified Polytetrafluoroethylene (PTFE) FIGU
6、RE 1. General configuration. Wire size (see table I) DSCC drawing number FP / POLYIMIDE / FP TAPE Insulation color designator (see table I) FP TAPE CONDUCTOR, STRANDED, SMALL DIAMETER TIN COATED COPPER Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
7、DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04034 REV A PAGE 3 TABLE I. Details of construction. PIN Wire size (AWG) Conductor Finished wire Stranding (number of strands X gauge (AWG) of strands) Diameter (inches) Resistance at 20C ohms/1000ft. (max) Diamet
8、er (inches) Weight lb/1000ft. (max) Min Max Min Max 04034-26-* 26 19 X 38 .0175 .0204 41.3 .030 .034 1.43 04034-24-* 24 19 X 36 .0225 .0244 26.2 .034 .038 1.93 04034-22-* 22 19 X 34 .0285 .0314 16.2 .040 .043 2.85 04034-20-* 20 19 X 32 .0365 .0394 9.88 .048 .051 4.38 04034-18-* 18 19 X 30 .0455 .049
9、4 6.23 .056 .060 6.60 04034-16-* 16 19 X 29 .0515 .0554 4.81 .063 .067 8.30 04034-14-* 14 19 X 27 .0645 .0694 3.06 .076 .080 12.6 04034-12-* 12 37 X 28 .0835 .0894 2.02 .096 .100 19.6 04034-10-* 10 37 X 26 .106 .112 1.26 .119 .123 30.6 * The asterisks in the PIN column of table I should be replaced
10、by color code designators (see 1.2.2). Example: 04TBD-26-93 is white with an orange stripe. 1.2.1 Color. The wire insulation color should be indicated by the color designator (see 1.2) and as specified in the contract or purchase order. The insulation color should be in accordance with MIL-STD-681,
11、system 1, differentiation color coding chassis wiring (3 numbers maximum). For laser marked wires, color limits should be in accordance with MIL-STD-104, class I, or in accordance with table V of this drawing. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.2 Specifications, standards, and handb
12、ooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-104 - Limits for Electrical Ins
13、ulation Color MIL-STD-2223 - Test Methods for Insulated Electric Wire (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-government publications.
14、The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM B33 - Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical
15、Purposes ASTM D3032 - Standard Test Methods for Hookup Wire Insulation ASTM D4591 - Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry (Copies of these documents are available from http:/www.astm.org/ or ASTM Internationa
16、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, Pennsylvania, USA 19428-2959.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04034 REV A PAGE 4 NCSL IN
17、TERNATIONAL NCSL-Z540.3 - General Requirements for Calibration of Measuring and Test Equipment (Copies of these documents are available online at http:/www.ncsli.org or from NCSL International 2995 Wilderness Place, Suite 107 Boulder, Colorado 80301-5404.) SAE INTERNATIONAL SAE-AS4373 - Test Methods
18、 for Insulated Electric Wire SAE-AS22759 - Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy SAE-AS22759/80 - Wire, Electrical, Polytetrafluoroethylene/polyimide Insulated, Lightweight, Tin-coated, copper conductor 150 C, 600 Volts (Copies of these documents are available from http:/
19、www.sae.org/ or SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001). 3. REQUIREMENTS 3.1 DSCC requirements. Items described in this shall meet the requirements of SAE-AS22759 and SAE-AS22759/80 except as specified herein. Any requirements included in this drawing shall be in additi
20、on to, or supersede those requirements included in SAE-AS22759 and SAE-AS22759/80. In case of conflict between the requirements in this drawing, SAE-AS22759 and SAE-AS22759/80, the requirements of this drawing shall take precedence. 3.2 Design configuration. The design, construction, and physical di
21、mensions shall be as specified in this drawing. 3.2.1 Design documentation. Design documentation shall be shall be retained by the manufacturer, and shall be available upon request for review by the contracting activity, DSCC, or contractor. 3.3 Material. 3.3.1 Conductor. Conductors shall be made of
22、 soft annealed copper wire in accordance with ASTM B33 and table I of this drawing. All strands shall be free from lumps, kinks, splits, scarred or corroded surfaces and skin impurities. Strands shall be tin coated in accordance with ASTM B33. 3.3.2 Insulation. Insulation shall be polytetrafluoroeth
23、ylene and polytetrafluoroethylene/polyimide tape as specified in tables II and III. The polyimide tape shall be hydrolysis resistant. TABLE II. Wire insulation materials. 1/ Tape code Thickness nominal (inches) Material 1 2 3 .0012 .0020 .0025 .00045 FP/.00065 polyimide/.0001 FP FP (Unsintered) FP (
24、Unsintered) 1/ Physical properties of PTFE unsintered tape shall be in accordance with SAE-AS22759. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04034 REV A PAG
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG04034REVB2010WIREELECTRICALCOMPOSITEPOLYTETRAFLUOROETHYLENEPOLYIMIDEINSULATEDLIGHTWEIGHTCOPPERCONDUCTORTINCOATED150DEGREEC600VOLTPDF

链接地址:http://www.mydoc123.com/p-688580.html