BS 8591-2014 Remote centres receiving signals from alarm systems Code of practice《接收警报系统信号的远程中心 实用规程》.pdf
《BS 8591-2014 Remote centres receiving signals from alarm systems Code of practice《接收警报系统信号的远程中心 实用规程》.pdf》由会员分享,可在线阅读,更多相关《BS 8591-2014 Remote centres receiving signals from alarm systems Code of practice《接收警报系统信号的远程中心 实用规程》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS 8591:2014Remote centres receivingsignals from alarm systems Code of practicePublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2014Published by BSI Standards
2、 Limited 2014ISBN 978 0 580 83675 6ICS 13.320The following BSI references relate to the work on this document:Committee reference GW/1/11Draft for comment 13/30286749 DCPublication historyFirst published April 2014Amendments issued since publicationDate Text affectedBS 8591:2014 BRITISH STANDARDCont
3、entsForeword ii1 Scope 12 Normative references 13 Terms, definitions and abbreviations 24 Planning 65 Construction and facilities 76 Operation of an alarm receiving centre 147 Records 228 Contingency plan 23AnnexesAnnex A (informative) Security and technical implications of remote access toremote ce
4、ntre data systems 25Annex B (informative) Representation of the typical relationship andcommunication paths between stakeholders in alarm monitoring andresponse 27Annex C (informative) Filtering actions for fire alarm signals 28Annex D (informative) Example form of agreement for authorizing alarmrec
5、eiving centre to exercise discretion regarding the filtering out of alarminformation 30Bibliography 32List of figuresFigure B.1 Typical relationship and communication paths between stakeholdersin alarm monitoring and response 27Figure C.1 Fire response from ARC to site following receipt of a fire al
6、armsignal 28Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv,pages 1 to 34, an inside back cover and a back cover.BRITISH STANDARD BS 8591:2014 The British Standards Institution 2014 iForewordPublishing informationThis British Standard is published by BSI S
7、tandards Limited, under licence fromThe British Standards Institution, and came into effect on 30 April 2014. It wasprepared by Subcommittee GW/1/11, Remote Centres, under the authority ofTechnical Committee GW/1, Electronic security systems. A list of organizationsrepresented on this committee can
8、be obtained on request to its secretary.SupersessionTogether with BS EN 50518-1:2010, BS EN 50518-2:2010 andBS EN 50518-3:20111), this British Standard supersedes BS 5979:2007, which iswithdrawn.Relationship with other publicationsThis British Standard has been produced following the publication of
9、theBS EN 50518 series of standards, which apply to alarm signals generated fromintruder and hold-up alarm systems (Ib) by not more than six residents living together as a single household,including a household where care is provided for residents;c) by persons who do not live together as a family, b
10、ut who live inself-contained single-family flats, maisonettes or bedsits within the unit; ord) as a shared houseNOTE The definitions in c) and d) relate only to some types of house in multipleoccupation and specifically exclude hostel type accommodation, for whichBS 5839-1 is more appropriate. They
11、can, however, include houses with long-termlodgers.3.1.12 false alertsignalled alarm condition that (without having been extended to the relevantemergency service) is regarded by the ARC as cancelled, such cancellation havingbeen authorized by the customerNOTE 1 Such authorization can be either:a) o
12、n a case-by-case basis by use of suitable code words or numbers inaccordance with a defined alarm filtering routine; orb) by prior written agreement.NOTE 2 Communication whereby the customer/user causes (i) a mis-operation signalor (ii) an unset signal to be sent to the ARC affirming that the signal
13、led alarmcondition is to be filtered out and not extended to the relevant emergency serviceare examples of cancellation authorized by the customer see NOTE 1a).NOTE 3 “False alerts” are not regarded as “false alarms”. False alarms are eventsthat have not been successfully identified and filtered out
14、, and have therefore beennotified to the relevant emergency service.3.1.13 fire alarm filteringagreed procedure between the ARC and responsible or authorised person (user)at the premises whereby signalled fire alarm conditions are confirmed orcancelled as fire signalsNOTE Such filtering is not appli
15、ed to signals from fire alarm systems in residentialcare premises.3.1.14 fire resistanceability of an element of building construction, component or structure to fulfil,for a stated period of time, the required stability, fire integrity and/or thermalinsulation and/or other expected duty in a standa
16、rd fire resistance testNOTE The designation “fire resisting” given to an element implies that thiselement fulfils the requirements of the relevant standard fire test.3.1.15 fire signalsignal intended to indicate the occurrence of a fireSOURCE: BS 5839-1:2013, 3.253.1.16 hold up devicedevice which, w
17、hen manually operated, causes an alarm signal or message to begeneratedBRITISH STANDARD BS 8591:2014 The British Standards Institution 2014 3SOURCE: BS EN 50518-1:2010, 3.1.93.1.17 mis-operation signalsignal that is definitely and unambiguously identifiable at the ARC as indicatingto the ARC that th
18、e alarm system has mis-operated and therefore that the alarmsignal is to be filtered out and not extended to the relevant emergency serviceNOTE The designation of a particular type of signal as a mis-operation signal istherefore a matter for agreement between the alarm company and ARC, with theconcu
19、rrence of the customer.3.1.18 operations areathat part of an ARC concerned directly with the display of information from thealarm systems monitored by the ARC3.1.19 police responseemergency police response as defined in the ACPO and Police Scotland policiesdependent upon the type of alarm system ins
20、talled3.1.20 remote accessrestricted facility to view/edit data and/or to create new records from outsidethe shell of the remote centre3.1.21 remote centrelocation remote from the supervised premises, in which the informationconcerned with the state of one or more alarm systems is collected either f
21、orreporting (i.e. an ARC or a satellite) or for onward transmissionNOTE For the avoidance of doubt, an ATS monitoring centre as defined inBS EN 50136-1 does not come within the definition of remote centre for the purposeof this British Standard.3.1.22 residential care homehome which provides accommo
22、dation and includes nursing care, personal careor personal support, to vulnerable children or adults, but excluding hospitals,schools and sheltered housingNOTE Such premises include homes for: older people; children and young people; people with learning disabilities; people with drug and alcohol pr
23、oblems; people with mental health problems; people with physical and sensory impairment; and respite and short breaks.3.1.23 response agreementset of instructions agreed between the remote centre and the client as to theactions to be taken in the event of an alarm signal being received3.1.24 satelli
24、teremote centre, normally unmanned, in which the information concerning thestate of alarm and/or CCTV systems is collected and processed for onwardtransmission either direct or via a further satellite to an ARCNOTE 1 The junction point of a number of alarm system signalling circuits is notregarded a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS85912014REMOTECENTRESRECEIVINGSIGNALSFROMALARMSYSTEMSCODEOFPRACTICE 接收 警报 系统 信号 远程 中心 实用 规程 PDF

链接地址:http://www.mydoc123.com/p-547519.html