1、PUBLISHED DOCUMENTPD CEN/TR 15177:2006Testing the freeze-thaw resistance of concrete Internal structural damageICS 91.080.40g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g5
2、3g44g42g43g55g3g47g36g58PD CEN/TR 15177:2006This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 November 2006 BSI 2006ISBN 0 580 49652 XNational forewordThis Published Document was published by BSI. It is the UK implementation of CEN/TR 1517
3、7:2006.The UK participation in its preparation was entrusted by Technical Committee B/517, Concrete, to Subcommittee B/517/1, Concrete production and testing.A list of organizations represented on B/517/1 can be obtained on request to its secretary.This publication is a Published Document (PD) and i
4、s not to be regarded as a British Standard and therefore should be used for guidance only.The original document was proposed as a European standard but at the draft for public comment (DPC) stage the project status was changed to a CEN Report as it was not deemed suitable to be published as a Europe
5、an standard. The CEN Report was published so that research laboratories could evolve the test methods and gain some experience of the relevance of such tests to local materials. Therefore, the UK Committee B/517/1 has implemented CEN Report 15177:2006 as PD CEN/TR 15177:2006 but with the following c
6、omments.Whilst there are no performance values given in CEN/TR 15177, the originators of the tests have values they apply in practice and these are known to others. It is accepted that a concrete satisfying these values is likely to perform well in extreme freeze/thaw conditions. However, in the UK
7、there are many concretes that have been shown to perform adequately in the prevailing environmental conditions, but, if tested against these criteria, would fail by a substantial margin. BSI Technical Committee Working Group B/517/1/30 considers that these test methods would not normally be appropri
8、ate for evaluating the performance of concrete for UK conditions.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Amendments issued since publicationAmd. No. Date CommentsTECHNICAL REPORTRAPPORT TECHNIQUETECHNI
9、SCHER BERICHTCEN/TR 15177April 2006ICS 91.080.40English VersionTesting the freeze-thaw resistance of concrete - Internalstructural damagePrfung des Frost-Tauwiderstandes von Beton - InnereGefgestrungThis Technical Report was approved by CEN on 31 August 2005. It has been drawn up by the Technical Co
10、mmittee CEN/TC 51.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, S
11、pain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Me
12、mbers.Ref. No. CEN/TR 15177:2006: E2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .5 4 Equipment 6 5 Making of test specimens .9 6 Principle of measurement the internal structural damage10 7 Beam test11 8 Slab test 16 9 CIF-test24 Bibliography 34
13、 CEN/TR 15177:20063 Foreword This document (CEN/TR 15177:2006) has been prepared jointly by Technical Committee CEN/TC 51 “Cement and building limes“, the secretariat of which is held by IBN/BIN and by Technical Committee CEN/TC 104 “Concrete and related products“, the secretariat of which is held b
14、y DIN. No existing European Standard is superseded. It is based on the Austrian Standard NORM B 3303 “Testing of Concrete“ and on the RILEM recommendation “Test methods of frost resistance of concrete“ of RILEM TC 176 IDC. These tests have since been developed by individual countries. This document
15、takes into account those developments. CEN/TR 15177:20064 Introduction Concrete structures exposed to the effects of freezing and thawing need to be durable, to have an adequate resistance to this action and, in cases such as road construction, to freezing and thawing in the presence of de-icing age
16、nts. It is desirable, especially in the case of new constituents or new concrete compositions, to test for such properties. This also applies to concrete mixes, concrete products, precast concrete, concrete elements or concrete in situ. Many different test methods have been developed. No single test
17、 method can completely reproduce the conditions in the field in all individual cases. Nevertheless, any method should at least correlate to the practical situation and give consistent results. Such a test method may not be suitable for deciding whether the resistance is adequate in a specific instan
18、ce but will provide data of the resistance of the concrete to freeze-thaw-attack and freeze-thaw-attack in the presence of de-icing agents. If the concrete has inadequate resistance there are two types of concrete deterioration when a freeze-thaw attack occurs, internal structural damage and scaling
19、. The three test methods in this document describe the testing for internal structural damage. The scaling is dealt with in prCEN/TS 12390-9. This document contains three different test methods, which are well proved in different parts of Europe. Always they produce consistent results. For that reas
20、on no single test method can be established as reference test method. In the case that two laboratories will test the same concrete, they have to agree to only one test method with the same measurement procedure. The application of limiting values will require the establishment of the correlation be
21、tween laboratory results and field experience. Due to the nature of the freeze-thaw action, such correlation would have to be established in accordance with local conditions and still have to be done. CEN/TR 15177:20065 1 Scope This document specifies three test methods for the estimation of the fre
22、eze-thaw resistance of concrete with regard to internal structural damage. It can be used either to compare new constituents or new concrete compositions against a constituent or a concrete composition that is known to give adequate performance in the local environment or to assess the test results
23、against some absolute numerical values based on local experiences. Extrapolation of test results to assess different concrete i.e. new constituents or new concrete compositions requires an expert evaluation. NOTE Specification based on these test methods should take into account the behaviour of con
24、crete under practical conditions. There is no established correlation between the results obtained by the three test methods. All tests will clearly identify poor and good behaviour, but they differ in their assessment of marginal behaviour. 2 Normative references The following referenced documents
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR151772006TESTINGTHEFREEZETHAWRESISTANCEOFCONCRETEINTERNALSTRUCTURALDAMAGE 混凝土 耐冻露 性能 试验 内部结构 损坏

链接地址:http://www.mydoc123.com/p-592068.html