DIN EN 1319-2010 Domestic gas-fired forced convection air heaters for space heating with fan-assisted burners not exceeding a net heat input of 70 kW German version EN 1319 2009《有鼓.pdf
《DIN EN 1319-2010 Domestic gas-fired forced convection air heaters for space heating with fan-assisted burners not exceeding a net heat input of 70 kW German version EN 1319 2009《有鼓.pdf》由会员分享,可在线阅读,更多相关《DIN EN 1319-2010 Domestic gas-fired forced convection air heaters for space heating with fan-assisted burners not exceeding a net heat input of 70 kW German version EN 1319 2009《有鼓.pdf(156页珍藏版)》请在麦多课文档分享上搜索。
1、October 2010 Translation by DIN-Sprachendienst.English price group 35No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 97.100.20!$kV|“1725189www.din.deDDIN EN 1319Domestic gas-fired forced convection air heaters for space heating, withfan-assisted burners not exceeding a net heat input of 70 kWEnglish translation of DIN EN 1319:2010-10Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Rumen fr denhuslich
3、en Gebrauch, mit geblseuntersttzten Gasbrennern mit einerNennwrmebelastung gleich oder kleiner als 70 kWEnglische bersetzung von DIN EN 1319:2010-10Gnrateurs dair chaud convection force utilisant les combustibles gazeux pour lechauffage de locaux usage dhabitation, comportant des brleurs avec ventil
4、ateur dedbit calorifique infrieur ou gal 70 kW (sur pouvoir calorifique infrieur)Traduction anglaise de DIN EN 1319:2010-10SupersedesDIN EN 1319:2010-06www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.15609.10 DIN EN 1319:2010-10 A
5、comma is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 180 “Domestic and non-domestic gas-fired air heaters and non-domestic gas-fired overhead radiant heaters” (Secretariat: AFNOR, France). The responsible German body involved in its pre
6、paration was the Normenausschuss Gastechnik (Gas Technology Standards Committee). This standard includes safety requirements. It is intended to include this standard in the body of Codes of practice for gas issued by the DVGW Deutscher Verein des Gas- und Wasserfaches e.V. (German Technical and Scie
7、ntific Association for Gas and Water). Amendments This standard differs from DIN EN 1319:2002-01 as follows: a) requirements for combustion products evacuation ducts (POCEDs), supplied as an integral part of the system, have been incorporated; b) the standard has been brought in line with EN 437:200
8、3. Compared with DIN EN 1319:2010-06, the following corrections have been made to the German version only and therefore do not affect the English text: Subclause 6.1.1.2.1 the title of the subclause has been changed to read: “Gerte der Bauarten B12, B13, B42und B43” Subclause 6.1.6.2.1, 1st sentence
9、: the sentence has been changed as follows: “Die Kohlenstoffmonoxidkonzentration der trockenen, luftfreien Abgase darf 0,10 % nicht berschreiten, wenn das Gert mit Normprfgas unter den in 7.3.6.4.1 angegebenen Bedingungen betrieben wird.” Subclause 7.1.2, list item c), 1st sentence: the sentence has
10、 been changed as follows: “c) fr die mit den Normprfgasen G 2 oder G 25 durchzufhrenden Prfungen ein Gas zu verwenden, das den Gruppen H oder E angehrt, .” Subclause 7.3.2.1, Equation (8) the equation has been changed as follows: ppppppddawwah+=622,0)(2 DIN EN 1319:2010-10 Subclause 7.3.5.2.1.2, Tes
11、t No. 2, 1st sentence: the sentence has been changed as follows: “Ohne die Voreinstellung des Brenners und Zndbrenners zu ndern, wird das Gert mit dem Normprfgas betrieben, wobei der Druck am Gerteeingang auf den in 7.1.4. angegebenen Mindestdruck herabgesetzt wird.” Subclause 7.3.9.1, 4th paragraph
12、: the paragraph has been changed as follows: “Die Dichtheit des Raumes muss derart sein, dass nach Erreichen einer homogenen Raumkonzentration von 4,0 % CO2die Abnahme nicht ber 0,15 % nach einer einstndigen Zeitspanne liegen darf.” Table A.4, Category: I3P(B/P) Column: Grenzgas unvollstndige Verbre
13、nnung the entry has been changed to read: “G 31, G 30” Table A.4, Category: II2E3P Column: Normprfgas the entry has been changed to read: “G 20, G 31” Table A.4, Category: II2E3P Column: Grenzgas Russbildung the entry has been changed as follows: “ - ” Table A.4, Category: II2ELs3B/P Column: Normprf
14、gas the entry has been changed to read: “G 20, G 2.350, G 30” Table A.4, Category: II2ELs3B/P Column: Grenzgas Abheben the entry has been changed to read: “G 2.352, G 31” Subclause A.4.2.3.2, to “Category II2S3B”, 2nd sentence: the sentence has been changed as follows: “Die Gase der zweiten Familie
15、werden unter den gleichen Bedingungen verwendet wie fr die Kategorie I2S.” Subclause A.4.2.3.2, to “Category II2HS3B/P”, 2nd sentence: the sentence has been changed as follows: “Die Gase der zweiten Familie werden unter den gleichen Bedingungen verwendet wie fr die Kategorie I2HS.” 3 DIN EN 1319:201
16、0-10 4 Subclause A.4.2.3.2, to “Category II2HS3B”, 2nd and 3rd sentences: the sentences have been changed as follows: “Die Gase der zweiten Familie werden unter den gleichen Bedingungen verwendet wie fr die Kategorie I2HS. Die Gase der dritten Familie werden unter den gleichen Bedingungen verwendet
17、wie fr die Kategorie I3B.” Subclause A.4.2.3.2, to “Category II2E3P(B/P)”, 2nd sentence: the sentence has been changed as follows: “Die Gase der zweiten Familie oder die damit verbundenen Gase werden unter den gleichen Bedingungen verwendet wie fr die Kategorie I2E.” Table A.6, head of the table, (2
18、nd column): the head of the table has been changed to read: “Kategorie I3+, I3P, I3B, I3B/P” Table F.7, 1st column, 2nd row: the entry has been changed to read: “% (CO2)N(neutrale Verbrennung)” Table ZB.1, 1st column, 3rd row: the entry has been changed to read: “Feuerwiderstand, Russbrand Russ- und
19、 Feuerfestigkeit Vollstndigkeit E und Isolierung I Klassifizierung O und Erklrung des Abstandes zu brennbarem Material” Table ZB.1, footnote b: the footnote has been changed to read: “Russbestndigkeit, Brandbestndigkeit G fr Gasgerte nicht anwendbar.” Previous editions DIN EN 1319: 1998-10, 1999-10,
20、 2002-01, 2010-06 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1319 December 2009 ICS 97.100.20 Supersedes EN 1319:1998English Version Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW Gnrateurs dair chaud co
21、nvection force utilisant les combustibles gazeux pour le chauffage de locaux usage dhabitation, comportant des brleurs avec ventilateur de dbit calorifique infrieur ou gal 70 kW (sur pouvoir calorifique infrieur) Warmlufterzeuger mit erzwungener Konvektion zum Beheizen von Rumen fr den huslichen Geb
22、rauch, mit geblseuntersttzten Gasbrennern mit einer Nennwrmebelastung gleich oder kleiner als 70 kW This European Standard was approved by CEN on 1 November 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standar
23、d the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French,
24、German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Cze
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN13192010DOMESTICGASFIREDFORCEDCONVECTIONAIRHEATERSFORSPACEHEATINGWITHFANASSISTEDBURNERSNOTEXCEEDINGANETHEATINPUTOF70KWGERMANVERSIONEN13192009

链接地址:http://www.mydoc123.com/p-665773.html