BS DD IEC TS 61094-7-2006 Measurement microphones - Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones《计量扩音器 实验室标准扩音器的自.pdf
《BS DD IEC TS 61094-7-2006 Measurement microphones - Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones《计量扩音器 实验室标准扩音器的自.pdf》由会员分享,可在线阅读,更多相关《BS DD IEC TS 61094-7-2006 Measurement microphones - Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones《计量扩音器 实验室标准扩音器的自.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58between free-field and pressure sensitivity levels of laboratory standard microphonesICS 17.140.50M
2、easurement microphones Part 7: Values for the difference DRAFT FOR DEVELOPMENTDD IEC/TS 61094-7:2006DD IEC/TS 61094-7:2006This Draft for Development was published under the authority of the Standards Policy and Strategy Committee on 31 July 2006 BSI 2006ISBN 0 580 48976 0comments will be welcomed. T
3、hese should be sent to the Secretary of BSI Technical Committee EPL/29, Electroacoustics, at British Standards House, 389 Chiswick High Road, London W4 4AL, giving the document reference and clause number and proposing, where possible, an appropriate revision of the text.A list of organizations repr
4、esented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”,
5、 or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Summary of pagesThis document comprises a front cover, an insid
6、e front cover, the IEC/TS title page, pages 2 to 9 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsA review of this Draft for Development will be carried out not later than 2 yea
7、rs after its publication.Notification of the start of the review period, with a request for the submission of comments from users of this Draft for Development, will be made in an announcement in the appropriate issue of Update Standards. According to the replies received, the responsible BSI Commit
8、tee will judge whether the Draft for Development can be converted into a British Standard or what other action should be taken.Observations which it is felt should receive attention before the official call for National forewordThis Draft for Development reproduces verbatim IEC/TS 61094-7:2006. It s
9、upersedes BS 5941:1980 which is withdrawn.This publication is not to be regarded as a British Standard.It is being issued in the Draft for Development series of publications and is of a provisional nature. It should be applied on this provisional basis, so that information and experience of its prac
10、tical application can be obtained.IECTECHNICAL SPECIFICATION TS 61094-7First edition2006-05Measurement microphones Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones Reference number CEI/IEC/TS 61094-7:2006 DD IEC/TS 61094-7:2006 2
11、 CONTENTS 1 Scope 3 2 Normative references .3 3 Terms and definitions .3 4 Reference environmental conditions3 5 Background 4 6 Difference values of free-field and pressure sensitivity levels.4 6.1 General .4 6.2 Data sources .4 6.3 Expression for the difference between free-field and pressure sensi
12、tivity levels 4 6.4 Uncertainty on the calculated free-field sensitivity level 5 Annex A (informative) Source data .7 Annex B (informative) Acknowledgements 8 Annex C (informative) Historical data .9 DD IEC/TS 61094-7:2006 3 MEASUREMENT MICROPHONES Part 7: Values for the difference between free-fiel
13、d and pressure sensitivity levels of laboratory standard microphones 1 Scope This part of IEC 61094 gives a polynomial function derived from a least square fit to data from several laboratories, for the differences between free-field and pressure sensitivity levels of laboratory standard microphones
14、 as specified in IEC 61094-1, enables determination of the free-field sensitivity level of a laboratory standard microphone for zero-degrees incidence in air by adding values of these differences to the pressure sensitivity level, gives tabulated values for the polynomial function for a range of fre
15、quency and temperature, is applicable when a suitable free-field calibration is not available. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest ed
16、ition of the referenced document (including any amendments) applies. IEC 61094-1, Measurement Microphones Part 1: Specifications for laboratory standard microphones IEC 61094-2:1992, Measurement Microphones Part 2: Primary method for pressure calibration of laboratory standard microphones by the rec
17、iprocity technique IEC 61094-3:1995, Measurement Microphones Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique 3 Terms and definitions For the purpose of this part of IEC 61094, the following definition applies in addition to the defini
18、tions given in IEC 61094-1, IEC 61094-2:1992 and IEC 61094-3:1995. 3.1 zero-degrees incidence for a frontal incident sound wave, direction perpendicular to the diaphragm of the microphone 4 Reference environmental conditions The reference environmental conditions are: temperature 23,0 C static press
19、ure 101,325 kPa relative humidity 50 % DD IEC/TS 61094-7:2006 4 5 Background According to the definitions of the free-field and pressure sensitivities of a microphone, the two sensitivities will differ from each other for the following reasons: owing to diffraction and reflection, the introduction o
20、f a microphone into a free progressive sound wave disturbs the sound field. Thus the sound pressure at the microphone diaphragm is not the same as that of the undisturbed free field, owing to diffraction and reflection the sound pressure over the diaphragm of the microphone is not uniform and, for a
21、 specific microphone, is affected by the acoustic impedance of its diaphragm. The values given have been derived from theoretical considerations combined with measurements of the pressure and free-field sensitivity levels of a number of microphones carried out in accordance with IEC 61094-2 and IEC
22、61094-3, respectively, to which reference should be made concerning terminology, microphone preamplifier configurations, etc. 6 Difference values of free-field and pressure sensitivity levels 6.1 General The difference between free-field and pressure sensitivity is determined by two factors, see 5.4
23、 of IEC 61094-3:1995. The major part is determined by the geometrical diffraction around the microphone and its support. This is a wavelength phenomenon and thus a function of temperature. A minor part is determined by the interaction between the impedance of the microphone diaphragm and its radiati
24、on impedance. As the radiation impedance depends on the static pressure and temperature this part will be a function of both these variables. Although this part also depends on the individual microphone impedance, the variations between microphones of the same model can be neglected in comparison wi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDIECTS6109472006MEASUREMENTMICROPHONESVALUESFORTHEDIFFERENCEBETWEENFREEFIELDANDPRESSURESENSITIVITYLEVELSOFLABORATORYSTANDARDMICROPHONES

链接地址:http://www.mydoc123.com/p-548319.html