BS EN 14626-2012 Ambient air Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy《环境空气 用非色散红外线光谱法测量一氧化碳浓度的标准方法》.pdf
《BS EN 14626-2012 Ambient air Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy《环境空气 用非色散红外线光谱法测量一氧化碳浓度的标准方法》.pdf》由会员分享,可在线阅读,更多相关《BS EN 14626-2012 Ambient air Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy《环境空气 用非色散红外线光谱法测量一氧化碳浓度的标准方法》.pdf(88页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 14626:2012Ambient air Standardmethod for the measurementof the concentration of carbonmonoxide by non-dispersiveinfrared spectroscopyBS EN 14626:2012 BRITISH STANDARDNation
2、al forewordThis British Standard is the UK implementation of EN 14626:2012. Itsupersedes BS EN 14626:2005 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/3, Ambient atmospheres.A list of organizations represented on this committee can beobtained on
3、 request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 69300 7ICS 13.040.20Compliance with a Briti
4、sh Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2012.Amendments issued since publicationDate Text affectedBS EN 14626:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM E
5、N 14626 August 2012 ICS 13.040.20 Supersedes EN 14626:2005English Version Ambient air - Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy Air ambiant - Mthode normalise de mesurage de la concentration en monoxyde de carbone par spectr
6、oscopie rayonnement infrarouge non dispersif Luftqualitt - Messverfahren zur Bestimmung der Konzentration von Kohlenmonoxid mit nicht-dispersiver Infrarot-Photometrie This European Standard was approved by CEN on 10 May 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations
7、which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This
8、 European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN membe
9、rs are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portuga
10、l, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any
11、means reserved worldwide for CEN national Members. Ref. No. EN 14626:2012: EBS EN 14626:2012EN 14626:2012 (E) 2 Contents Contents 2Foreword 41 Scope 52 Normative references 63 Terms and definitions . 64 Abbreviated terms . 105 Principle 115.1 General 115.2 Measuring principle . 115.3 Type approval t
12、est . 115.4 Field operation and quality control 126 Sampling . 126.1 General 126.2 Sampling location 126.3 Sampling system . 126.4 Control and regulation of sample flow rate 136.5 Sampling pump for the manifold 147 Analyser equipment 147.1 General 147.2 Interferents . 147.3 Details about analyser eq
13、uipment . 147.4 Pressure measurement . 157.5 Flow rate indicator . 157.6 Sampling pump for the analyser 157.7 Particle filter . 158 Type approval of carbon monoxide analysers . 158.1 General 158.2 Relevant performance characteristics and performance criteria . 168.3 Design change . 188.4 Procedures
14、for determination of the performance characteristics during the laboratory test . 188.5 Determination of the performance characteristics during the field test 288.6 Expanded uncertainty calculation for type approval . 329 Field operation and ongoing quality control 339.1 General 339.2 Suitability ev
15、aluation . 33BS EN 14626:2012EN 14626:2012 (E) 3 9.3 Initial installation . 359.4 Ongoing quality assurance/quality control. 369.5 Calibration of the analyser 389.6 Checks 399.7 Maintenance . 439.8 Data handling and data reports 449.9 Measurement uncertainty . 4410 Expression of results 4511 Test re
16、ports and documentation 4511.1 Type approval test . 4511.2 Field operation . 46Annex A (normative) Test of lack of fit . 48Annex B (informative) Sampling equipment. 50Annex C (informative) Schematics of non-dispersive infrared spectrometer 52Annex D (informative) Manifold testing 54Annex E (normativ
17、e) Type approval 56Annex F (informative) Calculation of uncertainty in field operation at the 8-hour limit value 75Annex G (informative) Significant technical changes . 83Bibliography 84BS EN 14626:2012EN 14626:2012 (E) 4 Foreword This document (EN 14626:2012) has been prepared by Technical Committe
18、e CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2013, and conflicting national standards shall be withdrawn at the lat
19、est by February 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14626:2005. The technical changes ma
20、de since EN 14211:2005 are listed in Annex G of this European Standard. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denma
21、rk, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 14626:201
22、2EN 14626:2012 (E) 5 1 Scope This European Standard specifies a continuous measurement method for the determination of the concentration of carbon monoxide present in ambient air based on the non-dispersive infrared spectroscopic measuring principle. This standard describes the performance character
23、istics and sets the relevant minimum criteria required to select an appropriate non-dispersive infrared spectroscopic analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requiremen
24、ts as specified in Annex I of Directive 2008/50/EC 1 and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air up to 100 mg/m3carbon monoxide. This concentration range
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN146262012AMBIENTAIRSTANDARDMETHODFORTHEMEASUREMENTOFTHECONCENTRATIONOFCARBONMONOXIDEBYNONDISPERSIVEINFRAREDSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-572607.html