《DIN EN 12543-5-1999 Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 5 Measurement of the effective fo.pdf》由会员分享,可在线阅读,更多相关《DIN EN 12543-5-1999 Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 5 Measurement of the effective fo.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes English version of DIN EN 12543-5 ICs 19.100 DIN - EN 12543-5 Zerstrungsfreie Prfung - Charakterisierung von Brennfle
2、cken in Industrie-Rntgenanlagen fr die zerstrungsfreie Prfung - Teil 5: Messung der effektiven Brennfleckgre von Mini- und Mikrofokus- Rntgenrhren European Standard EN 12543-5 : 1999 has the status of a DIN Standard. A comma is used as the decimal marker. National foreword This standard has been pre
3、pared by CEN/TC 138. The responsible German body involved in its preparation was the Normenausschu Materialprfung (Mate- rials Testing Standards Committee), Technical Committee Durchstrahlungsprfung und Strahlenschutz. EN comprises 6 pages. No pari of this standard may be reproduced without the prio
4、r permission of Y Deutsches Institut fr Normung e. V., Berlin. wth Verlag GmbH, D-10772 Berlin, has the exclusive right of sale for German Standards (DIN-Normen). Ref. No. DIN EN 12543-5 : 1999-1 English price group 06 Sales No. 1106 05.00 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12543-5
5、 September 1999 ICs 19.1 O0 English version Non-destructive testing Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes Essais non destructifs - Caractris- tiques des fo
6、yers missifs des tubes radiognes industriels utiliss dans les essais non destructifs - Partie 5: Mesure de la dimension du foyer missif de tubes radiognes mini et micro foyer Rntgenrhren Zerstrungsfreie Prfung - Charakterisierung von Brennflecken in Industrie-Rntgenanlagen fr die zerstrungsfreie Prf
7、ung - Teil 5: Messung der effektiven Brennfleck- gre von Mini- und Mikrofokus- This European Standard was approved by CEN on 1999-08-1 6. CEN members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
8、 standard without any alteration. Up-to-date lists and bibliographical references concerning such national stand- ards may be obtained on application to the Central Secretariat or to any CEN member. The European Standards exist in three official versions (English, French, German). A version in any o
9、ther language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germ
10、any, Greece, Iceland, Ireland, Italy, Luxembourg, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom. CEN European Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr Normung Central Secretariat: rue de Stassart 36, B-1050 Brussels O
11、 1999. CEN - All rights of exploitation in any form and by any means reserved worldwide for CEN national members. Ref. No. EN 12543-5 : 1999 E Page 2 EN 12543-5 : 1999 Contents Page Foreword 2 Introduction . 3 1 Scope . 3 2 Normative references , . 3 3Termsanddefinitions 3 4Testmethod 3 5 Measuremen
12、t and determination of the focal spot size 5 Foreword This European Standard has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing“, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an
13、identical text or by endorsement, at the latest by March 2000, and conflicting national standards shall be withdrawn at the latest by March 2000. According to the CENKENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Sta
14、ndard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netheriands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. In the framework of its scope, Technical Committee CENTTC 138 entrusted CENITC 138NVG 1 “ionizing
15、 Radiation“ with preparing the following standard: EN 12543-5, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes. EN 12543-5 is a part of
16、series of European Standards with the same number: the other parts are the following: EN 12543-1, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part I: Scanning method EN 12543-2, Non-destructive testing - Characteristics o
17、f focal spots in industrial X-ray systems for use in non- destructive testing - Part 2: Pinhole camera radiographic method EN 12543-3, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 3: Slit camera radiographic method EN
18、 12543-4, Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non- destructive testing - Part 4: Edge method Page 3 EN 12543-5 : 1999 Introduction In order to cover the different requirements for focal spot size measurement, five different methods are desc
19、ribed in EN 12543-1 to EN 12543-5. The scanning method (EN 12543-1) is dedicated to those applications where quantitative values for the intensity distribution and spot sizes are needed, i. e. calibration and image processing purposes. The radiographic methods (EN 12543-2 and EN 12543-3) describe th
20、e traditional techniques and are dedicated for certification purposes and for field application up to 200 kV. Where no pinhole or slit cameras are available in the field, the edge method (EN 12543-4) may be applied. It repre- sents a very simple method for field application. In order to cover also t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN1254351999NONDESTRUCTIVETESTINGCHARACTERISTICSOFFOCALSPOTSININDUSTRIALXRAYSYSTEMSFORUSEINNONDESTRUCTIVETESTINGPART5MEASUREMENTOFTHEEFFECTIVEFOPDF

链接地址:http://www.mydoc123.com/p-664866.html