BS 3762-3 7-1986 Analysis of formulated detergents - Quantitative test methods - Method for determination of total non-ionic matter content《配制洗涤剂的分析 定量试验方法 非离子物质总含量的测定方法》.pdf
《BS 3762-3 7-1986 Analysis of formulated detergents - Quantitative test methods - Method for determination of total non-ionic matter content《配制洗涤剂的分析 定量试验方法 非离子物质总含量的测定方法》.pdf》由会员分享,可在线阅读,更多相关《BS 3762-3 7-1986 Analysis of formulated detergents - Quantitative test methods - Method for determination of total non-ionic matter content《配制洗涤剂的分析 定量试验方法 非离子物质总含量的测定方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED MAY1996 BS3762-3.7: 1986 Analysis of formulated detergents Part3: Quantitative test methods Section3.7 Method for determination of total non-ionic matter content NOTEIt is recommended that this Section be read in conjunction with the information in the “General Introductio
2、n”, published separately as BS3762-0. UDC 661.185:543BS3762-3.7:1986 This British Standard, having been prepared under the directionof the Chemicals Standards Committee, was published under the authority ofthe Board of BSI and comes intoeffect on 30 September1986 BSI 10-1999 The committees responsib
3、le for this British Standard are shown inPart0 The following BSI references relate to the work on this standard: Committee reference CIC/34 Draft for comment 85/52541 DC ISBN 0 580 15326 6 Foreword This Section of BS3762 has been prepared under the direction of the Chemicals Standards Committee and
4、supersedes method C1 of BS3762:1964 in so far as it applies to formulated detergents, but that method will continue to exist until a British Standard for the determination in surface active agents(raw materials) has been published. This standard describes a method of test only and should not be refe
5、rred to as a specification defining limits of purity. Reference to the standard should indicate that the method of test used is in conformity with BS3762-3.7. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for the
6、ir correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 and2, an inside back cover and a back cover. This standard has been updated (see c
7、opyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS3762-3.7:1986 BSI 10-1999 i Contents Page Foreword Inside front cover 1 Scope 1 2 Principle 1 3 Reage
8、nts 1 4 Apparatus 1 5 Procedure 1 6 Expression of results 2 7 Precision 2 8 Test report 2 Publications referred to Inside back coverii blankBS3762-3.7:1986 BSI 10-1999 1 1 Scope This Section of BS3762 describes a gravimetric method for the determination of the total non-ionic matter content of deter
9、gent products. NOTEThe titles of the publications referred to in this Section are listed on the inside back cover. 2 Principle A suitable aliquot portion is taken from the ethanol soluble portion(seeBS3762-3.5). The solution is stirred with a mixed bed of cation and anion exchange resins to remove i
10、onic active matter. The solution is then filtered and evaporated, and the non-ionic matter is determined gravimetrically. This extract will include non-detergent organic matter and also any alkanolamide-type lather improver if present. 3 Reagents The reagents shall be of a recognized analytical reag
11、ent grade. Water complying with BS3978 shall be used throughout. 3.1 Ethanol NOTEFor the purposes of3.1, the ethanol may be replaced by industrial methylated spirits complying with BS3591, or such spirits diluted as required. It should be noted that the use of industrial methylated spirits is govern
12、ed by The Methylated Spirits Regulations,1983 (S.I.1983 No.252). It is not permissible to use duty-free ethanol, received under the provisions of the Alcoholic Liquors Duties Act1972, Section10, for purposes for which industrial methylated spirits is an acceptable alternative. 3.2 Acetone 3.3 A mixt
13、ure of ion-exchange resins, produced from a strongly acidic(H form) cation exchanger mixed with a strongly basic(OH form) anion exchanger in inverse proportion by mass approximating to their respective ion exchange capacities. Use10g of this mixed resin for products containing up to4%ethanol soluble
14、 ionic matter, and use an additional5g resin for each additional4%ethanol soluble ionic matter. Immediately before use wash the mixed bed resin, contained in a250mL conical flask, three times by swirling and decanting with twice its volume of ethanol(3.1) to remove water and any trace of ethanol-sol
15、uble contamination. NOTEReady prepared mixed bed resins are available commercially. 3.4 Methylene blue solution, 0.03g/L. Dissolve0.15g of methylene blue (CI52015) in100mL of water, then dilute2mL of this solution to100mL. 3.5 Chloroform 4 Apparatus Ordinary laboratory apparatus and the following ar
16、e required. 4.1 One-mark volumetric flask, 250mL, complying with BS1792. 4.2 Wide-mouthed, flat-bottomed flask, 250mL. 5 Procedure 5.1 Test portion Carry out an ethanol extraction in accordance with BS3762-3.5, by method1 or method2. Pipette100mL of the solution from the one-mark volumetric flask(4.
17、1) into the250mL conical flask containing the washed ion-exchange resin(3.3). 5.2 Determination Insert a magnetic follower, cover the flask with a watch glass, and begin to stir, avoiding any splashing. Continue stirring for20min. Decant the solution into the250mL one-mark volumetric flask(4.1) thro
18、ugh a12.5cm diameter filter paper(fast speed). Allow the solvent to drain thoroughly. Add20mL of the ethanol(3.1) to the conical flask and swirl. Filter, allowing the solvent to drain completely. Repeat with three more20mL portions of ethanol. Wash the filter paper with ethanol. Dilute to the mark w
19、ith ethanol. Check the resin as follows. Remove exactly5mL of the solution from the volumetric flask using a clean, dry pipette and without rinsing the pipette with the solution. Transfer approximately2mL of this aliquot portion to a test tube and discard the rest. Add10mL of water,1mL of the methyl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS3762371986ANALYSISOFFORMULATEDDETERGENTSQUANTITATIVETESTMETHODSMETHODFORDETERMINATIONOFTOTALNONIONICMATTERCONTENT

链接地址:http://www.mydoc123.com/p-543869.html