1、UDC 621.643.2-034: 620.179.147 DEUTSCHE NORM February 1987 Non-destructive testing Eddy current testing of pipes and tubes Procedure DIN 54 141 Part 3 Zerstrungsfreie Prfung; Wirbelstromprfung von Rohren; Durchfhrung der Wirbelstromprfung in keeping with current practice in standards published by th
2、e international Organization for Standardization (ISO), a comma has been used throughout as the decimal marker. 1 Field of application This standard applies to the nondestructive testing of ferromagnetic and non-ferromagnetic pipes and tubes (shortened below to “tubes“) with a diameter between 4 and
3、 150 mm and 0,5 to 5 mm wall thickness, using external or internal concentric test coils and the single- frequency method. It is to be used for in-process control of tubes or for tubes as installed (e.9. condenser tubes or steam generator tubes). 2 Scope This standard specifies the procedure for edd
4、y current testing. The principles of determining the properties of test coils, the relevant diagrams and the procedure of determining the test parameters are given in appendix A, whilst in appendix B, by way of example, the specifica- tions given in appendix A are applied to a set task. Appendix C g
5、ives a table correlating the specifications of Parts 2 and 3 of DIN 54 141. 3 Principle An eddy current test includes the following steps: a) Calibration of test equipment for a set task, .e. selec- tion and arrangement of equipment (see clause 6) and setting of equipment (see clause 71, taking into
6、 account the specifications given in the relevant prod- uct standard (see subclause 4.1 ). Other test param- eters are at the discretion of the person responsible for the test (see subclause 4.2), while all rules of a general nature relating to the test procedure as speci- fied in clause 5,are to be
7、 complied with. b) Routine calibration checking and verification of test c) Preparation of a test report (see clause 9). (see clause 8). 4 Test specifications 4.1 Required information Product related test specifications shall at least include the following data in respect of the test: a) scope of te
8、st specification; b) condition of tubes to be tested; c) reference standards (e.g. holes, grooves); d) evaluation and assessment. In addition, details should be given on any additional dressing and retesting of tubes that may be necessary. 4.2 Other test parameters Where the eddy current test equipm
9、ent and the test frequency are not specified in the test specification and no information is given as regards the evaluation proce- dure, it is at the discretion of the person responsible for the test to select and set the test equipment. If this is to be successful, this requires a knowledge of the
10、 charac- teristics of the test equipment and awareness of the problems involved in the set task. Note. To solve the set task, the person responsible for the test must know the natural imperfections that may occur in the tubes (listed for example in a catalogue on defects) and be instructed in the de
11、tectability and the reliability of detection of such imperfections by means of eddy current testing. Continued on pages 2 to 12 Standards referred to DIN 54 140 Part 2 DIN 54 141 Part 1 DIN 54 141 Part 2 Non-destructive testing; inductive methods; concepts Nondestructive testing; eddy current testin
12、g of pipes and tubes; general remarks on testing using concentric test coils and the single-frequency method Non-destructive testing; eddy current testing of pipes and tubes; reference method for the deter- mination and calibration of the properties of eddy current test equipment using concentric te
13、st coils Explanatory notes This standard has been prepard by Working Group Wirbelstromprfung of Technical Committee 824 Elektrische und magnetische Prfverfahren of the Normenausschu Materialprfung (Materials Testing Standards Committee) of DIM Deutsches Institut fr Normung e. V. International Patent
14、 Classification G O1 N 27/90 4th Verlag OrnbH, Berlin, has the exclusive right of sale for German Standards (DIN-NormenJ. DIM 54 141 Part 3 Engl. Price group 9 Sales No. qlO9 .88 Page 2 DIN 54 141 Part 3 The characteristics of the test equipment deter- mined by means of calibration test pieces as sp
15、eci- fied in DIN 54 141 Part 2 can either be directly adopted for the set task, adopted for the set task by using a transfer function or redetermined for the tube to be tested by an analogous method (see appendix C). 5 Procedure The following shall be taken into account when carrying out an eddy cur
16、rent test: the tube and the test coil equipment shall be concen- tric (see subclause 6.3.2); end effects shall be minimized (see subclause 6.6); any deformation shall be avoided when producing calibration standards or reference standards (see sub- clause 7.7.2); the relationship between filter setti
17、ng and test speed shall be taken into account (see subclause 7.2.4); the required magnetic field strength shall be estab- lished (see subclause 7.3); calibration checks shall be made during and after test- ing (see clause 8). Equipment 6.1 Test coil 6.1.1 Types of coil A distinction is made between
18、the following types of coil which shall be selected so as to ensure the best pos- sible interference suppression: a) Absolute coils. These are to be used, for example, for detection of a continuous open weld or similar type of imperfection. The use of such coils normally depends on the disturb- ance
19、s present. Suppression of any interference signals generated is more effective, the smaller the leading edge gradient of the disturbance is, as compared with the effective coil width. The sensitivity for detecting imperfections increases in direct proportion to the leading edge gradient of the imper
20、fection and the effective coil width, and is at its optimum when the length of the imperfection and the effective coil width coincide . For a specific coil type, eddy current test coils are distin- guished by their effective coil width, which largely governs the limit imperfection length and the loc
21、alized resolution (as defined in DIN 54 141 Part 2). If these characteristics have been determined for a cali- bration test piece as specified in DIN 54 141 Part 2, they can be applied to a set task using the procedure described in appendix A or B, and permit an assessment to be made to what extent
22、imperfections can be detected using the coil concerned. 6.1.2 Filling factor To achieve a high test sensitivity the diameter of the test coil is to be matched to that of the tube. Normally, the filling factor, 7, for external test coils (as defined in DIN 54 140 Part 2) lies between 0.5 and 0,9, the
23、 limit values corresponding to the diameter range given in clause 1. b) Differential or multiple differential coils. Note. Filling factors related to the coil inside diameter and those for internal test coils differ from the above values. 6.2 Test equipment By way of example, DIN 54 141 Part 1 illus
24、trates the arrangement of an eddy current test equipment. General characteristics of such an equipment (including test coil assembly and tube transport equipment), deter- mined as specified in DIN 54 141 Part 2, may be applied directly. These are a) the characteristic of the sensitivity setting; b)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN5414131987NONDESTRUCTIVETESTINGEDDYCURRENTTESTINGOFPIPESANDTUBESPROCEDURE 无损 检验 管道 管子 涡流 程序 PDF

链接地址:http://www.mydoc123.com/p-659212.html