ASTM F3097-2015 Standard Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore Vacuum Excavation《通过最小幅度侵入的小口径真空开挖安装污水管外部清洁服务的标准实施规程.pdf
《ASTM F3097-2015 Standard Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore Vacuum Excavation《通过最小幅度侵入的小口径真空开挖安装污水管外部清洁服务的标准实施规程.pdf》由会员分享,可在线阅读,更多相关《ASTM F3097-2015 Standard Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore Vacuum Excavation《通过最小幅度侵入的小口径真空开挖安装污水管外部清洁服务的标准实施规程.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3097 15Standard Practice forInstallation of an Outside Sewer Service Cleanout through aMinimally Invasive Small Bore Vacuum Excavation1This standard is issued under the fixed designation F3097; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers installation methods, test methodsand required materials for
3、 the installation of an outside sewerservice clean out, by means of a small vacuum excavatedborehole. The utilization of this practice greatly reducesdisruption to the general public and requires minimal restora-tion.1.2 UnitsThe values stated in inch-pound units are to beregarded as standard. No ot
4、her units of measurement areincluded in this standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
5、of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C920 Specification for Elastomeric Joint SealantsD1600 Terminology for Abbreviated Terms Relating to Plas-ticsD2855 Practice for Making Solvent-Cemented Joints withPoly(Vinyl Chloride) (PVC) Pipe and FittingsD3034 Spec
6、ification for Type PSM Poly(Vinyl Chloride)(PVC) Sewer Pipe and FittingsF412 Terminology Relating to Plastic Piping Systems3. Terminology3.1 Unless otherwise indicated, definitions are in accor-dance with Terminology F412, and abbreviations are in accor-dance with Terminology D1600.3.2 Definitions o
7、f Terms Specific to This Standard:3.2.1 adhesive/sealantan elastomeric bonding agent de-signed to provide a water activated, leak resistant flexible bondbetween a PVC pipe saddle and a lateral sewer service pipe.3.2.2 borehole a small diameter vacuum excavated hole.3.2.3 cleanouta fitting located on
8、 a lateral sewer servicepipe having a vertical riser pipe extending therefrom to thesurface providing access to the lateral sewer service pipe.3.2.4 cleanout riser pipea section of pipe that is con-nected to the boss of a saddle and extends from the saddle tothe surface.3.2.5 coringthe process of re
9、motely cutting a hole throughthe crown of a sewer service pipe such that the coupon isretrieved to establish communication from a cleanout riser pipeand a lateral sewer service pipe.3.2.6 coupona disc shaped piece of the lateral sewerservice pipe produced by coring.3.2.7 lateral sewer service pipea
10、sewer pipe that connectsa building to a municipal, main sewer pipe in a lateral directionand collects sanitary waste or storm water.3.2.8 saddlea PVC saddle that encompasses more than50% of a lateral sewer service pipe where the side walls of thesaddle extend beyond the spring line of the host pipe.
11、 Thesaddle includes setoff tabs that allow for uniform distributionof the adhesive/sealant.3.2.9 setoff tabsProtruding tabs located on the undersideof the saddle one located on each side of the saddle boss for thepurpose of insuring a specific annulus between the host pipeand the saddle and a specif
12、ic layer thickness of adhesive/sealant.3.2.10 sondea device outfitted in a closed circuit videoinspection camera that emits a signal in subterranean pipelinesthat is traceable by use of a locating receiver at surface.4. Summary of Practice4.1 The process of installing a cleanout through a minimallyi
13、nvasive excavation begins with locating the 4 in. or 6 in. sewerservice lateral. This is accomplished by use of a CCTVoutfitted with a locatable sonde and vacuum excavating a smallborehole, providing access to the exterior surface of a lateral1This practice is under the jurisdiction of ASTM Committe
14、e F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved May 15, 2015. Published June 2015. DOI: 10.1520/F3097152For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
15、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1sewer service pipe. Once the lateral se
16、wer service pipe hasbeen exposed, a self-clamping saddle is prepared by applyinga specified amount of adhesive/sealant to the underside of thesaddle and a riser pipe is attached to the boss of the saddle. Theprepared saddle is lowered into the small diameter bore holeuntil it contacts the lateral se
17、wer service pipe; a downwardforce is applied to the riser pipe causing the side walls of thesaddle to spread and encompass more than 50-percent of thehost pipe. Surface restoration is minimal and in most cases isaccomplished the same day the cleanout is installed.5. Significance and Use5.1 This prac
18、tice is for use by designers and specifiers,regulatory agencies, owners, and inspection organizations whoare involved in the installation of a sewer service cleanout6. Components6.1 The saddle shall be formed as a semi-circle and shallencompass more than 180-degrees of the pipe circumference.The sad
19、dle shall have an inner diameter equal to the outerdiameter of the host pipe (see Fig. 1).6.2 The riser pipe shall be PVC pipe in accordance withSpecification D3034.6.3 Adhesive/Sealant shall be in accordance with Specifica-tion C920.6.4 The solvent cement shall be in accordance with PracticeD2855.7
20、. Tools Required for Installation7.1 Vacuum excavation unitmobile piece of equipmentthat supplies sufficient volume of vacuum necessary to exca-vate a vertical bore hole.7.2 Coring equipmentA suitable coring saw with an outerdiameter18 in. less than the inner diameter if the riser pipe witha cutting
21、 blade suitable for the specific pipe material on whichthe cleanout has been installed.7.3 Power headpower device that rotates the coring saw.7.4 Extension rodsextension shafts that connect the powerhead to the coring saw. Available in various lengths accordingto the depth of the service lateral pip
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF30972015STANDARDPRACTICEFORINSTALLATIONOFANOUTSIDESEWERSERVICECLEANOUTTHROUGHAMINIMALLYINVASIVESMALLBOREVACUUMEXCAVATION

链接地址:http://www.mydoc123.com/p-540027.html