《BS 7951-2000 Electricity meters - Alternating-current single-phase static watt-hour telemeters of accuracy class 1 or 2《电表 精确级为1或2的交流单相静态瓦时遥测计》.pdf》由会员分享,可在线阅读,更多相关《BS 7951-2000 Electricity meters - Alternating-current single-phase static watt-hour telemeters of accuracy class 1 or 2《电表 精确级为1或2的交流单相静态瓦时遥测计》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 7951:2000 ICS 17.220.2
2、0 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Specification for Electricity meters Alternating-current single-phase static watt-hour telemeters of accuracy class 1 or 2This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee,
3、 was published under the authority of the Standards Committee and comes into effect on 15 May 2000 BSI 05-2000 The following BSI references relate to the work on this standard: Committee reference PEL/13 Draft for comment 96/210564 DC ISBN 0 580 33159 8 BS 7951:2000 Amendments issued since publicati
4、on Amd. No. Date Comments Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee PEL/13, Electricity meters, upon which the following bodies were represented: BCEMA BEAMA Metering Association (BMA) Electricity Association Electr
5、icity Pool of England and Wales Energy Systems Trade Association Flag Association Institution of Electrical Engineers Office of Electricity Regulation (OFFER) Co-opted membersBS 7951:2000 BSI 05-2000 i Contents Page Committees responsible Inside front cover Foreword ii Introduction 1 1 Scope 1 2 Nor
6、mative references 1 3 Terms and definitions 1 4 Requirements 1 4.1 Rated electrical values 1 4.2 Mechanical requirements 2 4.3 Ambient conditions 3 4.4 Electrical requirements 3 4.5 Electromagnetic compatibility (EMC) 4 4.6 Accuracy 4 4.7 Radio teleswitch module 4 4.8 Other requirements 5 5 Tests 5
7、5.1 General 5 5.2 Interaction affecting accuracy 5 5.3 Interaction causing emission of spurious pulses 5ii BSI 05-2000 BS 7951:2000 Foreword This British Standard has been prepared by Technical Committee PEL/13. As far as possible, the clause numbering of this standard has been structured to corresp
8、ond with that of BS EN 61036:1997. SI units in accordance with the relevant parts of BS 5775:1993 are used throughout this standard. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Co
9、mpliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 5 and a back cover. The BSI copyright notice displayed in this document indicates when the document wa
10、s last issued. BSI 05-2000 1 BS 7951:2000 Introduction BS 7647 describes a radio-controlled switch (radio teleswitch) which is used with an electricity meter to provide facilities for implementing a multiple-rate tariff. Technological development now allows the functions of a radio teleswitch to be
11、integrated within a static electricity meter as specified in BS EN 61036. This obviates the need for two separate devices. Such an integrated device is known as a (radio) telemeter. A telemeter may incorporate output switches and local communications facilities via an optical port, and is intended f
12、or use in those locations in domestic, industrial or commercial premises where it is custom and practice to install electricity meters, and tariff and load control devices. The telemeter has energy registers associated with each metrological element for the registration of controlled and/or uncontro
13、lled energy usage. Timing for effect of such registers is provided by an internal clock, synchronized from time signals decoded by the radio teleswitch module. 1 Scope This British Standard specifies requirements for alternating-current single-phase static watt-hour telemeters of accuracy class 1 or
14、 class 2, with one or two measuring elements. It applies to telemeters of protective class I or class II. NOTE Accuracy classes and protective classes are as applied in BS EN 61036:1997. 2 Normative references The following normative documents contain provisions which, through reference in this text
15、, constitute provisions of this British Standard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. For undated references, the latest edition of the publication referred to applies. BS 7647:1993, Specification for radio teleswitches for tariff
16、and load control. BS 7856:1996, Code of practice for design of alternating current, watt-hour meters for active energy (classes 1 and 2). BS EN 55022:1995, Limits and methods of measurement of radio disturbance characteristics of information technology equipment. BS EN 60068-2-6:1996, Environmental
17、testing Test methods Test Fc Vibration (sinusoidal). BS EN 60068-2-27:1993, Environmental testing Test methods Environmental testing procedures Tests Test Ea and guidance Shock. BS EN 60529:1992, Degrees of protection provided by enclosures (IP code). BS EN 61036:1997, Alternating current static wat
18、t-hour meters for active energy (classes 1 and 2). BS EN 61107:1996, Data exchange for meter reading, tariff and load control Direct local data exchange. 3 Terms and definitions For the purposes of this British Standard, the following terms and definitions apply, together with relevant definitions g
19、iven in BS 7647:1993 and BS EN 61036:1997. 3.1 telemeter electricity meter incorporating a radio teleswitch module for tariff and load control 3.2 radio teleswitch module part of the telemeter which receives and decodes the radio teleswitch signals and transmits appropriate information to its output
20、 circuits 3.3 local communication port infra-red input/output communications facility as specified in BS EN 61107:1996 3.4 output switch switch controlled by information from the radio teleswitch module NOTE Output switches include physical switches, with outputs accessible externally, and internal
21、logic switches, which set parameters such as tariff rate within the telemeter. 3.5 load switch physical output switch for controlling space-heating and/or water-heating equipment 3.6 auxiliary switch physical output switch for signalling changes of rate to external equipment 4 Requirements 4.1 Rated
22、 electrical values 4.1.1 Rated voltage (U n ) The telemeter shall be rated for a nominal supply voltage of 230 V. 4.1.2 Rated current Measuring elements shall be rated at 20 A basic (I b ) and 100 A maximum (I max ). NOTE The total current which a two-element telemeter passes will not in practice ex
23、ceed 120 A, irrespective of the sum of the I max rating of each measuring element. This is because the meter will be controlled by a suppliers fuse rated at up to 100 A, which will operate to break the circuit at about this level, depending on the fusing factor. 4.1.3 Standard frequency The telemete
24、r shall be suitable for a standard supply frequency of 50 Hz.2 BSI 05-2000 BS 7951:2000 4.2 Mechanical requirements 4.2.1 General The telemeter shall conform to BS EN 61036:1997, 4.2.1. 4.2.2 Case The telemeter shall conform to BS EN 61036:1997, 4.2.2. 4.2.3 Window If the cover is not transparent, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS79512000ELECTRICITYMETERSALTERNATINGCURRENTSINGLEPHASESTATICWATTHOURTELEMETERSOFACCURACYCLASS1OR2 电表

链接地址:http://www.mydoc123.com/p-547190.html