BS 6883-1999 Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《 船舶和活动式与固定式近海设备中固定布线用的弹性绝缘电缆 要求和试验方法》.pdf
《BS 6883-1999 Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《 船舶和活动式与固定式近海设备中固定布线用的弹性绝缘电缆 要求和试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS 6883-1999 Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units - Requirements and test methods《 船舶和活动式与固定式近海设备中固定布线用的弹性绝缘电缆 要求和试验方法》.pdf(70页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 6883:1999 ICS 47.020.6
2、0 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units Requirements and test methodsThis British Standard, having been prepared under the direction of the Electrotechnical Sector Committee,
3、was published under the authority of the Standards Committee and comes into effect on 15 June 1999 BSI 06-1999 First published as BS 883 April 1940 Second edition November 1949 Third edition January 1958 Fourth edition December 1967 First edition as BS 6883 January 1969 Second edition June 1991 Thir
4、d edition June 1999 The following BSI references relate to the work on this standard: Committee reference GEL/20/6 Draft for comment 96/214276 DC ISBN 0 580 33002 8 BS 6883:1999 Amendments issued since publication Amd. No. Date Comments Committees responsible for this British Standard The preparatio
5、n of this British Standard was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/6, Ships cables, upon which the following bodies were represented: British Cable Makers Confederation Institute of Marine Engineers Lloyds Register of Shipping Ministry of Defence UK Offsh
6、ore Operators Association LimitedBS 6883:1999 BSI 06-1999 i Contents Page Committees responsible Inside front cover Foreword iv 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Designation of cables 2 5 General requirements 3 6 Cables 150/250 V (pairs, triples and quads) 5 7 Single-cor
7、e and multicore cables 600/1 000 V, 1 900/3 300 V and 3 300/3 300 V 7 8 Single-core and three-core (non-radial field) cables 3 800/6 600 V, 6 600/6 600 V and 6 350/11 000 V 28 9 Single-core and three-core (radial field) cables 3 800/6 600 V, 6 350/11 000 V and 8 700/15 000 V 34 Annex A (informative)
8、 Recommendations for the selection of cables, and information on cable operating temperatures 45 Annex B (informative) Recommendations for the installation of cables 46 Annex C (normative) Measurement of thickness 47 Annex D (normative) Insulation screen strippability test 47 Annex E (normative) Met
9、hod of measuring resistivity of extruded semi-conducting conductor and insulation screens 47 Annex F (normative) Partial discharge test 50 Annex G (normative) Bending test 51 Annex H (normative) Power factor test in relation to temperature 51 Annex J (normative) Heating cycle test 51 Annex K (normat
10、ive) Impulse voltage test 51 Annex L (normative) Test for adherence of screens at short circuit temperature 52 Annex M (normative) Voltage test 53 Annex N (normative) Insulation resistance tests 53 Annex P (normative) Method of measuring the surface resistivity of semi-conducting tape 55 Annex Q (no
11、rmative) Compatibility test 56 Annex R (informative) Guidance on type tests 56 Annex S (informative) Guide to use 58 Bibliography 63 Figure E.1 Test piece and arrangement of electrodes for measurement of resistivity of conductor screen 48 Figure E.2 Test piece and arrangement of electrodes for measu
12、rement of resistivity of insulation screen 49 Figure P .1 Method of measuring the surface resistivity of semi-conducting tape 55 Table 1 Diameter of braiding wires 3 Table 2 List of tests applicable to the cables specified in clause 6 7 Table 3 Schedule of tests 8 Table 4 Compatibility requirements
13、9 Table 5 Elastomer insulated, individually screened pairs, sheathed 150/250 V 9 Table 6 Elastomer insulated, collectively screened pairs, sheathed 150/250 V 9 Table 7 Elastomer insulated, individually screened pairs, sheathed, steel or bronze wire braided, sheathed 150/250 V 10BS 6883:1999 ii BSI 0
14、6-1999 Page Table 8 Elastomer insulated, collectively screened pairs, sheathed, steel or bronze wire braided, sheathed 150/250 V 10 Table 9 Elastomer insulated, individually screened triples, sheathed 150/250 V 11 Table 10 Elastomer insulated, collectively screened triples, sheathed 150/250 V 11 Tab
15、le 11 Elastomer insulated, individually screened triples, sheathed, steel or bronze wire braided, sheathed 150/250 V 11 Table 12 Elastomer insulated, collectively screened triples, sheathed, steel or bronze wire braided, sheathed 150/250 V 12 Table 13 Elastomer insulated, individually screened quads
16、 sheathed 150/250 V 12 Table 14 Elastomer insulated, individually screened quads, sheathed, steel or bronze wire braided, sheathed 150/250 V 12 Table 15 List of tests applicable to the cables specified in clause 7 15 Table 16 Schedule of tests 16 Table 17 Compatibility requirements 16 Table 18 Elast
17、omer insulated, sheathed, single-core, two-core, three-core and four-core cables 600/1 000 V 17 Table 19 Elastomer insulated, sheathed, 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 18 Table 20 Elastomer insulated, sheathed, bronze wire braided, sheathed, single-core cables 600/1 000 V 18 Table 21
18、 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, two-core cables 600/1 000 V 19 Table 22 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, three-core cables 600/1 000 V 20 Table 23 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, four
19、-core cables 600/1 000 V 21 Table 24 Elastomer insulated, sheathed, steel or bronze wire braided, sheathed, 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 21 Table 25 Elastomer insulated, sheathed, copper wire braided, sheathed, single-core cables 600/1 000 V 22 Table 26 Elastomer insulated, sheath
20、ed, copper wire braided, sheathed, two-core cables 600/1 000 V 23 Table 27 Elastomer insulated, sheathed, copper wire braided, sheathed, three-core cables 600/1 000 V 24 Table 28 Elastomer insulated, sheathed, copper wire braided, sheathed, four-core cables 600/1 000 V 25 Table 29 Elastomer insulate
21、d and sheathed, copper wire braided, sheathed, 5, 7, 12, 19, 27 and 37-core cables 600/1 000 V 25 Table 30 Elastomer insulated and sheathed, bronze wire braided, sheathed, single-core cables 1 900/3 300 V 26 Table 31 Elastomer insulated and sheathed, steel or bronze wire braided, sheathed, three-cor
22、e cables 1 900/3 300 V 26 Table 32 Elastomer insulated and sheathed, bronze wire braided, sheathed, single-core cables 3 300/3 300 V 27 Table 33 Elastomer insulated and sheathed, steel or bronze wire braided, sheathed, three-core cables 3 300/3 300 V 27 Table 34 List of tests applicable to the cable
23、s specified in clause 8 30 Table 35 Schedule of tests 30 Table 36 Compatibility requirements 31 Table 37 Elastomer insulated (non-radial field) and sheathed, bronze wire braided, sheathed single-core cables 3 800/6 600 V 31 BSI 06-1999 iii BS 6883:1999 Page Table 38 Elastomer insulated (non-radial f
24、ield) and sheathed, steel or bronze wire braided, sheathed, three-core cables 3 800/6 600 V 32 Table 39 Elastomer insulated (non-radial field) and sheathed, bronze wire braided, sheathed, single-core cables 6 600/6 600 V 32 Table 40 Elastomer insulated (non-radial field) and sheathed, steel or bronz
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS68831999ELASTOMERINSULATEDCABLESFORFIXEDWIRINGINSHIPSANDONMOBILEANDFIXEDOFFSHOREUNITSREQUIREMENTSANDTESTMETHODS

链接地址:http://www.mydoc123.com/p-546341.html