CLC TS 50625-3-1-2015 Collection logistics & treatment requirements for WEEE - Part 3-1 Specification for de-pollution - General.pdf
《CLC TS 50625-3-1-2015 Collection logistics & treatment requirements for WEEE - Part 3-1 Specification for de-pollution - General.pdf》由会员分享,可在线阅读,更多相关《CLC TS 50625-3-1-2015 Collection logistics & treatment requirements for WEEE - Part 3-1 Specification for de-pollution - General.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationCollection, logistics 29.100.01; 31.220.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 January 2015. Amendments/corrigenda issued
2、since publicationDate Text affectedPUBLISHED DOCUMENTPD CLC/TS 50625-3-1:2015TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CLC/TS 50625-3-1 January 2015 ICS 29.100.01; 13.030.99; 31.220.01 English Version Collection, logistics EN 50625-2-1, Collection, logistics CLC/TS 5062
3、5-3-1, Collection, logistics Mass balance methodology - establish a mass balance between incoming and outgoing streams; Analysis methodology - analyse representative samples from relevant fractions that result from the treatment of WEEE. NOTE In order to ensure that the target values and limit value
4、s remain state of the art it is planned to review, and where necessary revise, them with a frequency of approximately 3 years. When applying the methodologies to assess the de-pollution monitoring the sampling protocols shall be used (normative annex). 4.2 Target value methodology This methodology u
5、ses the following approach: establish targets: these masses per unit of input mass are obtained either by using the formula given in 6.2, 7.2, 8.2 and 10.2 or by using the values given in Table C.1 and Table C.2 of Annex C (which are based on the background of comparable studies developed in Europe
6、(see Bibliography); perform a batch process: determine the mass of the specified components removed by performing a batch process according to the methodology of Annex D of EN 50625-1:2014; evaluate the de-pollution performances: compare the results of the batch process with the specified target val
7、ues. As stated in B.2 of EN 50625-1:2014, to verify the efficiency of de-pollution during the performing of a batch process, corresponding target value(s) shall be reached. PD CLC/TS 50625-3-1:2015CLC/TS 50625-3-1:2015 (E) 8 4.3 Mass Balance methodology This methodology uses the following approach:
8、establish target values in terms of share of a pollutant in the output compared to the input of this pollutant (100 %); assess the quantity of a defined pollutant in the input of a batch and measure the quantity of that pollutant in the output fraction(s); evaluate the de-pollution performances by c
9、omparing the results of the batch process with the specified target values. As stated in 5.6 and B.1 of EN 50625-1:2014, to verify the efficiency of de-pollution for specific type of WEEE, e.g. temperature exchange equipment, a mass balance shall be performed and the corresponding target values shal
10、l be achieved. 4.4 Analysis methodology This methodology uses the following approach: establish the limits: these values are defined in this Technical Specification and are based on the background of comparable studies and legislation; sample the output fractions: the sample for the analysis shall b
11、e prepared according to the sampling procedure defined in this Technical Specification; evaluate the analysis results: the concentration of substances shall be determined according to the analysis procedure defined in this Technical Specification; evaluate the de-pollution performance: compare the r
12、esults of the analysis with the defined limit values. If the results of the analysis are below the limit values then the performance of de-pollution fulfils the requirements. As required by B.3 and B.4 of EN 50625-1:2014, the quality of de-pollution shall be measured by comparing the results of the
13、analysis with the corresponding limit values. The analysis establishes the amount of substances or substances that indicate the presence of items included in Annex F of EN 50625-1:2014 in the output fractions (if applicable to the treatment process). A laboratory shall perform the analysis on the sa
14、mples for the residual amount of PCB, cadmium and bromine. Depending on the treatment process used, one of the techniques below, as used in Annexes A and B, shall be used to obtain a representative mixed sample: sampling during a treatment process; post process sampling. NOTE 1 All the sampling prot
15、ocols are based on EN 14899. Analysis protocols will be implemented by laboratories. There are many types of physical-chemical analysis and this Technical Specification describes the suitable method for each type of sample. NOTE 2 In related standards and in chemical analysis processing a sample is
16、often called digestion of a sample. Chemical analysis including processing of the samples should be performed by a laboratory that complies with EN ISO/IEC 17025. If the laboratory does not comply with EN ISO/IEC 17025 then duplicate samples PD CLC/TS 50625-3-1:2015CLC/TS 50625-3-1:2015 (E) 9 shall
17、be sent for checking to laboratory that does meet EN ISO/IEC 17025 on a regular basis, according to a defined process. NOTE 3 The laboratory can be internal to the treatment operator or a third party laboratory. The preparation of the test portion of the sample to be analyzed shall be carried out ac
18、cording to EN 15002 and then: for cadmium, the digestion of the sample and the subsequent analysis shall be carried out by ICP-OES or ICP-MS according to EN 62321-5. As an alternative the digestion shall be carried out according to EN 13656 and the subsequent analysis performed according to EN ISO 1
19、1885 or the EN ISO 17294 series; for bromine, the digestion of the sample and the subsequent analysis shall be carried out in accordance with EN 14582; for PCB, the digestion (e.g. homogenization) of the sample and the subsequent analysis shall be carried out in accordance with EN 15308 or US EPA 80
20、82A/2007, quantification of PCBs as congeners. NOTE 4 ICP-OES is an abbreviation for Inductively Coupled Plasma/Optical Emission Spectrometry and ICP-MS is an abbreviation for Inductively Coupled Plasma Mass Spectrometry, which are the two methods of chemical analysis to be used when analyzing cadmi
21、um. PD CLC/TS 50625-3-1:2015CLC/TS 50625-3-1:2015 (E) 10 5 Overview of the applicable methodologies Applicable methodologies Table 1 identifies what methodology shall be used for every treatment process flow. The following components are those identified in Annex F of EN 50625-1:2014. Table 1 Applic
22、able methodologies Treatment process flowscCategories in Directive 2012/19/EU Target value methodology Mass Balance methodology Analysis methodology Large appliancesdAnnex I: cat. 1. Annex III: cat. 4. Applicable to capacitorse. Not applicable. Applicable for the PCB in the physically smallest non-m
23、etallic mechanical treatment fraction (see A.1). Cooling and freezing appliancesd fAnnex I: cat. 1. Annex III: cat. 1. Applicable to capacitorse. EN 50574 and future TSa. EN 50574 and future TSaCRT display appliancesdAnnex I: cat. 3 equipment for the generation of electric currents, etc.). cTreatmen
24、t flows are defined based on the common treatment flows. dIn case of different composition of the flow treated, adjustment shall be made to manage this different case. eSee A.2 of EN 50625-1:2014. fWhile Directive 2012/19/EU refers to the term Temperature Exchange Equipment this term includes radiat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTS50625312015COLLECTIONLOGISTICSTREATMENTREQUIREMENTSFORWEEEPART31SPECIFICATIONFORDEPOLLUTIONGENERALPDF

链接地址:http://www.mydoc123.com/p-629613.html