DIN EN 13201-3-2016 Road lighting - Part 3 Calculation of performance German version EN 13201-3 2015《路灯 第3部分 性能的计算 德文版本EN 13201-3-2015》.pdf
《DIN EN 13201-3-2016 Road lighting - Part 3 Calculation of performance German version EN 13201-3 2015《路灯 第3部分 性能的计算 德文版本EN 13201-3-2015》.pdf》由会员分享,可在线阅读,更多相关《DIN EN 13201-3-2016 Road lighting - Part 3 Calculation of performance German version EN 13201-3 2015《路灯 第3部分 性能的计算 德文版本EN 13201-3-2015》.pdf(65页珍藏版)》请在麦多课文档分享上搜索。
1、June 2016 English price group 23No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 93.080.40!%Vuk“2518272www.din.deDIN
2、 EN 13201-3Road lighting Part 3: Calculation of performance;English version EN 13201-3:2015,English translation of DIN EN 13201-3:2016-06Straenbeleuchtung Teil 3: Berechnung der Gtemerkmale;Englische Fassung EN 13201-3:2015,Englische bersetzung von DIN EN 13201-3:2016-06Eclairage public Partie 3: Ca
3、lcul des performances;Version anglaise EN 13201-3:2015,Traduction anglaise de DIN EN 13201-3:2016-06SupersedesDIN EN 13201-3:2004-04 andDIN EN 13201-3 Corrigendum 1:2007-07www.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.
4、Document comprises 65 pages 06.16 2 A comma is used as the decimal marker. National foreword This document (EN 13201-3:2015) has been prepared by Technical Committees CEN/TC 169 “Light and lighting” (Secretariat: DIN, Germany), Joint Working Group WG 12 with Technical Committee CEN/TC 226 “Road ligh
5、ting” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was DIN-Normenausschuss Lichttechnik (DIN Standards Committee Lighting Technology), Working Committee NA 058-00-11 AA FNL/FGSV 3.02 Auen-beleuchtung. Amendments This standard differs from DIN EN 13201-3:2004-
6、04 and DIN EN 13201-3 Corrigendum 1:2007-07 as follows: a) to terminate the calculation before reaching a distance of 500 m, in the calculation of veiling luminance, Lv, the contribution of at least 2 % of the next luminaire in the row is no longer to be tested (this is to avoid ambiguous interpreta
7、tions that can produce different results from different software); b) the default option is about 500 m, but there is an alternative to retain only the luminaires of a shorter installation. This last case should be clearly mentioned in the lighting design by the number of luminaires involved in the
8、calculation of fTI; c) there is a new formula for calculating veiling luminance Lvfor a wider range of values. Thus, the case where luminaires could be very near to the axis of vision of the observer (0,1 20 lx Number of decimal places 2 2 2 0 2 2 1 0 5 Photometric data 5.1 General Photometric data
9、for the light distribution of the luminaires used in the lighting installation are needed for calculating the lighting quality characteristics in this standard. These data are in the form of an intensity table (I-table) which gives the distribution of luminous intensity emitted by the luminaire in a
10、ll relevant directions. When luminance calculations are to be made, photometric data for the light reflecting properties of the road surface are required in the form of an r-table. Interpolation is needed in using both these tables to enable values to be estimated for directions between the tabulate
11、d angles. 5.2 The I-table 5.2.1 System of coordinates and advised angular intervals of the I-table For calculations made in accordance with this standard, an intensity table (I-table) that describes the behaviour of the luminaire with the required accuracy by the aim of calculation shall be used. Th
12、is I-table shall be prepared in accordance with EN 13032-1. The coordinate system used for road lighting luminaires is the C-planes system, shown in Figure 1. For floodlight installations, the intensity distribution measured in the B-planes system may be accepted if the calculation program can trans
13、fer the intensity values in the C-planes system. In Figure 1, the luminaire is shown at its tilt during measurement. Luminous intensity shall be expressed in candelas. The luminous flux used in calculation shall be declared in the calculation report. Unless specific conditions are mentioned in the c
14、alculation report, the luminous flux used shall be that of the light source mentioned in the data sheet of the luminaire. If the luminous intensity table is given in candelas per kilolumen (cdklm1), its values shall be converted in candelas, considering the luminous flux of all the light sources in
15、the luminaire. DIN EN 13201-3:2016-06 EN 13201-3:2015 (E) 13 Key 1 luminaire at tilt during measurement 2 longitudinal direction 3 vertical direction 4 direction of luminous intensity Figure 1 Orientation of C, coordinate system in relation to longitudinal direction of carriageway Maximum angular in
16、tervals stipulated in this standard have been selected to give acceptable levels of interpolation accuracy. In the (C, ) system of coordinates, luminous intensities shall be provided at the angular intervals stated below. For all luminaires the angular intervals in vertical planes () shall at most b
17、e 2,5 from 0 to 180. In azimuth the intervals shall be varied according to the symmetry of the light distribution from the luminaire as follows: a) luminaires with no symmetry: the intervals shall at most be 5, starting at 0, when the luminaire is at its tilt during measurement, and ending at 355; b
18、) luminaires with nominal symmetry about the C = 270 90 plane: the intervals shall at most be 5, starting at 270, when the luminaire is at its tilt during measurement, and ending at 90; c) luminaires with nominal symmetry about the C = 270 90 and C = 0 180 planes: the intervals shall at most be 5, s
19、tarting at 0, when the luminaire is at its tilt during measurement, and ending at 90; d) luminaires with nominally the same light distribution in all C-planes: only one representative set of measurements in a vertical (C-plane) is needed. DIN EN 13201-3:2016-06 EN 13201-3:2015 (E) 14 Where standards
20、 for specific luminaire typologies exist and prescribe improved angular intervals these shall be applied. The angular intervals stated above shall be reduced in case of a great gradient variation of consecutive luminous intensities. NOTE In that case, it is the role of photometric laboratories to pr
21、ovide the I-table with relevant reduced angular intervals defined from the angles included in the photometric file. 5.2.2 Linear interpolation in the I-table To estimate the luminous intensity I(C, ) in the direction (C, ), it is necessary to interpolate between four values of luminous intensity lyi
22、ng closest to the direction, see Figure 2 and Figure 3. Figure 2 Angles required for linear interpolation of luminous intensity DIN EN 13201-3:2016-06 EN 13201-3:2015 (E)15 Figure 3 Angles required for linear interpolation of luminous intensity (from Figure 2 but showing intensity on z-axis in persp
23、ective) For this purpose, the following formulae or mathematically equivalent formulae shall be used: Interpolation on C angles ( ) ( )( ) ( ) m1mmjmjmjmj,1,CCCCCICICICI=+(3) where I(Cm, j) indicates the intensity in column number m and row number j of the I-table, and so on for the other similar sy
24、mbols; C is the azimuth, measured about the first photometric axis; is the vertical angle measured from the first photometric axis; j, m, m+1 are integers indicating the number of the column or row in the I-table. From which: ( ) ( ) ( ) ( )( )jmj1mm1mmjmj, CICICCCCCICI +=+(4) Similarly: ( ) ( )( )
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN1320132016ROADLIGHTINGPART3CALCULATIONOFPERFORMANCEGERMANVERSIONEN1320132015 路灯 部分 性能 计算 德文 版本 EN1320132015PDF

链接地址:http://www.mydoc123.com/p-665795.html