DIN 53125-2004 Testing of paper and board - Determination of chloride content in aqueous extracts《纸和纸板的试验 水解萃取物中氯化物含量的测定》.pdf
《DIN 53125-2004 Testing of paper and board - Determination of chloride content in aqueous extracts《纸和纸板的试验 水解萃取物中氯化物含量的测定》.pdf》由会员分享,可在线阅读,更多相关《DIN 53125-2004 Testing of paper and board - Determination of chloride content in aqueous extracts《纸和纸板的试验 水解萃取物中氯化物含量的测定》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、DEUTSCHE NORM March 200453125Document comprises 6 pages. No part of this translation may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung e.V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).Determining
2、 the chloride content of aqueousextracts of paper and boardTranslation by DIN-Sprachendienst.In case of doubt, the German-language original should be consulted as the authoritative text.ICS 85.040; 85.060Prfung von Papier und Pappe Bestimmung des Chloridgehaltes inwssrigen ExtraktenIn keeping with c
3、urrent practice in standards published by the International Organization for Standardization(ISO), a comma has been used throughout as the decimal marker.ForewordThis standard has been prepared by Technical Committee Chemisch-technologische Prfverfahren frPapier, Pappe, Halbstoff und Chemiezellstoff
4、 of the Normenausschuss Materialprfung (Materials TestingStandards Committee).AmendmentsThis standard differs from the August 1985 edition in that a reference to cold water extracts has been addedto clause 4 and the standard has been editorially revised.Previous editionsDIN 53125: 1964-02, 1985-08.1
5、 ScopeThis standard specifies a method of determining the chloride content of aqueous extracts of paper andboard, excluding electrical insulating papers. It may be used by analogy for the analysis of pulp.The method is particularly suitable for determining traces of water-soluble chlorides, but high
6、er chloridecontents can be determined if the titrant concentration is suitably increased.2 Normative referencesThis standard incorporates, by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text, and the titles of t
7、he publications arelisted below. For dated references, subsequent amendments to or revisions of any of these publicationsapply to this standard only when incorporated in it by amendment or revision. For undated references, thelatest edition of the publication referred to applies.Supersedes August 19
8、85edition.English price group 7www.din.dewww.beuth.de11.04 9595155Page 2DIN 53125 : 2004-03DIN 12242-1 Conical ground joints on laboratory glassware Dimensions and tolerancesDIN 53114 Determining the conductivity of aqueous extracts of paper, board and pulp (ISO 6587 : 1980,modified)DIN 53124 Determ
9、ining the pH of aqueous extracts of paper, board and pulpDIN EN 645 Paper and board intended to come into contact with foodstuffs Preparation of a cold waterextractDIN EN 20187 Paper, board and pulps Standard atmosphere for conditioning and testing and procedurefor monitoring the atmosphere and cond
10、itioning of samples (ISO 187 : 1990)DIN EN ISO 186 Paper and board Sampling to determine average quality (ISO 186 : 2002)ISO 719 : 1985 Glass Hydrolytic resistance of glass grains at 98 C Method of test and classification3 ConceptWater-soluble chlorides contentThe chloride content that can be extrac
11、ted with water and potentiometrically determined under the conditionsspecified in this standard.4 PrincipleA sample is reduced in size and 5 g of it are extracted for one hour with 100 ml of hot water. The extract is filteredoff, cooled to ambient temperature and, after adding acetone, its chloride
12、content is determined potentiometri-cally by titration with aqueous silver nitrate solution.For very low chloride contents, back-titration with a sodium chloride solution of the same amount-of-substanceconcentration after adding a known volume of silver nitrate solution is recommended.Cold water ext
13、racts as specified in DIN EN 645 may also be used to determine the chloride content by thismethod.5 ApparatusIn addition to standard laboratory equipment, the following shall be used.a) Analytical balance, capable of being read to an accuracy of 0,1 mg.b) Extraction vessel (e.g. round bottom or coni
14、cal flask), made of glass of hydrolytic resistance grain classISO 719 HGB 1, of nominal volume 100 ml to 500 ml (depending on sample size), fitted with a refluxcondenser, made of glass of hydrolytic grain resistance class ISO 719 HGB 1, having ground glass joints(e.g. DIN 12242 V 29/32 joints) or a
15、riser tube of outside diameter 9 mm with a ground cone and 750 mmlong. Before use, new glassware shall be thoroughly rinsed several times with boiling distilled or deionizedwater.c) Water bath.d) Nutsch filter, fitted with a filter plate of porosity grade 4 and a filter flask.e) Magnetic stirrer.f)
16、Microburette, having 0,01 ml scale intervals and finely drawn tip.g) pH meter, capable of measuring to an accuracy of 1 mV.h) Glass bottle, having a ground glass joint and a soda-lime glass tube.i) Electrodes, for potentiometric titration (e.g. silver/silver chloride mercury/mercury(I) sulfate elect
17、rodesystem or combination electrode). The silver/silver chloride electrode shall be stored in a 1 % potassiumchloride solution.NOTE: If the response of the combination electrode is still poor after being thoroughly cleaned in hot water,leave it for a short time in dilute nitric acid and then rinse i
18、t thoroughly with distilled water. If necessary,activate the electrode by silver plating it, preferably using a 5 % potassium silver cyanide solution,KAg(CN)2, and a direct voltage of 2 V, the electrode to be silver-plated being connected as the cathode anda silver wire as the anode.Top up the 1 mol
19、/l potassium nitrate solution from time to time and store the electrode in a 1 mol/l potassiumnitrate solution to protect the diaphragm.6 Reagents6.1 GeneralOnly analytical grade reagents shall be used and the water used shall be distilled water or fully deionized watermeeting the requirements of DI
20、N 53114 and DIN 53124.The following reagents shall be used.Page 3DIN 53125 : 2004-036.2 Acetone, CH3COCH3, taken from the same stock for the sample and blank tests to allow for any chloridecontent.6.3 0,0025 mol/l sodium chloride solution, prepared by dissolving 0,5845 g of sodium chloride, NaCl, in
21、water, making the solution up to the mark with water in a 100 ml volumetric flask, shaking and then pipetting25 ml of this stock solution into a 1000 ml volumetric flask, making up to the mark with water and mixing.6.4 Nitric acid solution, prepared by mixing one part by volume of nitric acid having
22、 a density of 1,40 g/mlwith one part by volume of water.6.5 0,0025 mol/l silver nitrate solution, prepared by dissolving 1,699 g of silver nitrate, AgNO3, in water,pipetting 25 ml of this stock solution into a volumetric flask and making up to 1 l with water. The solution shallbe stored in the dark.
23、1 ml of 0,0025 mol/l silver nitrate solution is equivalent to 0,0886 mg of chloride.7 Sampling and sample preparationCollect an average sample as specified in DIN EN ISO 186, choosing the sample size to suit the batch size andthe mass of sample material per unit area. Analyse at least ten samples re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便