ASTM F2638-2007 Standard Test Method for Using Aerosol Filtration for Measuring the Performance of Porous Packaging Materials as a Surrogate Microbial Barrier《使用气溶胶过滤测量替代微生物物障的疏松包装.pdf
《ASTM F2638-2007 Standard Test Method for Using Aerosol Filtration for Measuring the Performance of Porous Packaging Materials as a Surrogate Microbial Barrier《使用气溶胶过滤测量替代微生物物障的疏松包装.pdf》由会员分享,可在线阅读,更多相关《ASTM F2638-2007 Standard Test Method for Using Aerosol Filtration for Measuring the Performance of Porous Packaging Materials as a Surrogate Microbial Barrier《使用气溶胶过滤测量替代微生物物障的疏松包装.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2638 07Standard Test Method forUsing Aerosol Filtration for Measuring the Performance ofPorous Packaging Materials as a Surrogate MicrobialBarrier1This standard is issued under the fixed designation F 2638; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the aerosol filtration perfor-mance of p
3、orous packaging materials by creating a definedaerosol of 1.0 m particles and assessing the filtration effi-ciency of the material using either single or dual particlecounters.1.2 This test method is applicable to porous materials usedto package terminally sterilized medical devices.1.3 The intent o
4、f this test method is to determine the flowrate through a material at which maximum penetration occurs.The porous nature of some materials used in sterile packagingapplications might preclude evaluation by means of this testmethod. The maximum penetration point of a particular mate-rial could occur
5、at a flow rate that exceeds the flow capacity ofthe test apparatus. As such, this test method may not be usefulfor evaluating the maximum penetration point of materials witha Bendtsen flow rate above 4000 mL/min as measured byISO 56363.1.4 The values stated in SI units are to be regarded as thestand
6、ard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-
7、bility of regulatory limitations prior to use.2. Referenced Documents2.1 ISO Standard:2ISO 56363 Paper and BoardDetermination of Air Per-meance (Medium Range)Part 3: Bendtsen Method3. Terminology3.1 Definitions:3.1.1 challenge aerosola sufficient quantity of aerosolized1.0 m particles that enable ef
8、fective particle counting in thefiltrate aerosol.3.1.2 filtrate aerosolparticles that remain aerosolized af-ter passage through the test specimen.3.1.3 maximum penetrationthe highest percent concentra-tion of particles in the filtrate aerosol when a specimen is testedover a range of pressure differe
9、ntials or air flow rates.3.2 Abbreviations and Symbols:Symbol Unit DescriptionCSn Average particle count of the challenge aerosolwhen using a single particle counter (Method A).CFn Average particle count of the filtrate aerosol.CCn Average particle count of the challenge aerosol.CLRN Average particl
10、e count of the filtrate aerosol prior tocorrection for dilution.R % Percentage of particles from the challenge aerosolthat remain in the filtrate aerosol.RM% The calculated maximum of R.P1cm WC Pressure differential across a test specimen due tothe air flow required by the particle counter.P cm WC P
11、ressure differential across a test specimen.F L/m/cm2Air flow rate through the test specimen.F1L/m/cm2Air flow rate required by the particle counter whenmeasuring the filtrate aerosol.FML/m/cm2Air flow rate at which maximum penetration occurs.4. Safety4.1 The waste and the vacuum venturi vents for t
12、he testequipment described in this test method emit an aerosol ofpolystyrene particles and salt residues. These aerosols shouldbe exhausted from any enclosed environment or collected andfiltered to remove all particles.5. Summary of Test Method5.1 A porous packaging material test specimen is placed
13、ina sample holder in such a way as to create a filter between thechallenge and filtrate aerosols. On the challenge side of thesample holder, an aerosol of particles is presented to thesurface of the test specimen. An air flow is generated throughthe test specimen. A laser particle counter is used to
14、 monitorthe particle concentrations in the challenge and filtrate aero-sols. Particle concentrations will be measured over a range of1This test method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.15 onChemical/ Safe
15、ty Properties.Current edition approved Aug. 1, 2007. Published September 2007.2Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
16、2959, United States.flow rates in order to measure the percent penetration over therange of flow rates and determine the point of maximumpenetration.5.2 This test uses an aerosol of polystyrene latex particles(PSL) with a geometric mean particle diameter of 1.0 m anda standard deviation of less than
17、 0.05 m.5.2.1 A single particle counter may be used to sequentiallymeasure the challenge and filtrate aerosols or two particlecounters may be used to measure them continuously. Whenusing a single particle counter the challenge and filtrateaerosols will be sequentially measured for each test flow rat
18、e.The filtrate aerosol concentration is reported as the averageconcentration of the filtrate aerosol over a time period of 45 to60 s, beginning no sooner than 1 min from the start of thefiltrate aerosol measurement. The challenge aerosol concentra-tion is reported as the average concentration of the
19、 challengeaerosol over a time period of not less than 45 s, beginning nosooner than 1 min from the start of the challenge measurement.Challenge concentrations measured immediately before andafter each filtrate concentration measurement are averaged todetermine the challenge concentration for a given
20、 flow rate.5.2.2 When using two particle counters, the challenge andfiltrate aerosols are counted continuously by dedicated particlecounters. The challenge and filtrate aerosol concentrations arereported as the average concentration of the challenge orfiltrate aerosol over a time period of not less
21、than 45 s,beginning no sooner than 1 min after a change in flow rate.5.3 At the pressures used in this test, pressure differentialacross the sample and flow rate through the material aredirectly proportional. Pressure will be varied over a range thatwill ideally have at least two measurements at flo
22、w rates thatare higher and lower than the flow rate that demonstrates themaximum penetration.5.4 The reported results are the maximum penetration andthe flow rate at which it occurs.6. Significance and Use6.1 This test method has been developed as a result ofresearch performed by Air Dispersion Limi
23、ted (Manchester,UK) and funded by the Barrier Test Consortium Limited. Theresults of this research have been published in a peer-reviewedjournal.3This research demonstrated that testing the barrierperformance of porous packaging materials using microorgan-isms correlates with measuring the filtratio
24、n efficiency of thematerials.6.2 This test method does not require the use of microbio-logical method; in addition, the test method can be conductedin a rapid and timely manner.6.3 When measuring the filtration efficiency of porouspackaging materials a typical filtration efficiency curve is3“Definit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26382007STANDARDTESTMETHODFORUSINGAEROSOLFILTRATIONFORMEASURINGTHEPERFORMANCEOFPOROUSPACKAGINGMATERIALSASASURROGATEMICROBIALBARRIER

链接地址:http://www.mydoc123.com/p-539143.html