BS 4737-4 3-1988 Intruder alarm systems in buildings - Codes of practice - Code of practice for exterior alarm systems《建筑物擅入者报警系统 第4部分 惯例 第3节 外部报警系统》.pdf
《BS 4737-4 3-1988 Intruder alarm systems in buildings - Codes of practice - Code of practice for exterior alarm systems《建筑物擅入者报警系统 第4部分 惯例 第3节 外部报警系统》.pdf》由会员分享,可在线阅读,更多相关《BS 4737-4 3-1988 Intruder alarm systems in buildings - Codes of practice - Code of practice for exterior alarm systems《建筑物擅入者报警系统 第4部分 惯例 第3节 外部报警系统》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4737-4.3: 1988 Intruder alarm systems Part 4: Codes of practice Section 4.3 Code of practice for exterior alarm systems UDC 696.6:654.924.3:006.76:(083.71):005.002.5BS4737-4.3:1988 This British Standard, having been prepared under the direction of the Furniture and Household Equi
2、pment Standards Policy Committee, was published under the authority of the Board of BSI and comes into effect on 30December1988. BSI 12-1998 The following BSI references relate to the work on this standard: Committee reference FHM/45 Draft for comment 88/36848 DC ISBN 0 580 17040 3 Committees respon
3、sible for this British Standard The preparation of this British Standard was entrusted by the Furniture and Household Equipment Standards Policy Committee (FHM/) to Technical Committee FHM/45, upon which the following bodies were represented: Association for Payment Clearing Services Association of
4、Burglary Insurance Surveyors Association of Chief Police Officers of England and Wales Association of Metropolitan Authorities British Retailers Association British Security Industry Association British Telecommunications plc Construction Security Advisory Service Consumer Policy Committee of BSI De
5、partment of the Environment (Property Services Agency) Electrical Contractors Association Electrical Contractors Association of Scotland Electrical installation Equipment Manufacturers Association (BEAMA Ltd.) Electricity Supply Industry in England and Wales Electronic Engineering Association Home O
6、ffice Home Office Crime Prevention Centre Independent Associated Alarm Installers Ltd. Institution of Electrical and Electronics Incorporated Engineers Lloyds Syndicates Survey Department Loss Prevention Council Metropolitan Police Ministry of Defence National Association of Goldsmiths of Great Brit
7、ain and Ireland National Supervisory Council for Intruder Alarms Post Office Royal Institute of British Architects Telecommunication Engineering and Manufacturing Association Tobacco Advisory Council Wine and Spirit Security Liaison Ltd. Amendments issued since publication Amd. No. Date of issue Com
8、mentsBS4737-4.3:1988 BSI 12-1998 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Planning 1 4 Equipment 1 5 Installation 3 6 Commissioning and handover 6 Publications referred to Inside back coverBS4737-4.3:1988 ii BSI 12-1998 Foreword This Section o
9、f BS4737 has been prepared under the direction of the Furniture and Household Equipment Standards Policy Committee to provide recommendations for those intruder alarm systems in which a majority of the components of an installed system are sited in exposed or open areas or in the surroundings of a b
10、uilding. The systems considered are those providing security comparable to BS4737-1. Notwithstanding its title and scope, many of the basic requirements of BS4737-1 are applicable to exterior systems and, where relevant, are referred to in this document. The main objectives of BS4737 are to maximize
11、 the effectiveness of intruder alarm systems, in respect of the detection and signalling of unauthorized intrusions, and to minimize the incidence of false alarms. BS4737 is being revised and published in Parts as follows. Part 1: Specification for installed systems with local audible and/or remote
12、signalling; Part 2: Specification for installed systems for deliberate operation; Part 3: Specification for components (incorporating a revision of the existing; Sections3.1 to 3.14 of BS4737). Part 4: Codes of practice; Section 4.1: Code of practice for planning and installation; Section 4.2: Code
13、of practice for maintenance and records; Section 4.3: Code of practice for exterior alarm systems. Part 5: Terms and symbols; Section 5.1: Glossary of terms; Section 5.2: Recommendations for symbols for diagrams. BS4737 does not give any requirements for the degree of protection and a prospective cu
14、stomer should give careful consideration to the extent and degree of protection required, having regard to the nature of the site to be protected, the value of its contents and the prevailing circumstances. It should be recognized that comprehensive protection necessarily entails substantial expense
15、, but no intruder alarm system can possibly detect all forms of unauthorized entry or be completely tamper-proof. The successful operation of an installed intruder alarm system requires the active cooperation of the customer in carrying out the necessary procedures carefully and thoroughly. The usef
16、ulness of the whole system and its social acceptability can be jeopardized by lack of care. This care has to extend to the security both of keys and of information regarding the system, its design, installation and method of operation and to ensuring adequate maintenance, to preserve the protection
17、against criminal activity and to reduce the incidence of false alarms. In particular, a high level of site discipline and maintenance is considered to be a vital aspect in the minimizing of false alarms from exterior alarm systems. A British Standard does not purport to include all the necessary pro
18、visions of a contract. Users of British Standards are responsible for their correct application.BS4737-4.3:1988 BSI 12-1998 iii Compliance with a British Standard does not of itself confer immunity from legal obligations. In particular, systems utilizing electromagnetic radiation for detection or tr
19、ansmission may require approval by the Department of Trade and Industry (Radiocommunications Division), and the requirements of police force policies with respect to exterior intruder alarm system installations may differ significantly from those for systems installed in premises. Summary of pages T
20、his document comprises a front cover, an inside front cover, pages i to iv, pages1to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.iv blank
21、BS4737-4.3:1988 BSI 12-1998 1 1 Scope This Section of BS4737 gives recommendations for the planning, equipment and installation of intruder alarm systems in situations where the balance of the system is located exterior to any premises. The recommendations given in this code of practice cover all sy
22、stems from the basic to the most complex and all recommendations appropriate to a particular installation are applicable. NOTEThe titles of the publications referred to in this Section of BS4737 are listed on the inside back cover. 2 Definitions For the purposes of this Section of BS4737, the defini
23、tions given in BS4737-1 apply, together with the following. 2.1 exterior alarm system an intruder alarm system providing protection principally to open areas or to the surroundings of a building NOTETypically, these systems are used to protect such areas as vehicle compounds, container depots, build
24、ing sites and perimeter areas. 2.2 protected site the area to which protection is afforded by an exterior alarm system 3 Planning 3.1 General The planning of an exterior alarm system should follow the recommendations given in clause3 of BS4737-4.1:1987, wherever these are relevant. 3.2 Environment T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS4737431988INTRUDERALARMSYSTEMSINBUILDINGSCODESOFPRACTICECODEOFPRACTICEFOREXTERIORALARMSYSTEMS 建筑物 擅入

链接地址:http://www.mydoc123.com/p-544630.html