ASTM F2699-2008 Standard Guide for Fences for Commercial and Public Outdoor Water Spray Play Areas《商业区和公共区室外喷水区 游乐区用围栏的标准指南》.pdf
《ASTM F2699-2008 Standard Guide for Fences for Commercial and Public Outdoor Water Spray Play Areas《商业区和公共区室外喷水区 游乐区用围栏的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2699-2008 Standard Guide for Fences for Commercial and Public Outdoor Water Spray Play Areas《商业区和公共区室外喷水区 游乐区用围栏的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2699 08Standard Guide forFences for Commercial and Public Outdoor Water Spray/Play Areas1This standard is issued under the fixed designation F 2699; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides the recommended minimum re-quirements for various types of fences for commercial andpublic outdoor water
3、 spray/play areas.1.2 This guide provides for the safety of occupants in waterspray/play areas or zones as it pertains to vehicular intrusion aswell as other participant intrusion, and for children contain-ment or entry/exit.1.3 This guide does not choose the product components forthe fence system,
4、the choice of which should be made by theoperators of the water spray/play area space and their specifi-cation writers or drafters based upon their determination of themerits of the products that could be used.1.4 The values stated in inch-pound units are to be regardedas the standard. The SI values
5、 stated in parentheses areprovided for information purposes only.1.5 This guide does not purport to address the aspect ofsafety within a water spray/play area or zone. It is theresponsibility of the user of this guide to establish appropriatesafety practices as related to the water spray/play area a
6、nddetermine the applicability of regulatory requirements prior touse.2. Referenced Documents2.1 ASTM Standards:2A 392 Specification for Zinc-Coated Steel Chain-LinkFence FabricA 491 Specification for Aluminum-Coated Steel Chain-Link Fence FabricF 537 Specification for Design, Fabrication, and Instal
7、lationof Fences Constructed of Wood and Related MaterialsF 552 Terminology Relating to Chain Link FencingF 668 Specification for Polyvinyl Chloride (PVC) andOther Organic Polymer-Coated Steel Chain-Link FenceFabricF 900 Specification for Industrial and Commercial SwingGatesF 964 Specification for Ri
8、gid Poly (Vinyl Chloride) (PVC)Exterior Profiles Used for Fencing and RailingF 1043 Specification for Strength and Protective Coatingson Steel Industrial Chain Link Fence FrameworkF 1083 Specification for Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence StructuresF 1345 Specificati
9、on for Zinc-5 % Aluminum-MischmetalAlloy-Coated Steel Chain-Link Fence FabricF 2049 Guide for Fences/Barriers for Public, Commercial,and Multi-Family Residential Use Outdoor Play AreasF 2408 Specification for Ornamental Fences EmployingGalvanized Steel Tubular PicketsF 2453/F 2453M Specification for
10、 Welded Wire MeshFence Fabric (Metallic-Coated or Polymer Coated) forMeshes of 6 in.23871 mm2 or Less, in Panels or Rolls,with Uniform MeshesF 2589 Specification for Ornamental Fences EmployingSteel Tubular Pickets2.2 NFPA Document:3National Electrical Code, NFPA70-1996 or current edition.2.3 ANSI/I
11、AF Documents related to water containments43. Terminology3.1 See Terminology F 552 for definitions of terms relatingto chain-link fencing.3.2 Definitions of Terms Specific to This Standard:3.2.1 fence, na type of barrier, which surrounds andobstructs access to the water area.3.2.2 grade, nthe finish
12、ed elevation at any specified pointof the ground or pavement outside the water area, examples,chain link, wood, PVC, ornamental, welded wire.3.2.3 outdoor, adjlocated outside of a completely en-closed building or other structure.3.2.4 water spray/play area or zone, na space for wateractivities that
13、can be controlled by the user or participant withwater that is sprayed, hosed, dumped from buckets, falls from1This guide is under the jurisdiction of ASTM Committee F14 on Fences and isthe direct responsibility of Subcommittee F14.10 on Specific Applications.Current edition approved Feb. 1, 2008. P
14、ublished February 2008.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protecti
15、on Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
16、 19428-2959, United States.overflow rims or other form of water sprays or that the userengages in without a control and that the egress or ingressshould be contained or protected.4. Summary of Guide4.1 This guide is based, in part, upon the premise that allwater areas are a potential source in which
17、 drowning, neardrowning and other injuries can occur. Such other man-madeand natural water sources are protected by other fence stan-dards; and that dry play areas are also protected by a fencestandard for the safety of the users within the area or zone andoutside of the area or zone that have intru
18、sions, interferences,conflicts, no containment or other situations, which can causelife threatening or debilitating conditions.5. Significance and Use5.1 This guide sets forth minimum standard requirementsfor use in local codes and ordinances relating to commercialand public water spray/play areas.5
19、.2 This guide does not have the effect of law, nor is itintended to supersede local codes and ordinances of a morerestrictive nature.5.3 This guide provides certain recommendations to assistthose who intend to provide protection against injuries orfatalities associated with any possible vehicle pass
20、age into, orpedestrian passage to or from a water spray/play area environ-ment by children. This would include, but not be limited to,state and local governments, model code organizations, build-ing code groups, and consumers. It is understood that theformat will vary depending upon the specific use
21、 and localconditions.6. Requirements6.1 HeightThe top of the interior fence shall be a mini-mum of 48 in. (1219 mm) above grade measured on the side ofthe fence that faces away from the water spray/play area. If thefence is mounted on top of a wall or berm, the top of the fenceshall be a minimum of
22、36 in. (914 mm) above the top of thewall or berm, provided the top of the fence is a minimum of48 in. (1219 mm) above grade. (See 3.2.2 for definition of“grade” specific to this guide). The top of the exterior perimeterfence shall be a minimum of 72 in. (1829 mm) from grade orwall.6.2 Visibility/Acc
23、essibilityThe fence shall be so designedand constructed that 50 % visibility and accessibility foremergencies from a designated supervising area outside thewater spray/play area to inside the water spray/play area.6.3 Continuous BarriersThat prevent vehicle intrusioninto such areas or zones that are
24、 in proximity to highways,streets and parking lots should supplement fences and shallconform to F 2049.6.4 Ground ClearanceThe maximum vertical clearancebetween grade and the bottom of the fence shall be 2 in.(51 mm) measured on the sides of the fence that faces awayfrom the water spray/play area. W
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26992008STANDARDGUIDEFORFENCESFORCOMMERCIALANDPUBLICOUTDOORWATERSPRAYPLAYAREAS 商业区 公共 室外 喷水 游乐区

链接地址:http://www.mydoc123.com/p-539289.html