DIN EN ISO 24157-2008 Ophthalmic optics and instruments - Reporting aberrations of the human eye (ISO 24157 2008) English version of DIN EN ISO 24157 2008-11《眼科光学器件和仪器 人眼的失常报告》.pdf
《DIN EN ISO 24157-2008 Ophthalmic optics and instruments - Reporting aberrations of the human eye (ISO 24157 2008) English version of DIN EN ISO 24157 2008-11《眼科光学器件和仪器 人眼的失常报告》.pdf》由会员分享,可在线阅读,更多相关《DIN EN ISO 24157-2008 Ophthalmic optics and instruments - Reporting aberrations of the human eye (ISO 24157 2008) English version of DIN EN ISO 24157 2008-11《眼科光学器件和仪器 人眼的失常报告》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、November 2008DEUTSCHE NORM English price group 16No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 11.040.70!$Rdn“147657
2、5www.din.deDDIN EN ISO 24157Ophthalmic optics and instruments Reporting aberrations of the human eye (ISO 24157:2008)English version of DIN EN ISO 24157:2008-11Augenoptik und ophthalmische Instrumente Verfahren zur Darstellung von Abbildungsfehlern des menschlichen Auges(ISO 24157:2008)Englische Fas
3、sung DIN EN ISO 24157:2008-11www.beuth.deDocument comprises 36 pagesDIN EN ISO 24157:2008-11 2 National foreword This standard has been prepared by Technical Committee ISO/TC 172 “Optics and photonics”, Subcommittee SC 7 “Ophthalmic optics and instruments” in collaboration with Technical Committee C
4、EN/TC 170 “Ophthalmic optics” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was the Normenausschuss Feinmechanik und Optik (Optics and Precision Mechanics Standards Committee). The DIN Standard corresponding to the International Standard referred to in this doc
5、ument is as follows: ISO 8429 DIN EN ISO 8429 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. National Annex NA (informative) Bibliography DIN EN ISO
6、 8429, Optics and optical instruments Ophthalmology Graduated dial scale EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 24157July 2008ICS 11.040.70English VersionOphthalmic optics and instruments - Reporting aberrations ofthe human eye (ISO 24157:2008)Optique et instruments ophtalmiques - Mth
7、odes de Augenoptik und ophthalmische Instrumente - Verfahren zurDarstellung von Abbildungsfehlern des menschlichenAuges (ISO 24157:2008)This European Standard was approved by CEN on 29 May 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions f
8、or giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official
9、 versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgi
10、um, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STA
11、NDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 24157:2008: Eprsentation des aberrations de loeil
12、 humain(ISO 24157:2008)Contents Page 1 2 3 4 5 5.1 5.2 Representation of wavefront data in the form of wavefront gradient fields or wavefront 5.3 6 6.1 6.2 6.3 Aberration data presented in the form of normalized Zernike coefficients given in 6.4 6.5 Annex B (informative) Conversion of Zernike coeffi
13、cients to account for differing aperture sizes, Annex C (informative) Conversion between Zernike coefficients represented in different systems Annex D (informative) Computer algorithm to generate partial derivative weighting matrices for 2 DIN EN ISO 24157:2008-11 EN ISO 24157:2008 (E)Foreword. 3 Sc
14、ope . 4 Normative references . 4 Terms and definitions. 4 Coordinate system 8 Representation of wavefront data. 9 Representation of wavefront data with the use of Zernike polynomial function coefficients 9 error function values 12 Gradient fit error . 13 Presentation of data representing the aberrat
15、ions of the human eye 13 Aberration data presented in the form of normalized Zernike coefficients 14 General. 13 magnitude/axis form. 14 Aberration data presented in the form of topographical maps . 15 Annex A (informative) Methods of generating Zernike coefficients . 18 Presentation of pooled aberr
16、ation data 17 decentration and coordinate system rotation . 20 of notation . 28 un-normalized Zernike polynomial functions 30 Annex E (informative) Table of normalized Zernike polynomial functions (to 6th radial order) 32 Bibliography . 34 Foreword This document (EN ISO 24157:2008) has been prepared
17、 by Technical Committee ISO/TC 172 “Optics and optical instruments“ in collaboration with Technical Committee CEN/TC 170 “Ophthalmic optics” the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or
18、 by endorsement, at the latest by January 2009, and conflicting national standards shall be withdrawn at the latest by January 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible
19、for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germ
20、any, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 24157:2008 has been approved by CEN as a EN ISO 24157:2008 wi
21、thout any modification. 3 DIN EN ISO 24157:2008-11 EN ISO 24157:2008 (E)1 Scope This International Standard specifies standardized methods for reporting aberrations of the human eye. 2 Normative references The following referenced documents are indispensable for the application of this document. For
22、 dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 8429, Optics and optical instruments Ophthalmology Graduated dial scale 3 Terms and definitions For the purposes of this document, the foll
23、owing terms and definitions apply. Symbols used are summarized in Table 1. 3.1 line of sight line from the point of interest in object space to the centre of the entrance pupil of the eye and continuing from the centre of the exit pupil to the retinal point of fixation (generally the foveola) 3.2 Ze
24、rnike polynomial function one of a complete set of functions defined and orthogonal over the unit circle, the product of three terms, a normalization term, a radial term and a meridional term, parameterized by a dimensionless radial parameter, , and a dimensionless meridional parameter, , designated
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINENISO241572008OPHTHALMICOPTICSANDINSTRUMENTSREPORTINGABERRATIONSOFTHEHUMANEYEISO241572008ENGLISHVERSIONOFDINENISO24157200811

链接地址:http://www.mydoc123.com/p-682638.html